        81.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This experiment evaluated the efficiency of mechanical ventilation, one of the measures to reduce indoor radon concentration in residential spaces. In the most popular ventilation rates of the air conditioning system, the most efficient air conditioning system was confirmed by checking the time when the radon concentration reached the lowest level, the radon reduction rate, and the radon concentration that could be lowered as much as possible. The results showed a reduction rate of up to 80% or more as a result of conducting the experiment by blocking the inflow of outside air. It was confirmed that the time to reach the lowest concentration after starting the mechanical ventilation was about 6 hours to a maximum of 7 hours. Therefore, this study verified that indoor radon concentrations can be efficiently reduced by using a mechanical ventilation system.
        4,000원
        82.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effect of improving indoor air quality according to the installation of plants was evaluated in classrooms where students spend much time. The purpose was to prepare sustainable and eco-friendly measures to improve the indoor air quality of school classrooms. A middle school in Bucheon was selected as an experiment subject, and IAQ monitoring equipment based on IoT was installed to monitor indoor air quality. After measuring the basic background concentration, plants and air purifiers were installed and the effects of improving indoor air quality using plants and air purifiers were evaluated based on the collected big data. As a result of evaluating the effects of indoor air quality improvement on the installation of plants and air purifiers, the reduction rates of PM10 and PM2.5 in descending order were plant- and air purifier- installed classes, air purifier-installed classes, and plant-installed classes. CO2 levels were reduced in the classrooms with only plants, and increased in two classrooms with air purifiers. The increase in CO2 concentration in the classrooms with plants and air purifiers was lower than in those with only air purifiers.
        4,600원
        83.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.
        4,000원
        87.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High concentrations of PM2.5 were generated in new apartments before moving in, and PM2.5 reduction efficiencies using air cleaners and ventilation systems were evaluated. The experimental results for different air cleaner capacities showed that the PM2.5 reduction efficiencies for 46.2 m2, 66 m2, and 105.6 m2 areas were 81.7%, 92.9%, and 92.5%, respectively. Thus, the larger the air cleaning application area, the higher the PM2.5 reduction efficiency. However, there was no difference in the efficiency of overcapacity air cleaners above a certain capacity. The efficiencies of air cleaners located at the living room center, interior wall, and edge were 81.7%, 79.2%, and 75.8%, respectively. There was, therefore, no significant difference in the PM2.5 reduction efficiencies of air cleaners in different locations. Furthermore, the PM2.5 reduction efficiencies at distances of 1 m, 2 m, and 3 m were 81.7%, 81.3%, and 81.7%, respectively. Therefore, there was also no significant difference in efficiency with distance. The PM2.5 concentration decreases rapidly during natural ventilation. Therefore, when the indoor PM2.5 is higher than the outdoor PM2.5, the air cleaner should be used after natural ventilation. The efficiency of PM2.5 reduction using an air supply-type ventilation system in apartments was 35%, which is not high. The simultaneous operation of the ventilation system and kitchen range hood was effective, showing a PM2.5 reduction efficiency of 69.1%. However, a water sprayer was not effective, showing a PM2.5 reduction efficiency of 24.3%. The results of this study suggest that PM2.5 reduction performance should be standardized by evaluating the efficiency of different ventilation systems. Effective usage and maintenance standards for ventilation systems need to be disseminated, and ventilation systems and air cleaners should be used effectively.
        4,000원
        88.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 기존의 신호체계에서 발생하는 황색 신호 딜레마 상황에서 운전자의 상태를 파악하고 새로운 신호체계를 제안하고자 한다. 특히, 생체신호 분석을 통해 운전자 중심의 대처모형을 제안한다. 이를 위해 자동차 그래픽 시뮬레이터를 통해 교차로 도로 주행상황을 구현하여 기존의 신호체계와 본 연구에서 제안하는 신호체계에서 운전자의 생리적 반응을 관찰하여 규명하고자 한다. 따라서 대조군(기존 신호체계)과 새로운 황색 신호체계를 실험군(새로운 신호체계)으로 나누어 20대 초보 운전자를 중심으로 실험을 진행하였다. 그 결과, 대조군보다 실험군에서 교감신경의 출현이 우세하였으며 통계적으로 유의차가 인정되었다(p<0.05). 이를 통해 새로운 신호체계가 운전자가 긴장감을 유발하는 것처럼 보이지만 교감신경과 부교감신경의 비율이 6:4로 이상적인 균형으로 해석할 수 있다. 결론적으로, 본 연구에서 제안하는 대처 신호체계를 교통체계에 적용한다면 운전자가 더욱 안정적인 주행이 가능할 것으로 보인다.
        4,000원
        90.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a motion control problem for the vessel towed by towing ship on the sea is considered. The towed vessel does not have self-control capabilities such that its course stability totally depends on the towing ship. Especially, in the narrow canal, river and congested harbor area, extreme tension is required during the towing operation. The authors, therefore, propose a new control system design method in which the rudder is activated to provide its maneuverability. Based on the leader following system configuration, a nonlinear mathematical model is derived and a backstepping control is designed. By experiment results with nonlinear control framework, the usefulness and effectiveness of the proposed strategy are presented.
        4,000원
        94.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Over the years, the concentration of fine dust is gradually increasing, thereby aggravating the seriousness of the situation. Accordingly, this study intends to install a clean road system using low impact development (LID) techniques on the roadside in order to reduce the scattering of dust on roads effectively. This system stores rainwater collected through gutters in rainy weather and sprays water onto the pavement surface to reduce the scattering of road dust. METHODS : The developed clean road system consists of a water tank, controller, rain detection sensor, and solar cell. Based on this, a test-bed construction was used to evaluate its applicability. By applying the developed system, actual applicability was evaluated through total suspended solid (TSS) test and fine dust measurement. TSS test was conducted to measure the reduction rate of scattering dust on the road owing to the water injected by the clean road system. A spray nozzle was used for the TSS test, and a nebulization nozzle was used for the measurement of fine dust. In order to increase the reliability of the test, three measurements were taken each, for normal road as well as unfavorable conditions road that reproduced the construction site. RESULTS : In this study, fine dust concentration measurement and TSS test were conducted to evaluate the practical applicability of the developed clean road system. From the TSS test, it was found that for both general roads and roads depicting bad conditions, the TSS value after the first spray was the highest, and the value after the second spray was sharply reduced, such that most of the re-dispersed dust was washed out after the first spray, and similar TSS value results were obtained after the third spray. Based on this result, the result of fine dust measurement showed similar fine dust reduction effect of 9%-15.9% regardless of the concentration of fine dust in the atmosphere. These results indicate that the concentration of fine dust in the atmosphere does not significantly affect of the degree of reduction in fine dust. CONCLUSIONS : In this study, a clean road system for reducing fine dust on the road was developed and its applicability was evaluated. In a future study, we intend to check the performance of the drainage pavement through performance evaluation of water permeability coefficient test and performance test in the form of drainage pavement. Through this, we intend to evaluate the applicability of the clean road system to which drainage pavement is applied. Moreover, we will develop a clean road system that applies drainage packaging, and analyzes the degree of fine dust reduction according to the spray angle, spray amount, and spray time of the clean road system in order to study the spray system with the optimum amount of fine dust reduction. In addition, in order to reduce fine dust in the winter, when fine dust is mainly generated, it is planned to install heating wires in spray pipes where freezing is expected. Lastly, the black ice prevention effect will be analyzed by mixing a certain amount of sodium chloride when spraying water.
        4,000원
        96.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 주류공장 내 고농도 CO2 제거 및 포집을 위해 L-alanine 흡수제를 적용하여 CO2 흡수, 탈리 효율을 평가 후 재생 성능을 확인하였다. 탈리공정의 효율적인 처리를 평가하기 위해 실험 실 규모에서 Hot plate, Steam 두가지 탈리 방법을 비교하였으며 Hot plate는 약 10%, Steam의 경우 약 60%의 재생효율을 확인하였다. 따라서 주류공장 내 100m3/min 실증화 규모에 Steam-Tower 탈리공정을 적용하여 최적조건을 평가한 결과 탈리 유량 4L/min 이하, Steam 온도 160℃ 이상, 탈리효율 85.5%로 확 인할 수 있었다.
        4,000원
        97.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 우리나라는 대규모 지진이 빈번히 발생하고 있으며, 유감지진의 발생 규모 및 빈도가 급격히 증가하고 있어 지 진피해 저감 기술에 대한 관심이 증대되고 있다. 기존 지진피해 저감 기술은 구조물의 단면적을 크게하여 강성을 증가시키는 방법으로 과도한 설계 및 시공이 발생하여 상당한 비용이 소요되고 경제적인 측면에서 비효율적이다. 구조물에 대해 지진하중 으로부터 효율적으로 대응하기 위한 내진설계 방법에는 제진기술이 있다. 제진기술에 활용되는 제진장치는 지진 발생 후 재료의 항복으로 인해 장치의 손상 및 파괴가 발생하여 교체가 불가피하고 시간 및 비용이 소요된다. 따라서 이 연구에서는 기존 제진기술의 단점을 보완하기 위하여 에너지 소산 능력 및 복원력이 우수한 초탄성 형상기억합금 및 폴리우레탄 적용 자동복원 감쇠장치의 구조실험을 수행 및 분석하여 지진 발생 후 지속적으로 활용 가능한 댐퍼 장치에 대한 연구를 수행하였다.
        4,000원
        98.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Generally, vibration absorber systems are composed of spring-mass systems to reduce the vibration of a structure, and there are also methods to simply increase damping to achieve a damping effect across a wide frequency band. One similar method is to use a mechanism in which the eddy current is converted into a mechanical damping effect. When an eddy current is generated by electromotive force due to magnetic flux change, the reaction force is generated by the eddy current’s circulation. In this study, the damping system using the reaction force was constructed to reduce the transmission of vibrations generating from internal fluid and the vibration reduction characteristics that are transmitted externally were analyzed. As a result, 8.2 % of the vibration reduction effect from primary excitation frequency was confirmed.
        4,000원
        99.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 합성가스의 에너지화를 위한 가스엔진 성능 평가를 수행하였다. 회전수 1800 rpm 조건에서 공기과잉률이 1, 1.1, 1.2, 1.3, 1.4, 1.5, 1.6 증가에 따른 엔진출력(kWm)과 열효율(%)을 평가한 결과, 공기과잉률 λ 1.4에서 엔진출력 34 kWm를 나타냈으며, 공기과잉률이 증가할수록 엔진 열효율은 전반적으로 감소하는 경향을 보였다. 엔진출력 34 kWm 조건에서 공기과잉률이 1, 1.1, 1.2, 1.3, 1.4 증가시 열효율이 34.2%, 36.9%, 37.2%, 37.4%, 38.1%로 증가하였고, 발전출력을 통한 종합효율은 발전출 력 30 kWe 부하조건에서 38.7 kg/h의 연료를 소모하여 32.1%의 발전효율과 냉각수와 배기가스에서의 열 회수를 통해 57.3 kW의 폐열을 회수하여 53.8%의 열을 회수하여 총 85.8%의 종합효율을 보이는 것으로 나타났다.
        4,000원
        100.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study developed an evaluation system of adaptation countermeasures for climate change in the water resources sector using the Analytic Hierarchy Process (AHP), and the assessment procedures were applied to the Second Chungcheongnam-do Climate Change Adaptation Implementation Plan (Chungnam Implementation Plan). Firstly, the evaluation criteria are composed of two levels according to the hierarchical structure, and AHP gives priority to 4 evaluation criteria of the first level and 16 alternative indicators of the second level. Secondly, after the importance of the evaluation criteria or indicators has been determined, the significance of each measure was evaluated by applying it to the water-sector measures of the Chungnam Implementation Plan, and the effectiveness of the evaluation system was validated. The Chungnam case study shows that the evaluation system will be more effective and efficient when it is applied during development phase rather than after the implementation plan is finalized. It is also expected that the evaluation system will be used to evaluate and prioritize climate change adaptation policies in other regions, and then to compare the means of adaptation to climate change in various regions and to select recommendation policies.