검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2023.05 구독 인증기관·개인회원 무료
        Our research team has developed a gamma ray detector which can be distributed over large area through air transport. Multiple detectors (9 devices per 1 set) are distributed to measure environmental radiation, and information such as the activity and location of the radiation source can be inferred using the measured data. Generally, radiation is usually measured by pointing the detector towards the radioactive sources for efficient measurement. However, the detector developed in this study is placed on the ground by dropping from the drone. Thus, it does not always face toward the radiation source. Also, since it is a remote measurement system, the user cannot know the angle information between the source and detector. Without the angle information, it is impossible to correct the measured value. The most problematic feature is when the backside of the detector (opposite of the scintillator) faces the radiation source. It was confirmed that the measurement value decreased by approximately 50% when the backside of the detector was facing towards the radiation source. To calibrate the measured value, we need the information that can indicate which part of the detector (front, side, back) faces the source. Therefore, in this study, we installed a small gamma sensor on the backside of the detector to find the direction of the detector. Since this sensor has different measurement specifications from the main sensor in terms of the area, type, efficiency and measurement method, the measured values between the two sensors are different. Therefore, we only extract approximate direction using the variation in the measured value ratio of the two sensors. In this study, to verify the applicability of the detector structure and measurement method, the ratio of measured values that change according to the direction of the source was investigated through MCNP simulation. The radioactive source was Cs-137, and the simulation was performed while moving in a semicircular shape with 15 degree steps from 0 degree to 180 degrees at a distance of 20 cm from the center point of the main sensor. Since the MCNP result indicates the probability of generating a pulse for one photon, this value was calculated based on 88.6 μCi to obtain an actual count. Through the ratio of the count values of the two sensors, it was determined whether the radioactive source was located in the front, side, or back of the probe.
        2.
        2022.10 구독 인증기관·개인회원 무료
        When the nuclear accident like the Fukushima is occurred, it is required to immediately determine the location of radioactive materials and their activities. Various studies related the unmanned technique to detect and characterize the contaminated area have been conducted. The Korea Institute of Nuclear Nonproliferation and Control (KINAC) has developed a new gamma detection system which consists of nine probes using a silicon photomultiplier (SiPM) and plastic scintillator. The probe is the small gamma detector designed to be carried and dropped near the accident area by the unmanned aerial vehicle. In this paper, we developed the improved design related to the angular dependence of the radioactive contamination detection system with the purpose of increasing the detection efficiency. The detection efficiency, radiation shielding and back-scattering varies depending on the direction of incidence of radiation because the probe has vertical structure of consisting scintillator, photomultiplier, and electric circuits. That is, when the experimental conditions are same except the direction of gamma probe, the result of measurements is different. It causes errors in measuring the radioactivity and location of the radioactive source. Since the direction of the probe is arbitrarily determined during the deployment of the probe through the unmanned aerial vehicle, it is considered changing the design of the scintillator from a conventional 1.0" × 1.0" Φ cylindrical shape to a 1.0" Φ spherical shape. In case of using the spherical scintillator, it is confirmed that angular dependence was reduced through MCNP simulation. The difference in the measurement depending on the direction of the probe could be reduced through additional structure design. Finally, we hope that the developed detection system which has the probes with spherical shape of scintillator can measure the radioactivity and location of the radioactive source in a range of about 100 × 100 m2 by measuring for at least 5 minutes. The field test at Fukushima area will be carried out with JAEA members in order to prove the feasibility of the new system.