Background: Cervical dysfunction is a common pathomechanical marker in individuals with forward head posture (FHP). To overcome the limitations of the isometric chin-tuck (ICT) exercise, dynamic neuromuscular stabilization (DNS), which emphasizes an entire spinal chain exercise, has recently shown promising clinical results.
Objects: Purpose of this study was to compare the immediate effects between ICT and DNS techniques.
Methods: 43 young subjects (mean age, 24.0±5.0 years) were recruited. Group of subjects with FHP were measured under baseline, ICT, and DNS conditions. Outcome measures included sitting height, longus colli (LC) and sternocleidomastoid (SCM) muscle thickness and LC/SCM thickness ratio. One-way repeated measures ANOVA was used to compare the continuous dependent variables among FHP, ICT, and DNS conditions at p<.016.
Results: Both ICT and DNS exercise conditions yielded significantly increased LC muscle thickness,
LC/SCM thickness ratio and sitting height than did FHP condition (p<.0001, respectively). Sitting height was significantly greater in DNS exercise than in the ICT exercise (p<.0001).
Conclusion: The present results demonstrated that sitting height was greater in the DNS exercise than in the ICT exercise, as well as both corrective postural training exercises were effective on LC/SCM muscle balance ratio when compared with the baseline FHP condition. Therefore, it is considered that DNS exercise can be the recommended exercise for people with FHP.
Background: Knee osteoarthritis (OA) is a single most arthritic disease. Knee joint space width (JSW) is commonly used for grading severity of knee OA. However, previous studies did not established criterion validity and test-retest reliability of ultrasound (US) image for measuring JSW.
Objects: The aim of this study was to establish criterion validity and test-retest reliability of US measurement of medial and lateral knee JSW.
Methods: Twenty-nine subjects with knee OA were participated. The US and X-ray were used to measure knee JSW. One sample Kolmogorov-Smirnov test was used to confirm the data normal distribution. Pearson correlation coefficient and ICC were used to calculated and establish criterion validity and test-retest reliability, respectively.
Results: US measurement of medial and lateral knee JSW was highly correlated with radiographic imaging measure (r=.714 and .704, respectively). Test-retest reliabilities of medial and lateral knee JSW were excellent correlated (ICC=.959 for medial side and .988 for lateral side, respectively).
Conclusion: US may be valid tool to measure knee JSW.