검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 49

        1.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to the rapid growth of electrical vehicle and portable electronics markets, huge amount of the rare earth elements (REEs) and lithium have been required for the manufacturers globally. Moreover, after life time of the battery pass, the waste batteries containing valuable metal resources should be recycled due to competitions between the countries who manufacturing the batteries. Therefore, the REEs and lithium recoveries from the e-waste and wastewaters become issue recently. However, the commercialized technology for the valuable metal recovery is limited. In this study, the uses of the REEs and other valuable metal resources such as lithium, uranium, and gold and there recoverying methods according to the different water conditions were investigated and summarized. Moreover, the possible expectations and suggestions for the future application of the valuable resource recovery were conducted as a review.
        4,000원
        2.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 ‘설향’ 딸기를 두 작기(2020-2021년, 2021 -2022년)에 걸쳐 재배하면서 외부 광환경과 생육도일온도 가 작물 생산량에 미치는 영향을 분석하였다. 2년 동안 온실 내 환경 관리, 양액 관리 등은 동일하게 하였다. 재배기간 중 주 간의 온실 온습도는 두 작기에서 유사하게 관리되었고, 야간 의 온습도는 통계적으로 차이가 있었으나 작물 생육 범위를 벗어나지 않았다. 일사량은 9월과 10월에 첫 번째 작기의 일 평균 일사량이 많아 누적일사량도 많았으며, 11월부터는 2월 까지는 두 번째 작기의 일사량, 3월에는 다시 첫 번째 작기의 일사량이 많은 것으로 나타나 1월부터의 누적일사량은 두 번 째 작기에서 많은 것으로 나타났다. 딸기의 최적 일장 조건인 8시간 이상의 일장이 나타난 일은 두 작기 간 큰 차이가 없었고, 변화 양상은 누적일사량의 변화와 유사하게 나타났다. 누 적일사량과 생육도일온도는 상관관계가 커 생육도일온도가 딸기의 생산량과 당도에 미치는 영향을 조사해 본 결과의 초 기의 누적일사량과 생육도일온도가 적었던 두 번째 작기에서 초기 수확량은 적었으나 누적일사량 및 생육도일온도가 증가 함에 따라 후기에 수확량이 첫 번째 작기보다 많았으며 잠재 적 최대 생산량도 큰 것으로 나타났다. 당도는 생육도일온도 가 증가함에 따라 감소하였으며, 이는 촉성딸기의 특성으로 판단된다. 추후 연구를 통해 단순 수확량뿐만 아니라 작물 생 육, 꽃눈분화 및 출뢰시기를 조사, 분석하여 생육도일온도가 작 물 생육에 미치는 영향을 다각도로 분석하는 연구도 필요하다 고 판단된다.
        4,000원
        3.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 고온기 원예작물의 안정 생산을 위해 대형 단동하우스 ‘사계절하우스’를 파프리카 재배에 활용 시 시설 내부 기상 환경 및 파프리카 품종별 생육, 수량, 품질 등을 분석하고 근권냉방 효과 등을 구명하여 파프리카 재배환경 조건을 최적화 하기 위한 기초자료로 사용하고자 수행하였다. 정식 후부터 재배 종료 시점(2020년 5-11월)까지 시설내 평균 적산광량은 12.7MJ·m -2 d -1로, 온실외부의 평균 광량인 14.1MJ·m -2 d -1의 90% 수준으로 나타났다. 일 년중 가장 기온이 높은 7-8월의 온실내 24시간 평균온도는 외기보다 3.04℃ 낮았고, 장마가 끝난 8월 12일 이후에는 평균 4.07℃ 낮게 나타났다. 시설 내 포그 냉방 가동(6월 13일) 이전 일평균 상대습도는 최저 40% (주간 20%) 수준까지 떨어져 작물재배에 적합하지 않은 상태였으나 포그를 가동한 이후 주간 상대습도는 70-85% 수준으로 증가된 것으로 나타났다. 평균 수분부족분(humidity deficit)은 포그 공급전에는 최고 12.7g/m 3 까지 상승하여 매우 건조한 조건이었으나, 포그 공급 후 고온기(7-8월)에 평 균 3.7g/m 3으로 감소하였고, 저온기(10-11월)로 갈수록 다시 증가되는 경향이었다. 주간 잔존 CO2 농도는 전체 재배기 간동안 평균 707ppm으로 나타났다. ’20년 7월 27일부터 11월 23일까지 수확한 파프리카의 품종별 상품수량(kg/10a)은 주황색 품종 ‘DSP-7054’과 황색 품종 ‘Allrounder’이 각각 14,255kg/10a와 14,161kg/10a로 다른 품종에 비해 높았고, 다음으로 주황색 ‘K-Gloria orange’, 황색 ‘Volante’, 적색 ‘Nagano’ 품종 순으로 나타났다. 사계절하우스에서 고온기(8 월)에 생산된 대과종 파프리카의 품종별 과실품질 특성을 조사한 결과, 과고, 과폭, 과실당도, 과육두께에서 품종 간 유의성이 인정되었다. 당도는 주황색 품종인 ‘DSP-7054’와 ‘Naarangi’에서 높게 나타났고, 과육두께는 황색과 주황색 품종인 ‘K-Gloria orange’와 ‘Allrounder’에서 높게 나타났다. 근권 냉방처리 기간 동안 배지내 일평균 온도는 20.7℃로 나타났고, 근권 난방처리 기간 동안 배지내 일평균 온도는 23. 4℃로 나타났다. 근권부 냉난방 처리를 통해 상품수량은 무처리구에 비해 비해 ‘Nagano’ 16.5%, ‘Allrounder’ 1.3%, ‘Naarangi’ 20.2%, 및 ‘Raon red’ 17.3% 증가하였고, 품종 전체로는 16.1% 증가하였다. 근권 냉난방처리에 의해 과실의 경도는 4개 품종 평균 5.7% 증가하였으나 다른 품질 지표에서는 유의성있는 차이가 나타나지 않았다.
        4,300원
        4.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하절기 토마토 재배 시 주간 포그 냉방, 야간 히트펌프 냉방을 처리를 하여 냉방 처리가 온실 내 온습도, 작물의 생육 및 수확량에 미치는 영향을 분석하였다. 하절기 주간에 차광 처리한 대조구 온실의 평균 온습도는 32.1°C, 59.4%였고, 포그 처리한 시험구 온실의 평균 온도는 30.0°C, 74.3%로 나타났다. 이 때 외부의 평균 온습도는 31.4°C, 57.7%로 대조구 온실의 온도는 외기보다 0.7°C 높았으나 시험구 온실의 온도는 외기보다 1.4°C, 대조구보다 2.1°C 낮게 나타났다. 평균 습도는 시험구 온실 74.3%, 대조구 온실 59.4%로 포그 처리를 한 시험구에서 높게 나타났다. 야간 대조구 온실의 평균 온습도는 25.2°C, 85.1%였고, 히트펌프로 냉방을 한 시험구 온실의 평균 온습도는 23.4°C, 82.4%, 로 나타났다. 야간 외부의 평균 온습도는 24.4°C, 88.2%로 대조구 온실의 온도는 외기보다 0.8°C 높았으나 시험구 온실의 온도는 외기보다 1.0°C, 대조구보다 1.8°C 낮게 나타났다. 평균 습도는 시험구 온실 82.4%, 대조구 온실 85.1%로 나타나 시험구 온실의 습도가 더 낮게 나타났다. 작물 생육은 정식하고 8주 후에는 두 온실 간의 큰 차이는 없는 것으로 나타났으나 냉방 처리 후에는 시험구 온실의 작물이 대조구에 비해 경경, 초장, SPAD 값이 높게 나타났다. 토마토의 수확량은 냉방을 시작하고 2주 후까지 총 생산량의 차이는 1.2%로 큰 차이 없었으나 3주 후와 4주 후의 일 생산량이 시험구에서 대조구보다 많게 나타났다. 최종적으로는 시험구의 수확량이 81.3kg, 대조구의 수확량이 73.8kg으로 시험구가 대조구에 비해 10.2% 많게 나타남으로써 하절기 주간 포그 냉방, 야간 히트펌프 냉방이 작물 성장에 적합한 환경을 조성해 줌으로써 생육 및 생산성에 영향을 미친 것으로 판단된다. 냉방 처리에 따른 경제성을 비교해보면 대조구 온실에서는 142,166원의 수익이 있었던 반면 시험구 온실에서는 28,727원의 손해가 발생하여 냉방 처리는 경제성이 떨어지는 것으로 나타났다. 그러나 재식 밀도, 히트펌프 운용 시간 및 기간을 조절하여 에너지 사용은 줄이면서 생산성을 증가시킨다면 경제성도 확보할 수 있을 것으로 기대되며 이에 대한 추가 연구가 필요할 것으로 판단 된다.
        4,000원
        5.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 ‘설향’ 딸기의 관부를 부분 난방하고 양액을 온수로 공급하면서 관행 재배 방식에 비해 온실 공간 온도를 낮게 관리하는 딸기 부분 난방 시험을 수행하였다. 정식 후 11월까지는 특별한 처리가 없어 대조구, 시험구 모두 온실 내 환 경이 유사하게 관리되었으며 관부 난방 및 온수 양액을 공급 하기 시작한 12월부터는 야간의 온실 온도, 관부 온도 및 베드 온도가 차이를 보였다. 12월의 온실 야간 평균 온습도는 대조구 7.1℃, 87.2%, 시험구 5.7℃, 88.7%로 시험구의 온도가 낮았으나 관부 난방을 수행함으로써 시험구 온실의 관부 및 베드의 온도를 9.3℃, 12.7℃로 유지하였고, 대조구 온실의 관부 및 베드 온도 7.9℃, 10.8℃보다 높게 관리할 수 있었다. 시험기간 내에서 시험구 온실의 딸기 관부 및 베드 온도는 대조구에 비해 모두 약 2.0℃ 가량 높게 유지되는 것으로 나타났다. 주간에는 온수 양액을 공급함으로써 지하수를 이용했을 때보 다 평균 8.7℃ 높은 온도 양액을 공급할 수 있었고 이로 인해 베드 온도도 약 5.0℃ 가량 높게 나타났다. 시험구에서는 시험 기간 동안 온실 난방, 관부 난방 및 온수 양액 공급에 총 9,475.7×10 3 kcal의 에너지를 소비하였고 대조구에서는 온실 공간 난방에 총 16,847×10 3 kcal의 에너지를 소비하여 시험구에서 대조구 대비 약 43.8%의 에너지 절감 효과를 확인할 수 있었다. 시험구에서 딸기 관부의 온도를 높게 관리함으로써 작물의 생육을 촉진시킬 수 있었고 그로 인해 정식 후 초세가 대조구에 비해 좋지 않았던 시험구의 딸기가 25주 후에는 대조구와 생육적인 면에서 큰 차이가 없는 것으로 나타났다. 딸기의 수확량은 초세가 좋았던 대조구에서 1화방의 수확량이 시험구에 비해 많았으나 2화방, 3화방에서는 관부의 온도를 높게 관리한 시험구의 수확량이 더 많았다. 3월 말까지의 주당 수확량은 시험구 412.7g/plant, 대조구 393.3g/plant로 유의미한 차이는 없었으나 시험구가 대조구에 비해 4.9% 많이 나온 것으로 보아 딸기의 온도 민감부인 관부의 온도를 높게 관리하는 것이 딸기 생육과 생산성에 영향을 미치는 것으로 판단된다.
        4,000원
        6.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 PO필름과 PE필름을 온실의 피복재로 적용하였을 때 작물 수량 증대 및 에너지 절감에 미치는 영향을 조사하였다. 시험온실은 국립원예특작과학원 시설원예연구소 내에 위치한 단동온실(1-1W) 2동(B21, B23)과 2연동온실(1-2W 형) 2동(B15, B16)을 사용하였다. 단동온실의 규격은 폭 7.2m, 길이 30m, 측고 1.5m, 동고 3.6m 이고, 연동온실의 규격은 폭 8m, 길이 40m, 측고 3.1m, 동고 5.8m의 온실로서 이 중 골조로 된 아치형 표준온실이다. 동절기 시험을 위하여 PO 필름(외피 0.15mm, 내피 0.10mm)을 단동과 연동의 온실 피복재로 사용하였으며 대조구 온실로서 PE필름(외피 0.15mm, 내피 0.10mm)을 단동과 연동에 설치하였다. 시험작물은 완숙토마토 ‘해피니스’를 토양재배 하였고 2019년 12월 3일에 정식하여 2020년 4월 30일까지 재배하였다. 온실내부 야간 설정온도는 15℃를 유지하였으며 주간에는 23∽24℃를 유지할 수 있도록 측창 및 천창을 개방하였다. PO필름의 단동 및 연동온실 내부에서의 일사량, 온습도 등을 측정하였고, 재배 기간 동안의 생육량을 조사하였으며 에너지 절감 효과를 조사 하기 위해 피복재별 시험온실의 온풍난방기 연료 소비량을 조사하였다. 조사 결과 단동온실에서의 일사량은 PO필름 온실 에서 PE필름 온실보다 7% 증가하였고 수확량은 20% 증대되었다. 연동온실에서의 일사량은 PO필름 온실에서 PE필름 온 실보다 11% 증가되었고, 수확량은 9% 증가하였다. 또한 온실내부의 일평균 온습도 측정 결과 단동온실은 PE, PO필름 온실이 19.0℃, 19.1℃, 상대습도 75%를 나타냈고 연동온실 은 PO필름 온실이 19.6℃, 상대습도 57%를 나타냈고 PE필 름 온실이 18.8℃, 상대습도 63%를 나타냈다. 연료 소비량은 단동온실의 PO필름 온실이 PE필름 온실보다 12.4% 절감되 었고 연동온실에서는 PO필름 온실이 PE필름 온실보다 11.5% 절감된 것으로 나타났다.
        4,300원
        7.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to provide a basis for raising farm income by increasing the yield and extending the cultivation period by creating an environment where crops can be cultivated normally during high temperatures in summer. The maximum cooling load of the multi-span greenhouse with a floor area of 504 m2 was found to be 462,609 W, and keeping the greenhouse under 32°C without shading the greenhouse at a high temperature, it was necessary to fog spray 471.6 L of water per hour. The automatic fog cooling control device was developed to effectively control the fog device, the flow fan, and the light blocking device constituting the fog cooling system. The fog cooling system showed that the temperature of the greenhouse could be lowered by 6°C than the outside temperature. The relative humidity of the fog-cooled greenhouse was 40-80% during the day, about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The relative humidity of the fog cooling greenhouse during the day was 40-80%, which was about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The yield of cucumbers in the fog-cooled greenhouse was 1.8 times higher in the single-span greenhouse and two times higher in the multi-span greenhouse compared to the control greenhouse.
        4,300원
        8.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a controlled atmosphere (CA) storage system is proposed as a storage method for prolonging processing period. Persimmon was placed in CA storage at 0.5oC±0.5 for 92 d. The qualities of the stored persimmons were compared to determine the possibility of extending shelf life. ‘Sangjudungsi,’ which was harvested on October 26, 2017, was applied to the persimmons. In order to compare differences according to size, the persimmons were classified into Size No. 2 (170 g) and Size No. 3 (145 g). In the result, the yellowness of CA-stored persimmons was 26.3% lower than that of cold-stored ones, confirming that after-ripening was delayed. The firmness of CAstored and Size No. 3 persimmon was higher than that of cold-stored and Size No. 2 persimmon. Tannin decreased significantly in cold storage, but it tended to increase in CA storage. The sugar content of Size No. 3 was lower than that of Size No. 2, but there was no difference in tendencies according to the storage method. Weight loss in CA storage was lower than that in cold storage. A comparison of color difference, firmness, sugar content, tannin, and weight loss ratio showed that CA storage was more effective in improving shelf life than cold storage.
        4,000원
        9.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Commercial direct refrigerators have good energy efficiency, but are difficult to use for supercooled storage due to their large temperature deviation. Placing insulators and conductors inside the refrigerator could reduce these temperature deviations to within 0.3 degrees, allowing for the supercooled storage. The supercooled storage of salted Chinese cabbages during ten weeks was progressed to compare the other low temperature storages. The nucleation temperatures of salted Chinese cabbage were around -2.5oC and the freezing points were around -0.4oC, so -2oC was selected for the supercooled storage. The growth rate of lactic acid bacteria and yeast at -2oC storage was lower than that at 2oC storage. The reducing sugar was maintained higher due to the growth rate of lactic acid bacteria. The supercooled storage had an effect of delaying the fermentation of the salted Chinese cabbage, which may have the effect of delaying the fermentation of kimchi. This enhancement method of the direct refrigerator was effective for the supercooled storage and would be promising for commercial use.
        4,000원
        10.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관 (백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 20~23oC, 관부 온도를 13~15oC로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 20~23oC의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함 으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 4oC + 관부난방(처 리 1), 공간 난방 8oC (대조구), 공간 난방 6oC + 관부 난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 8oC(대조구)의 경우 1,320L (100%), 공간난방 4oC + 관부난방의 경우 928L(70.3%), 공간난방 6oC + 관부난방의 경우 1,161L (88%)로 계측 되었다. 공간난방 4oC + 관부난방(처리 1) 및 공간난방 6oC + 관부난방(처리 2)은 8oC 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.
        4,000원
        12.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        과거 한국에는 반달가슴곰이 많은 개체수가 서식하였다. 하지만 일제강점기와 한국전쟁을 거치면서 반달가슴 곰의 개체수가 급격하게 감소하였으며, 산업화, 서식지 파괴, 밀렵으로 인해 절멸 상태에 이르렀다. 2000년대 초반 지리산국립공원에서 극소수의 개체가 활동하는 것이 확인되었고, 이에 환경부에서는 절멸 위험에 처해 있는 생물종에 대한 복원과 생태계 건강성 회복을 위해 지리산 반달 가슴곰 복원프로젝트를 추진하였다. 외부로부터 한반도에 서식하는 반달가슴곰과 동일한 아종을 도입 방사한지 14 년이 흐른 2017년에 지리산에서 약 80 km 떨어진 수도산에서 반달가슴곰이 발견되었다. 유전자 분석결과 과거 지리산에서 방사했었던 3년생 반달가슴곰으로 분석되었으며 이는 지리산에서 반달가슴곰 복원사업을 추진한 이후 가장 멀리서 이동한 사례이다. 이후 지리산에서 2회 재방사를 하여 다시 수도산으로 이동하려는 움직임을 보였으며, 일반적으로 지리산에서 활동하는 반달가슴곰에 비해 많은 이동거리와 행동권을 나타냈다. 수도산에서 3번째 방사 이후 안정적인 이동 패턴과 서식영역을 띠고 있는 것으로 보이며, 이러한 사례 연구를 통해 지리산 반달가슴곰 집단의 서식지 확산과 이에 따른 광역적 관리 방안 마련에 필요한 자료를 제공하고자 하였다.
        4,000원
        14.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For the vessel export of strawberries, modified atmosphere package (MAP) using polyamide (PA) film and linear low density polyethylene (LLDPE) film was investigated to extend the shelf life of strawberries. Because the temperature and relative humidity changes of the MAP were lower than the changes of the control, the weight loss of the MAP were lower than that of the control. The low oxygen level and high carbon dioxide level were effective to decrease the fungal decay rate and to increase the hardness of strawberries. The Hunter’s color differences before and after storage showed no distinct difference between the MAP and the control. The lightness had a tendency to decrease while the redness increased. There were no significant changes of the soluble solids during the storage. The shelf life of strawberries could be extended to 16 days using the MAP considering the weight loss and the fungal decay rate. Thus, this MAP method using PA film and LLDPE film was effective to extend the shelf life of strawberries.
        4,000원
        15.
        2018.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main purposes of this study were to identify the factors affecting the supercooling property and to improve the possibility of supercooling storage of fruits and vegetables. Freezing point and nucleation temperature, moisture content, hardness, sugar content, and pH of nineteen fruits and vegetables were measured and Pearson correlation analysis was performed. Freezing point showed a statistically significant correlation with moisture content and sugar content (p<0.01), while ice nucleation temperature showed a correlation (p<0.05) only for sugar content. In particular, the water content and sugar content did not show any correlation with the freezing supercooling difference (FSD). From the correlation analysis between FSD, aerobic bacteria, lactic acid bacteria, yeast, and mold, FSD showed a correlation (p<0.01) with aerobic bacteria. The experiments of the saline solutions inoculated with aerobic bacteria at different concentrations showed FSDs of about 2 for saline inoculated with 9.4 log CFU/mL and about 6 for saline inoculated lower than 5 log CFU/mL. Therefore, the aerobic bacteria concentration was determined to be a key factor affecting the supercooling storage of fruits and vegetables.
        4,000원
        19.
        2018.10 구독 인증기관·개인회원 무료
        환경부 지정 멸종위기야생생물Ⅰ급 반달가슴곰(Ursus thibetanus ussuricus)은 20세기 초까지 한반도에 상당 수 분포하였으나, 산업화로 인한 서식지 소실과 밀렵, 포획 등으로 절멸위기에 처하였다. 반달가슴곰 복원사업은 개체군의 절멸을 방지하고 자체 생존력을 강화하기 위하여 2004 년부터 시작되었다. 개체 도입․방사와 출생 지리산 복원 개체군의 크기가 점진적으로 증가됨에 따라 일부 자연분산 현상이 관찰되고 있어, 지속적인 서식지역 확대와 사람과 곰의 조우에 대한 대비가 필요한 실정이다. 본 연구는 지리 산 일원의 반달가슴곰과 사람의 잠재적인 충돌 가능 지역 주변에서 활동 양상을 분석하여 이에 대한 관리방안을 제시하고자 하였다. 공간분석과 통계분석은 2015년부터 2017 년까지 지리산국립공원에서 일일 무선위치추적을 통해 수집된 반달가슴곰 20개체(female, n=9; male, n=11)의 위치 좌표를 이용하였다. 반달가슴곰 출현 지점으로부터 거주지역과의 거리, 농경지(과수원, 기타재배지, 논, 밭, 시설재배지, 하우스)로 부터의 거리, 정규 탐방로와의 거리, 사찰로부터의 거리 등 총 4가지로 구분하여 암-수성별, 계절별(봄, 여름, 가을) 출현 양상을 분석하였다. 잠재적인 충돌 위험 지역과의 거리를 분석한 결과, 거주지역과의 거리는 암컷이 수컷보다 더 가까운 경향을 보였고, 암-수 사이에는 유의적인 차이를 보이지 않았다(p>0.05). 농경지와의 거리, 정규 탐방로와의 거리, 사찰과의 거리 등은 암-수 사이에서 유의적 차이를 나타내었고(p<0.05), 농경지와의 거리, 정규탐방로와의 거리, 사찰과의 거리 모두 수컷이 암컷보다 더 가까 운 지점까지 접근하는 것으로 확인되었다. 계절별 양상을 분석한 결과, 거주지역과의 거리, 농경지와의 거리, 그리고 사찰과의 거리는 여름철에 가장 가까운 경향을 보였고, 정규 탐방로와의 거리는 가을철에 가장 가까운 것으로 나타났다(p<0.05). 본 연구 결과는 인간의 활동 영역에 접근하는 반달가슴곰의 성별, 계절별 행동 양상을 보여줌으로써 향후 지리산 지역에서 곰-사람 충돌을 감소시킬 수 있는 방안을 마련하는데 기초자료를 제공할 수 있을 것으로 판단된다.
        20.
        2018.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The O2 and CO2 concentrations in controlled atmosphere (CA) rooms are determined by the respiration of produce like apples and the airtightness of the CA room, with gas in the CA room controlled by O2 and CO2 removal as well as respiration (CO2 increase and O2 decrease). The purpose of this study was to evaluate the validity of the gas exchange model for O2 removal, CO2 removal, the rate of O2 decrease and CO2 increase by respiration of apples, and airtightness of the CA room. It took 17.5 hours to reduce O2 concentration from 20.9% to 2.0% after loading 4.3 tons of Fuji apples into the CA room, which was 4.2 hours longer than the 13.3 hours of the model formula. After the CO2 concentration rose to 0.5% due to respiration, it took 4.7 hours to lower the CO2 concentration to 0.2%, which was 0.6 hours longer than that of the model equation. The rate of CO2 increase by respiration was 0.021%/ h, which was similar to the model equation (0.017%/h). Also after 4.7 hours, the O2 concentration decreased by 0.1% which was also in line with the model equation (0.13%/h).
        4,000원
        1 2 3