One of the important advantages of Thermosonics is that it can be applied to complex structures such as a turbine blade as a convenient and quick screening test method. For a reliable thermosonic test, the vibrational characteristics of the system comprising the tested structure and the clamp at ultrasonic frequency range should be identified. Therefore, this study presented the analysis results of frequency response functions and mode shapes of the turbine blade and clamp system and investigate the possibility of the reliable excitation system for the thermosonic test.