검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is on the performance characteristics of bubble pump with vertical pipe of different lengths. For the experimental facilities composed of electrical heater used for providing heat source to generate bubble, a vertical tube with Ø4mm diameter, length of 200mm, 300mm, 400mm and 500mm. Storage tank with capacity was of 40 L containing a heat exchanger. The separator and condenser of the air bubble pump were installed separately. The results obtained from this experiment are as follows: there were a few variations of values of temperatures according to vertical pipe lengths of the bubble pump. The mass flow rate was increased by 0.17g/s when it was short as 200㎜ long pipe. But when vertical pipe length was 500㎜, it reached the normal temperature quickly because the slug flow occurred in this case at initial stage. Consequently, it was found that 500㎜ of the vertical pipe length was optimum for best performance of bubble pump.
        4,000원
        2.
        2019.08 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 여러 가지 하지입식검사에 적용할 수 있는 Multi-Function Device(MFD)를 제작하여 기 존에 사용하던 Weight Bearing Platforms(WBPs)들과 X 선 영상의 비교를 통해 임상 활용을 제안하고자 한 다. MFD는 단상(보조기구)를 이용한 Weight Bearing Foot/Ankle, Hindfoot Alignment View 검사시 X선 장치 의 X선 관구의 최하 조절 높이를 고려하여 제작하였다. 그리고 Foot/Ankle Phantom으로 MFD와 WBPs에서 Weight Bearing Lateral Foot과 Hindfoot Alignment View를 검사하여 X선 영상의 해상력을 Quick MTF(modula tion transfer function)프로그램으로 비교하였다. 연구결과 MFD와 WBPs에서 검사한 두 가지 영상 모두 MTF 50(50% Contrast Spatial Frequency)과 10-90%(10-90% of Maximum Energy Rise Distance) Rise의 C/P(Cycles Pe r Pixel)평균과 LPH(Lines Per Image Height)평균 모두 유의한 차이는 없었다(p>0.05). 연구에서 제작한 MFD 는 환자의 안전과 여러 가지 검사를 복합적으로 수행 할 수 있는 유용한 보조기구로 임상 활용을 제안한 다. 또한 정책적으로 보조기구의 활용을 권장한다면 전문 업체의 활성화를 돕는 길이며 의료의 질도 더욱 향상할 수 있을 것이다.
        3.
        2017.09 KCI 등재 서비스 종료(열람 제한)
        This paper is containing two study. The one is a land treatment of sewage sludge reduction through the indirect heating method and the other verifies conversion possibility of sludge organic matter to auxiliary fuel, steel thermal insulation material, byproduct fertilizer compost and find the suitable recycling method for J city. It was confirmed that about 88 percent of weight reduction for transportation efficiency and method verification. The analysis result of the carbonized product component showed the average low heating value of about 2,850 kcal and the moisture content of 1.4% which means the sludge is suitable as a fuel.
        4.
        2011.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 LVEF값이 40% 미만인 환자와 정상인 환자의 심장 박동 수를 비교 분석하여 CCTA 검사 프로토콜의 최 적화를 통한 양질의 영상, 환자피폭과 재 검률을 최소화시키기 위함이다. 각 심장박동수와 LVEF에 관계에서 LVEF가 40%이하가 될 때 true 100HU에 도달하는 시간이 오래 걸림을 알 수 있다. 그러므로, 40% 미만인 환자들에서 Premonitoring deay를 설정 할 때 5초정도 더 주어도 됨을 알 수 있었다. 조 영제는 Scan time x 4cc + 30cc의 용량을 4cc/sec속도로 주입한 후 이어서 Saline은 모든 환자에게 40cc를 4cc/sec속 도로 추가 주입하였으며, 40% 미만에서는 HR이 80이상을 제외하고는 큰 차이를 보이는 것 을 알 수 있다. 또한, 40% 미만에서는 조영제가 true 100HU에 도달하여 Scan을 시작 할 때 시간 차이가 커 조영제가 이미 Left ventricle에서 Wash-out 됐음을 예측 할 수 있었다. 40%이상의 LVEF와 정상 이하의 LVEF는 검사 도중 많은 차이를 가지고 있다. 낮은 LVEF 환자에게서 검사를 시작 할 경우. 따라서, 조영제 주입 프로토콜은 LVEF에 따라서 CCTA에 결정되어져야 한다. 그리고 우리가 낮은 LVEF에 따라 검사 실패를 감소시켜야 하기 때문에 낮은 LVEF의 경우에는 일반적 Pitch 보다 낮은 Pitch가 사용되어져야 한다.