We plan to produce a faint source catalogue from the AKARI mid-infrared (IR) all-sky diffuse maps. In the publicly-available AKARI mid-IR point source catalogue (PSC), sources were extracted from single- scan images, and conrmed by using the other scan images. By stacking multiple scan images, we can detect fainter sources which are not listed in the PSC. We optimized the source extraction process using a 6◦ 6◦ area around the star-forming region, Cepheus B. Then, we divided the all-sky data into three seasonal images, and checked the positions and the uxes of the detected sources on the images. As a result, our new source extraction method works well; 90% of the sources are also identied in the WISE catalogue. In this method, we obtain the detection limit twice deeper than that of the PSC. The number of sources increases by a factor of 2, as compared with the PSC.
This study is a duralumin and applying heat to the STS-wide measurement range is used, the surface temperature by using the temperature of studying the non-destructive testing of a new paradigm to estimate the position and size of a structure defect purpose. STS and duralumin which has a structure defect is applied a heat by a heater. Its difference of STS and duralumin surface temperature is measured using IR thermography. The estimated result of the STS and duralumin experiment and that of theoretical analysis of PDE are compared and analyzed to diagnose the STS and duralumin defect. Moreover, this study can save time and money and improve accuracy contrast to the existing ultrasonic NDE experiment. In addition, the new paradigm of NDT/NDE by reverse-engineering is going to be valid if the data of thermal analysis and temperature distribution from the specifications of many materials is accumulated and verified. In this study, the average surface temperature of the STS in the same heating condition was 4.53 ° K higher than that of duralumin and both of the surface temperature showed an inflection point in the defect 2.5mm.The maximum surface temperature difference was formed on the 2.5mm, and the study proves its reliability because the average surface temperature of the STS and duralumin was 0.74°K, 0.45°K higher than the theoretical surface temperature.
콘크리트 구조물의 안전진단을 위해 충격반향기법(Impact Echo method, IE)과 충격응답기법(Impulse Response method, IR)을 이용하여, 콘크리트 모형 하부의 공동 유무에 따른 탐사 결과를 분석하였다. 콘크리트 모형은 순수 콘크리트 부분과 철근+콘크리트 부분으로 나누고, 공동의 유무에 따라 각 기법의 적용에 의한 반응 변화를 관찰하였다. 이 연구에 앞서 수행한 GPR과 IE 및 IR 기법의 복합 적용 결과, IE 및 IR 기법이 철근의 영향을 크게 받지 않고 공동존재 여부에 따른 반응이 비교적 잘 나타나는 것으로 파악되었다. 본 연구에서는 선행 연구 결과를 토대로 IE와 IR 기법의 활용도를 높여서 보다 정확한 콘크리트 구조물의 안전진단 기법을 개발하고자 하였다. GPR과 같은 비파괴 조사 기법과 달리, IE 및 IR 기법은 측정이 이루어지는 위치를 정확히 알 수 있어 각 측점의 콘크리트 두께와 하부 공동의 반응을 보다 정확히 파악할 수 있는 장점이 있다. 연구 결과, IE 기법에서는 공진주파수보다 낮은 저주파수에서 나타나는 작은 피크 구간이 공동에 의한 반응으로 보이며, IR 기법에서는 주파수에 따른 운동성(mobility)과 동적 강성도(dynamic stiffness)의 변화를 통해 공동의 유무를 확인할 수 있었다. 이 연구에서 제안한 방법은 콘크리트 구조물의 보수 보강에 활용될 수 있을 것으로 예상된다.