        1.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Radiant tubes heat exchangers are critical components that facilitate the heat transfer process to steel in an annealing furnace, and it addresses several engineering problems, such as thermal stress and mechanical failure due to long-term thermal cycling, which can significantly affect the longevity of the tubes and maintenance requirements. In this study, we used commercial software (ANSYS) to simulate the thermal stress and deformation of radiant tubes subjected to extreme thermal conditions and pressure loads. We evaluated both thermally induced deformation and creep deformation, which is a time-dependent deformation under constant stress over the long term. The results showed that uneven temperature conditions and pressure loads lead to significant deformation and potential failures. To mitigate these engineering challenges, we also tested several designs that include supporting brackets. This study provides valuable insights for designing radiant tube heat exchangers in annealing furnaces to extend their lifespan and ensure system safety.
        4,000원
        2.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 2019년에서 2021년까지, 매년 2월에서 5월 동안 대전광역시 6개 지점(기준지역 1곳 포함)의 기 온 데이터를 바탕으로 COVID-19로 인한 인간 활동의 감소가 대전 지역의 도시열섬강도에 미친 영향에 대하여 분석하 였다. 관측 지점에 따라 차이는 있으나 도시열섬강도는 COVID-19 전인 2019년에 비해 2020년과 2021년에 약 20% 이상 감소되었다. 인간 활동 감소는 야간의 도시열섬을 증가시키고 주간의 도시열섬을 감소시켰다. 그 결과 도시열섬강 도의 일변동 폭은 지점에 관계없이 2019년에 비해 2020년 및 2021년 모두 약 20% 이상 증가하였다. 도시열섬강도 감 소는 풍속과 같은 자연적 요인 및 사회적 거리두기 단계와는 큰 관련성이 없는 것으로 보인다. 반면에 COVID-19 이후 시행된 사회적 거리두기 및 확연히 감소된 대기오염물질과 관계가 있는 것으로 나타났으며, 특히 NO2와 가장 유의미한 상관관계를 보였다.
        4,300원
        5.
        1994.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the unit processes in the typical water treatment plant, which need to be expanded because the water demand is over the existing water treatment capacity in the near future, were carefully examined to upgrade the water treatment plant. The models were installed in the fields as a distorted model based upon the hydraulic similitudes. The models having the constant discharge ratio in the unit processes between the model and the prototype were installed as two units to compare the treatment efficiencies. The capacity of the individual unit, which is a model of the prototype of $250,000m^3/day$ capacity, was $24m^3/day$. In the mixing and flocculation experiments, the mixing intensity of flocculators G was selected as the main experimental item. The optimal mixing intensities G, which are 65/sec for experimental discharge of $1m^3/hr$ and 85/sec for experimental discharge of $1.3m^3/hr$, are identified based upon the comparison the relative turbidity removal efficiencies. Also, the outlet weir loading was selected as the main experimental item in the sedimentation process. Through the continuous experiments with the main experimental items of the mixing intensity of flocculators G and the outlet loading of the weir in the sedimentation basin, about 20% upgrading compared to the existing water treatment capacity was obtained.
        4,000원
        6.
        2011.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 현재 신교통 수단으로 연구 중인 바이모달 트램의 전용 교량을 개발하는데 있어 바이모달 트램 운행 특성을 고려한 실물크기의 중공화된 프리캐스트 바닥판을 새롭게 설계․제작하여, 신뢰성 있는 비선형 유한요소해석 프로그램(RCAHEST)을 통한 해석 결과와의 비교․분석을 바탕으로 적합성과 타당성을 검증하였다. 하중 재하 위치를 변수로 실험을 수행하여 설계 하중에 비하여 약 8∼9배의 충분한 안전율을 확보하고 있음을 확인하였으며, 본 연구에서 적용한 재료적 비선형성을 고려한 비선형 유한요소해석 프로그램을 통한 해석 결과 역시 콘크리트의 균열 발생 및 철근의 항복을 포함한 파괴시까지의 극한 거동 특성을 비교적 적절히 평가하고 있음을 알 수 있다.