검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the demand for reliability verification is increasing while designing and manufacturing molds using injection molding computer aided engineering(CAE). When performing flow analysis verification, a spiral mold is produced and compared with CAE. Because of the spiral shape, we needed a comparative evaluation with the flow distance of products with different forms. So, we compared the weight and flowed length using CAE. Variables are the change in the width of the spiral shape and the shape of the bar and plate. When the width of the spiral shape is 23mm rather than 15mm, the flow distance flows 30∼70mm more, with a maximum difference of 13%. As a result of comparing the spiral shape and the long square shape with the same width, the spiral shape had a flow distance of 60 to 105mm further, and a difference of up to 28% was found. As a result of comparing the plate shape and the spiral shape with a 15mm width product, the spiral shape has a flow distance of 310∼380mm further, and a difference of up to 82% is different.
        4,000원