검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Among the Fire Protection in the interior representative case are spray coat, board, Paint. Intumescent paint has been developed that price competitiveness manufactures and Fire-resistances certificate was verified by experiment. Recent three-hour fire resistance performance developed Intumescent paint is applied as a high-rise, and major structures designed according to the refractory needs to be more efficient. However, domestic and outside the thermal properties of Intumescent paint materials are not proposed. Meanwhile, Intumescent paint in fire is built char layer since the 500∼60 0℃ and middle layer is formed by the decuple intumescent char more then cover thickness at room temperature. It is cut temperature flow off to the steel surface. Nonetheless, Bond Strength of steel and paint deprive as the intumescent char increases. and then steel surface are exposed to flame instantaneously. In this study, intumescent char estimate according to structural parameter(Fire resistance, cover thickness, shape ratio).
        4,000원
        2.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Among the Fire Protection in the interior representative case are spray coat, board, Paint. Intumescent paint has been developed that price competitiveness manufactures and Fire-resistances certificate was verified by experiment. Recent three-hour fire resistance performance developed Intumescent paint is applied as a high-rise, and major structures designed according to the refractory needs to be more efficient. However, domestic and outside the thermal properties of Intumescent paint materials are not proposed. Meanwhile, Intumescent paint in fire is built char layer since the 500∼60 0℃ and middle layer is formed by the decuple intumescent char more then cover thickness at room temperature. It is cut temperature flow off to the steel surface. Nonetheless, Bond Strength of steel and paint deprive as the intumescent char increases. and then steel surface are exposed to flame instantaneously. In this study, intumescent char estimate according to structural parameter(Fire resistance, cover thickness, shape ratio).
        3,000원
        3.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Other countries(USA, Europe) have performed the fire resistance design of buildings by the alternative performance design methods, which are based on fire engineering theories. However, in Korea, the process on the alternative fire resistance performance design has only suggested without any applications for real steel structures. Therefore, In the case of steel structures stagnant research on refractory measures face difficulties in introducing fire resistance design. In this study, first of all, Intumescent paint was analyze the thermal properties(thermal conductivity, specific heat and density). In Sequence, using the section factor by H-standard section propose of section concrete filled steel tube and hollow. finally presents a reasonable thickness Intumescent paint takes time to target performance of the proposed cross-section steel tube.
        4,000원