In Korea, most nuclear power plants were designed based on the design response spectrum of Regulatory Guide 1.60 of the NRC. However, in the case of earthquakes occurring in the country, the characteristics of seismic motions in Korea and the design response spectrum differed. The seismic motion in Korea had a higher spectral acceleration in the high-frequency range compared to the design response spectrum. The seismic capacity may be reduced when evaluating the seismic performance of the equipment with high-frequency earthquakes compared with what is evaluated by the design response spectrum for the equipment with a high natural frequency. Therefore, EPRI proposed the inelastic energy absorption factor for the equipment anchorage. In this study, the seismic performance of welding anchorage was evaluated by considering domestic seismic characteristics and EPRI's inelastic energy absorption factor. In order to reflect the characteristics of domestic earthquakes, the uniform hazard response spectrum (UHRS) of Uljin was used. Moreover, the seismic performance of the equipment was evaluated with a design response spectrum of R.G.1.60 and a uniform hazard response spectrum (UHRS) as seismic inputs. As a result, it was confirmed that the seismic performance of the weld anchorage could be increased when the inelastic energy absorption factor is used. Also, a comparative analysis was performed on the seismic capacity of the anchorage of equipment by the welding and the extended bolt.
원전 격납건물은 내진 안정성을 확보하기 위해 설계단계에서 여유나 보수성을 부여하게 된다. 원전 구조물의 내진성능 평가는 이러한 여유나 보수성을 배제한 실질적인 성능 및 응답을 기준으로 평가하게 된다. 본 연구에서는 내진성능 평가에 고려되는 구조물의 성능 및 응답관련 계수들 중 그 기여도가 비교적 큰 비탄성 에너지 흡수계수의 산정방법에 대한 비교를 수행하였다. 또한 각종 방법에 따라 산정된 비탄성 에너지 흡수계수에 따른 HCLPF(high confidence of low probability of failure)값의 변화를 분석하였다. 연구결과 원전 격납건물의 비탄성 에너지 흡수계수는 1.5~1.75로 나타났다. 구조물의 내진성능을 명확히 평가하기 위해서는 먼저 구조물의 비선형 거동 및 연성도를 정확히 평가하여야 함을 알 수 있다.