검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2010.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The aim of this study is to estimate and compare indoor air quality(IAQ) at stock rooms in general library and in National Archives and to provide fundamental data in order to enact the law on management of IAQ at stock rooms in general library. The survey of IAQ in stock rooms was performed in Seoul National Archives in August 2009, and the basic data on level of indoor air pollutants in stock rooms at general library was collected from domestic journal. The concentration of NO2 was 114.1 ppb at audiovisual documentary stock rooms in National Archives. That value exceeded 50 ppb guideline that was legislated by the Korean Ministry of Public Administration and Security. The concentration of PM10 and VOCs were 59±9㎍/m3 and 367±83㎍/m3, respectively at stock rooms in general library. These values were exceeded from the guideline of Korean Ministry of Public Administration and Security that is 50㎍/m3 for PM10 and 400㎍/m3 for VOCs. Also, the exceeded probability from the guideline was 83.7% in PM10 and 35.6% in VOCs. Therefore, we suggest that a national plan for the management of IAQ at stock rooms in general library should be established.
        4,000원
        2.
        2008.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The airms of this study are to examine the concentrations of volatile organic compounds(VOCs) in hospitals and to compare concentrations of VOCsin hospital with public facilities. Mean concentraton of total volatile organic compounds(TVOCs) in hospital was 103.97±87.39㎍/m3, that was lower than guideline of KMOE. The highest concentration of VOCs in hospital was 19.07±13.47㎍/m3 for Toluene. The distribution of VOCs in hospitals was log-normal distribution. As the result of Monte carlo simulation, the distribution of VOCs in hospitals was log-normal distribution with the exception of Toluene with normal distribution.
        5,100원
        3.
        2008.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        After infection by Gram negative bacteria, neonatal patients or patients in intensive care unit usually suffer from endotoxin shock, leading to death finally in spite of eradication of bacteria by potent antibiotics. The purpose of this study that is the pilot study to prevent endotoxin shock and nosocomial infection, is to offer basic data on species and concentrations of airborne microbes in hospitals. Therefore, this study collected and analyzed articles and documents on airborne microbes in hospitals in Korea that were published in relevant journals from 1980 to 2004. Studies on the concentration of airborne microbes in hospitals as a part of study on the nosocomial infection have been performed from the latter half of 1970s. Pooled average concentrations of total suspended bacteria in hospitals by RCS air sampler and Cascade air sampler were 194.85 CFU/㎥ and 367.72 CFU/㎥, respectively. They were lower than the guideline concentration(800 CFU/ ㎥) of the Korean Ministry of Environment. Pooled average concentrations of total suspended fungi in hospitals by RCS air sampler and Cascade air sampler were 20.66 CFU/㎥ and 193.34 CFU/㎥, respectively. They were lower than the guideline concentration(150 CFU/㎥) of the World Health Organization(WHO). Pooled average concentrations of total suspended bacteria in operating room and intensive care unit(ICU) were 324.75 CFU/㎥ and 182.43 CFU/㎥, respectively. They again were lower than the guideline concentration of the Korean Ministry of Environment. Staphylococcus spp., Micrococcus spp., and Lactobacillus spp. for Gram-positive bacteria, and Pseudomonas spp., Klebsiella spp., and Escherichia spp., for Gram-negative bacteria were shown in hospitals. Also, Aspergillus spp., Penicillium spp., Mucor spp., Epidemophyton spp., Trichophyton spp., and Cladosporium spp. for fungi were found in hospitals. Staphylococcus spp. was shown frequently in operating rooms, intensive care units and wards. Penicillium spp. and Aspergillus spp. were shown commonly in them.
        5,400원