This study examined the effects of socket flexion angle in trans-tibial prosthesis on stump/socket interface pressure. Ten trans-tibial amputees voluntarily participated in this study. F-socket system was used to measure static and dynamic pressure in stump/socket interface. The pressure was measured at anterior area (proximal, middle, and distal) and posterior area (proximal, middle, and distal) in different socket flexion angles (5°, 0°, and 10°). Paired t-test was used to compare pressure differences in conventional socket flexion angle of 5° with pressures in socket flexion angles of 0° and 10° (α=.05). Mean pressure during standing in socket flexion angle of 10° decreased significantly in anterior middle area (19.7%), posterior proximal area (10.4%), and posterior distal area (16.3%) compared with socket flexion angle of 5°. Mean pressure during stance phase in socket flexion angle of 0° increased significantly in anterior proximal area (19.3%) and decreased significantly in anterior distal area (19.7%) compared with socket flexion angle of 5°. Mean pressure during stance phase in socket flexion angle of 10° decreased significantly in anterior proximal area (19.6%) and increased significantly in anterior distal area (8.2%) compared with socket flexion angle of 5°. Peak pressure during gait in socket flexion angle of 0° increased significantly in anterior proximal area (23.0%) compared with socket flexion angle of 5° and peak pressure during gait in socket flexion angle of 10° decreased significantly in anterior proximal area (22.7%) compared with socket flexion angle of 5°. Mean pressure over 80% of peak pressure (MP80+) during gait in socket flexion angle of 0° increased significantly in anterior proximal area (23.9%) and decreased significantly in anterior distal area (22.5%) compared with socket flexion angle of 5°. MP80+ during gait in socket flexion angle of 10° decreased significantly in anterior distal area (34.1%) compared with socket flexion angle of 5°. Asymmetrical pressure change patterns in socket flexion angle of 0° and 10° were revealed in anterior proximal and distal region compared with socket flexion angle of 5°. To provide comfortable and safe socket for trans-tibial amputee, socket flexion angle must be considered.
뇌 질환과 두경부 검사에서 전산화단층촬영의 선속 경화현상이 없는 자기공명영상이 조직의 높은 대조 도와 우수한 분해능의 영상을 획득하는 검사 방법으로 인식되고 있지만 구강 내 금속 이식물이 있는 경우는 자화율 인공물(magnetic susceptibility artifact)이 발생되어 영상 진단에 장해 요소가 된다. 따라서 본 연구는 자기공명영상에서 치아 임플란트와 보철에 의한 인공물 감소 방안을 강구하고자 한다. 자기공명영상에서 임플란트에 의한 인공물 발생은 GE 기법에서 TE가 짧을수록 신호 크기가 증가하였고, 물의 온도 변화에서는 일관성이 없게 나타났다. SE 기법에서도 공기보다 물의 신호 크기가 전반적으로 높았지만, 신호 대 잡음비는 공기와 온도에 의한 차이가 없었다. EPI 기법에서는 공기보다 물이 있을 때 정량적, 정성적으로 인공물이 적게 발생한 영상을 얻을 수 있었고, 특히 물 온도 20°와 30°에서 신호 대 잡음비가 가장 높게 측정되었다. 결론적으로 EPI 기법에서 물 온도 20°와 30°의 물주머니를 이용하여 뇌 확산강조영상을 획득하면 임플란트와 보철물에 의한 자화율인공물이 감소되어 보다 진단적 가치가 있는 영상을 획득할 수 있을 것으로 사료된다.