Steel plate concrete (SC) composite structure is now being recognized as a promising technology applicable to nuclear power plants as it is faster and suitable for modular construction. It is required to identify its dynamic characteristics prior to perform the seismic design of the SC structure. Particularly, the damping ratio of the structure is one of the critical design factors to control the dynamic response of structure. This paper compares the criteria for the damping ratios of each type of structures which are prescribed in the regulatory guide for the nuclear power plant. In order to identify the damping ratio of SC shear wall, this study made SC wall specimens and conducted experiments by cyclic lateral load tests and vibration tests with impact hammer. During the lateral loading test, SC wall specimens exhibited large ductile capacities with increasing amplitude of loading due to the confinement effects by the steel plate and the damping ratios increased until failure. The experimental results show that the damping ratios increased from about 6% to about 20% by increasing the load from the safe shutdown earthquake level to the ultimate strength level.
비틂시험에서 전단탄성계수와 감쇠비에 상응하는 변형률 산정의 복잡성은 여러 방법에 의하여 해결되어 왔다. 특히, 수정 등가반경법은 공진주/비틂전단 시험의 모든 변형률 영역에서 변형률에 따른 등가반경비 곡선을 보다 효과적으로 나타내는데 적합하다. 감쇠비 산정시 수정 등가반경법을 쌍곡선 모델, 수정 쌍곡선 모델, 램버그오스굿 모델등에 적용시켜 보았다. 연구결과는 감쇠비 산정시 재래식 등가반경법에 의한 하나의 등가반경 수치를 사용하는 것은 적절치 않다는 것을 보여주었다. 이력감쇠뿐 아니라 미소변형률 영역에서의 흙의 감쇠 현상을 고려하기 위하여 새로운 모델이 개발되었고, 이러한 두 가지 복합감쇠에 상응하는 변형률 산정시 부가적 조정이 필요한지 검토해 보았다.