검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 59

        41.
        2018.10 서비스 종료(열람 제한)
        The durability of the steel structure can be affected by atmospheric corrosion environments as temperature, humidity, airborne salt etc.. However, atmospheric corrosion environments can be locally changed depending on structural condition and shape. To estimate the local atmospheric corrosion environments depending on structural member exposed to the marine environment, corrosion level of structural member in steel bridge was examined from exposure tests.
        42.
        2018.10 서비스 종료(열람 제한)
        Steel water gate can be vulnerable to corrosion problem, since it is generally contacted with water or maintained with relatively high humidity condition. In this study, to evaluate the level of corrosion damage of water gate, corrosion exposure test was conducted using monitoring steel plate and monitoring sensor in actual steel water gate. From exposure test results, corrosion rate and corrosion environment were examined depending on the height or the structural type of water gate.
        43.
        2018.10 서비스 종료(열람 제한)
        This study examined lateral load behaviors of partially grout filled steel tube from structural analysis. To evaluate structural resistant behaviors of partially grout filled steel tube, Nonlinear FE analysis model of partially grout filled steel tube was considered using ABAQUS program. From FE analysis results, grout filling effect and thickness effect of steel tube on the lateral load behaviors were compared.
        44.
        2018.05 서비스 종료(열람 제한)
        국제적으로 런던협약에 의하여 2013년 이후 음폐수의 해양 투기가 금지되어 육상에서의 처리가 시급한 실정이다. 이에 따라 국내외에서 유기성 폐기물의 혐기성 소화를 통한 부피 저감과 에너지화에 대한 연구가 활발하게 진행되고 있다. 이에 대하여 독일 등 유럽국가와 중국 등이 유기성 폐기물을 이용한 혐기성 소화가 활발히 진행되어오고 있으며, 해외의 혐기성 공법으로 Dranco, Valorga, SEBAC, Schwarting 공법 등이 있다. 국내에는 이러한 공법을 기반으로 한 혐기성 소화시설이 적용되어 가동 중에 있으나 해외의 인정받은 공법 임에도 국내에 적용된 시설에서의 운전상의 미숙 문제나 유기성 폐기물 성상 차이에 의한 소화 효율의 저하 및 가동 중지 등 운전상에 문제가 발생하고 있어 국내 음폐수 특성에 맞는 공법과 운전 방법에 관한 연구가 필요하다. 이에 따라 본 연구에서는 음폐수의 처리에 대한 방안 마련을 위하여 혐기성 소화 공법 중 독일의 Schwarting 공법을 응용하였다. 기존 다공판이 설치된 내부 구조에 층 분리 효과를 더 강화하여 혐기성 소화를 촉진하고자 다공판을 추가하여 이중으로 엇갈린 다공판이 설치된 소화조를 설계하여 비교하는 실험을 진행하였다. 실험에 사용된 시료는 D시에서 발생되는 음폐수를 대상으로 하였으며, 혐기성 미생물의 식종은 D시의 혐기성 소화조의 미생물을 활용하여 독일의 Schwarting 공법이 응용된 공법의 효율성을 검토하고자 하였다.
        45.
        2018.04 서비스 종료(열람 제한)
        The maintenance cost is rapidly increasing due to the increased of infrastructures such as railway and port etc., it is necessary management method of facility for measures and extend life. In the case of international infrastructure, in order to asset management to reasonably and effectively, asset management systems were developed for the management of facilities in various countries such as Australia and Canada etc. In this study, to develop the asset management process, the question investigation was conducted on maintenance site personnels for maintenance of the steel structure.
        46.
        2018.04 서비스 종료(열람 제한)
        For steel structure, corrosion problem can be a major maintenance area. Even with the same steel structure, corrosion damage can be changed depending on the location and form of thes structural member. In this study, rherefore, In order to evaluate the relative corrosion enviornmnet depending on the installed condition of the structural steel member, the corrosion deterioration environment was monitored for the large-size steel frame structure.
        47.
        2018.04 서비스 종료(열람 제한)
        Corrosion durability of steel member can be related to its installed environmental conditions such as relative humidity, rainfall, atmospheric temperature, and air pollution(SO2, chloride). Also its installed environmental condition may differ depending on the shape of structural member. Therefore, In this study, to evaluate the difference in the corrosion damage according to the installation environment of steel structural members, outdoor exposure test was carried out from attaching unpainted monitoring plate and atmospheric corrosion monitoring sensor for actual steel bridge with various structural detail.
        48.
        2018.04 서비스 종료(열람 제한)
        This study examined structural behaviors of grout filled composite steel tube member, since grout-filled steel tube can improve its structural load resistance from enhancing strength, stiffness, and confining effect. To evaluated the effect of grout filling in the steel tube on its structural behaviors and strength, grout-filled steel tube specimens were fabricated and lateral loading tests were conducted. From lateral loading tests, their lateral loading resistance and stiffness were examined.
        49.
        2017.09 서비스 종료(열람 제한)
        Steel structures have been prevented from corrosion damage using by paint coating. The durability of paint coating can be changed by installed environment condition of steel structures. In this study, thus, deterioration test of paint coating was conducted for various environmental condition. Deterioration levels of paint coating specimens exposed by each artificial environment were examined from visual inspection.
        50.
        2017.09 서비스 종료(열람 제한)
        Recently, steel has been very frequently chosen in building many civil infra-structures including bridges due to its several beneficial advantages as compared to concrete structures. However, for the most cases, damage such as section reduction, that is resulted from corrosion, was natural and inevitable. Therefore, it becomes very important to evaluate the structural safety and to estimate the life for the worst cases. In this study, the corrosion behaviors of mock-up specimen with box girder were examined by visual inspection.
        51.
        2017.04 서비스 종료(열람 제한)
        Visual inspection has generally been applied to examine the coating deterioration. However, it was difficult to evaluate an anti-corrosion performance of paint film. In this study, thus, to quantitatively evaluate an anti-corrosion performance of paint film under various corrosion enviornent, change in the impedance paint coating was evauated using EIS (Electrochemical Impedance Spectroscopy).
        52.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        Visual inspection has generally been applied to examine the coating deterioration. However, it was difficult to evaluate an anti-corrosion performance of paint film. In this study, thus, to quantitatively evaluate an anti-corrosion performance of paint film under various corrosion enviornent, change in the impedance paint coating was evauated using EIS (Electrochemical Impedance Spectroscopy).
        53.
        2016.10 서비스 종료(열람 제한)
        To properly maintain steel structures, it is important to investigate the corrosivity of structural member. In this study, atmospheric exposure tests were carried out for 1 year using monitoring steel plates (MSP). In addition, atmospheric corrosion environment were also monitored by temperature and humidity sensor, corrosion monitoring (ACM) sensors, etc.
        54.
        2016.06 KCI 등재 서비스 종료(열람 제한)
        스크린 클라이밍은 스크린 스포츠의 하나로 컴퓨터 시스템에 의해 내용이 인공암벽에 투사되며 사용자와의 상호작용에 의해 진행된다. 본 논문에서는 어린이의 발달과정과 스포츠 클라이밍에 대한 동기부여에 초점을 맞추어 고대동굴탐험을 소재로 한 스크린 클라이밍 게임을 구현하였다. 게임의 내용은 프로젝터로 인공암벽에 투사하며, 사용자와의 상호작용은 키넥트의 뎁스 정보를 이용해 사용 자의 입력을 받음으로써 이루어진다. 이 게임은 어린이 대상 전시 행사에서 높은 관심을 보였으며, 앞으로 추가적인 스크린 클라이밍 게임 구현이 이루어져야 한다.
        55.
        2016.04 서비스 종료(열람 제한)
        In this study, degradation due to the durability of the coating to reduce the check for to determine the deterioration of the durability coating was in parallel to outdoor exposure test and the salt spray test on the marine environment. weatherability paint coating was electrochemical measured using EIS (Electrochemical Impedance Spectroscopy) to evaluate durability. The purpose of the study was to compare the reduced durability of the paint coating.
        56.
        2015.10 서비스 종료(열람 제한)
        In this study, Impedence of bridge paint coating was measured using EIS(Electrochemical Impedance Spectroscopy) to evaluate durability of paint coating depeding on coating thickness. Thus, paint coating specimens with different paint thickness were used. From impedence mesearment, the durability of paint coating was compared.
        57.
        2015.10 서비스 종료(열람 제한)
        For steel structure, corrosion damage should be considered because it is related to durability and structural performacne of steel structure. In this study, therefore, compressive loading tests of inclined steel members were conducted to examine change in the compressive strength depending on corrosion damage applied by mechanical process. From loading tests, compressive behavior and change in structural capacity of inclined steel members with corrosion were compared.
        58.
        2009.02 KCI 등재 서비스 종료(열람 제한)
        본 연구는 게임을 구성하는 핵심적인 구성 요소인 규칙을 특성에 따라 단계별로 분류하고 각 규칙 단계의 성립 근거와 개념을 정의한다. 이러한 정의를 바탕으로 게임 규칙의 변화 과정을 분석하고 게임 규칙이 진화를 통해서 발전해 나간다는 점을 확인한다. 디지털 게임 규칙의 변화 구조는 환경에 따라 이루어지는 생물의 진화 경로와 같은 구조를 가진다. 이러한 새로운 관점에서 바라보는 이 연구를 통해서 게임 규칙의 진화와 생물의 진화 경로의 구조적 유사성을 살펴본다. 또한 디지털 게임 규칙이 진화하는 과정을 새로운 시각을 통해서 분석하고 개념화하고자 한다. 나아가 이 연구를 바탕으로 게임을 새로운 학문적 대상으로서 재발견하고자 한다.
        1 2 3