검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, numerical analysis was performed for the purpose of analyzing the flow characteristics and performance according to the change in the inflow hydrogen temperature and differential pressure of the receptacle of the hydrogen charging system. The pressure distribution and turbulent kinetic energy in the filter area were analyzed by changing the outlet pressure condition under the inlet hydrogen temperature condition, and the flow velocity change at the outlet was compared and analyzed. As a result of the analysis, as the differential pressure decreased, the flow rate at the outlet of the receptacle decreased by up to about 70% at the 2.86 MPa condition compared to the 1.86 MPa condition, and the mass flow rate decreased by about 56.5% at the maximum. It was found that the standard CV performance was not satisfied when the differential pressure at the inlet and outlet was 1.12 MPa or less under the 363K temperature condition.
        4,000원