검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 108

        3.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study focuses on the application of a new measurement method that quantifies the residual color of filtered water using a spectrocolorimeter after filtering the discolored substances. It was confirmed through the color and turbidity cross-test that the discolored substances cannot be measured effectively with the current legal color and turbidity test method. Therefore, the National Institute of Environmental Research's filter testing method, which involves filtering the sample through 0.45 μm filter and visually inspecting the color, was improved. A membrane filter colorimetry (MFC) method was established by measuring the color difference (ΔE*ab(65)) of the filtered filter using a spectrophotometer and expressing it as filter color unit (FCU). Using the MFC method, the FCU for reference materials such as iron and manganese, as well as field samples, was measured. The results showed a high correlation with turbidity, and the color difference patterns varied depending on the type of reference materials and field samples. This indicates that the MFC method is an effective new measurement method of discolored tap water.
        4,900원
        5.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, the alkali aggregate reactivity and expansion characteristics of mortar mixed with waste glass (a recycled aggregate) were confirmed to verify the alkali-silica reaction (ASR) stability and review the appropriateness of the alkali aggregate reactivity test method following the replacement of recycled aggregate. METHODS : The alkali-aggregate reactivity of waste glass aggregates was measured using the chemical and physical methods described in KS F 2545 and ASTM C 1260, respectively. The reactivity was classified by comparing the results. Cement with a high-alkali content was used to simulate an environment that can induce ASR. Non-reactive fine aggregates, waste glass fine aggregates, reactive general aggregates, and Ferronickel slag aggregates were used as control groups. RESULTS : Waste glass fine aggregates were classified as reactive when applying the chemical method. In the physical method, they were classified as reactive at 100% and latent reactive at 1%, based on the mixing ratio. Additionally, we discovered that the reliability of the chemical method was low since the ASR of the aggregates was classified differently based on the evaluation method, while the results of the chemical and physical test methods were inconsistent. CONCLUSIONS : To determine the alkali reactivity of recycled aggregates, the complex use of chemical and physical methods and analysis based on the mixing ratio of the reactive aggregates are required. Small amounts of waste glass aggregate replacements affected the ASR. Because ASR reaction products can affect the long-term thermal expansion of the structure, further research is needed to use ASR aggregates in structures.
        4,000원
        6.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The aim of this study is to review freeze-and-thaw testing apparatuses, develop a freeze-and-thaw testing setup with a test protocol, test the freeze-and-thaw properties of soils collected from different parts of South Korea, and suggest an index for frost susceptibility criteria for soils found in South Korea. METHODS : Based on a literature review, a new freeze-thaw testing setup was developed. In addition, a test protocol was developed for freeze-thaw testing. Soils collected from different parts of South Korea and bedding sand used for block pavements were tested to determine whether the measurements from the newly developed test setup could capture important freeze-thaw characteristics of the soils. Finally, to develop local frost susceptibility criteria, a parameter including both the vertical deformation and thermal conductivity characteristics of the soils was suggested. RESULTS : The results from the laboratory experiments indicate that the newly developed freeze-and-thaw setup captures the required parameters to quantify the responses of soils subjected to cyclic freeze-and-thaw testing. In addition, a vertical deformation of up to 2.437 mm is measured. Moreover, seven soils out of the nine tested soils are classified as having a medium frost susceptibility, whereas the remaining two show low frost susceptibility. The bedding sand experiment also shows that there is a possibility of having a frost susceptible condition based on the moisture content. When submerged, the bedding sand is classified as having a medium frost susceptibility. CONCLUSIONS : The "HEART" freeze-thaw testing setup was able to capture the parameters required for evaluating the frost susceptibility of soils. This setup and testing procedure could be further used to test and prepare criteria for classifying the frost susceptibility of soils found in South Korea.
        4,000원
        7.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Failure to comply with the performance test requirements for the centrifugal pumps at power plants often results in performance dissatisfaction as a result of field tests. This study proposed a method of reducing the uncertainty of the field test results by evaluating the systematic error in the measurement system caused by failure to follow the test requirements using the computational fluid dynamics(CFD) technique. As a result of the evaluation of the systematic error and reflecting it in the performance test data, it was confirmed that the error occurred at a constant rate with respect to the flowrate and that the pump, which showed a difference in performance actually had the same performance.
        4,000원
        10.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        ROPS is a structure installed to protect drivers from tractor rollover accidents and is being tested for certification under the OECD code. Because this test requires a lot of cost and time to develop the ROPS and to produce test model, the OECD is discussing the introduction of virtual test using finite element analysis. In this study, the results were compared by conducting a strength test and finite element analysis applied with the OECD code to use it as a basic data for standardization of ROPS virtual test methods. It was confirmed that the results of the analysis of the bolts and plates of the coupling part and the folding part were more close to the physical test results than the rigid elements and constraints at the point of coupling the tractor and ROPS.
        4,300원
        11.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In general, a high-performance concrete construction method is a method of loading mixed cement and other materials on a mobile mixer equipped with a concrete plant. However, the construction cost is high because the unit cost of the mixed cement is very high and the equipment usage fee of the mobile mixer is also high. To compensate for these drawbacks, a cellular spray concrete method was developed. This is a highly functional customized concrete construction method in which admixtures are added to high-flow concrete with cellular (air bubbles) added at the site and constructed through spraying. METHODS : Field workability evaluation using cellular concrete was carried out using a spray method in 2017 and an anti-foaming agent in 2018. The test construction section was set as a new road-pavement construction site. After construction, strength, durability characteristics, and void analysis were performed to compare the construction methods. The results of laboratory tests under optimal conditions were also compared to the on-field results. By comparing the indoor mixing and the on-field results, we analyzed whether there were any problems concerning the performance expression. The economic feasibility at the initial construction stage was analyzed by comparing the existing and the cellular concrete construction methods in terms of material cost and equipment usage fee. RESULTS : In the case of cellular spray concrete, construction through spraying is cumbersome, and the need to additionally use large equipment such as a pump car and compressor constitutes a disadvantage. However, the most relevant feature is that it can be constructed not only on the floor, but also on a slope. In the case of cellular concrete with an antifoaming agent, it was possible to quickly produce high-performance concrete using on-site remixing equipment. By supplying materials to the pouring surface using a conveyor, smooth construction and construction in narrow spaces were also possible. CONCLUSIONS : The cellular concrete method allows the immediate on-site production of high-performance concrete, and it is possible to selectively apply spray construction, antifoaming agent construction, etc.
        4,000원
        12.
        2021.05 구독 인증기관 무료, 개인회원 유료
        In defense acquisition system, testing and evaluation is a very important procedure that can ensure the completeness of capability while deciding whether to mass-produce or purchase weapons systems. But it always includes realistic restrictions that involve a variety of stakeholders, but lack of time, resources, and budget. Therefore, in the process of planning a test and evaluation, proper number of prototypes and reliability of test results, along with test items and evaluation criteria, are frequently discussed as sensitive agendas. In reality, however, rather than statistical judgments, the number of prototypes and tests are determined by business logic such as duration and budget. Otherwise, most theoretical studies do not adequately reflect the business logic of test assessment. In this study, we propose a number of prototype and tests method that can statistically reasonably verify the performance of the inorganic system considering the characteristics of each test and evaluation project. To this end, we consider the theory related to determining the number of prototypes and tests, and present examples by separating whether to secure the magnitude of effects that have a significant impact on statistical judgment. This study could contribute to the development of empirical methodologies that can adequately coordinate reality and theory in the field of defense test evaluation while ensuring statistical reliability of test evaluation results.
        4,000원
        13.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to provision the standard method for ensuring the reliability of measuring indoor air quality in public transportation. The objective is to determine the difference in the measured concentration values according to various conditions. These variables include measurement conditions, measurement equipment, measurement points, and measurement time. The value differences are determined by measuring the PM10 and CO2 concentration of subways, and express buses and trains, which are targets of indoor air quality management. The concentration of CO2 was measured by the NDIR method and that of PM10 was measured by the gravimetric method and light-scattering method. Statistically, the results of the concentration comparison according to the measurement points of the public transportation modes were not significantly different (p > 0.05), and it is deemed that the concentration is not affected by the measurement points. In terms of the concentration analysis results according to the measurement method, there was a difference of the concentration between the gravimetric and light scattering method. In the case of the light scattering method, the concentration differed depending on whether it was corrected with standard particles in the laboratory environment.
        4,200원
        14.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 압입시험을 통해서 초탄성 재료 물성치를 평가하는 간단한 방법을 제시하였다. 초탄성 재료 모델 중, 3개의 물성치(C10, C20, C30)를 가지는 Yeoh 모델을 선택하여 주연신률로 표현되는 변형률 에너지 밀도를 적용하였다. Yeoh 물성치를 변화시키며, 구형 압입시험 유한요소해석을 수행하여 압입자 반력-변위 곡선을 획득하였다. 압입자 반력-변위 곡선을 3차 다항식으로 근사하였고, 이 다항식을 물성치(C10, C20, C30)의 3차 곱으로 근사된 3차 다항식으로 표현하였다. 압입자 반력-변위 곡선 근사를 위해 회귀분석을 진행하여 수식들의 계수를 결정하였으며, 이 회귀식을 이용하여 초탄성 재료의 물성치를 평가 하였다. 초탄성 재료 물성치 평가를 수행하고 오차를 비교하여 유효성을 보여 주었다.
        4,000원
        15.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Given the view of tests as mechanisms within a language policy framework (Shohamy, 2006), Korean proficiency tests are not only used as a way to measure language knowledge, but rather as tools to impose national ideologies about langage use and diversity. The field of Korean language testing needs to embrace sociopolitical dimensions, and engage what is going on value and consequence in test development and validation. By drawing upon a combined approach of Messick’s (1989) validity framework, Fairclough’s (2001) Critical Discourse Analysis (CDA), Bachman and Palmer’s Assessment Use Arugment (AUA), this study aims to illustrate how the practice of testing can be discursively interpreted as a multilayered phenomenon, constituted through discourse. It discussed the applicability of AUA’s two claims (decisions, consequences) to the validation of Korean language proficiency or related certification testing for immigrants with foci of value implications and consequences. The interconnectedness of test validation and CDA is modelled through the procedure of Faircough’s (2001) analytic methodology. In an effort to illustrate that language testing is discursively value-laded, this study not only offer a theoretical and methodological addition to the current inquiry of test validation, but also re-emphasize that language testing is sociopolitically driven from a discursive angle.
        6,600원
        18.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examines the domestic and international bulletproof test standards of armor and plate which are supplied to the domestic market. In addition, improvements and suggestions for the test standard were presented. Experiments were conducted to clarify the distances to the edge, the difference between ammunition makers, and the position of the impact point of the bulletproof plate, which have been discussed in the conventional bulletproof test. As a result of the study, it was confirmed that the bulletproof performance is excellent as the distance from the edge increases. Next, performance differences between ammunition makers were not found. Finally, plates should be applied to the US ESAPI test specification to provide a clear and reproducible test method.
        4,000원
        20.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is a summary of the complex odor proficiency testing method using the air dilution sensory method conducted for the last 7 years. Results of the homogeneity and stability test were obtained from the measurement of the standard sample for identifying the range of measurable concentration so that the complex odor proficiency testing method was established through processing the manufactured standard sample and distribution method. Standard samples were prepared using a large Teflon bag after being homogeneously mixed inside a Teflon bag. Also, a distributing container was selected with a polyester aluminum bag in order to avoid samples of the best condition from being contaminated during transport as well as being exposed to invasive odor from a sampling bag. Test results revealed that the mixture of toluene and m-Xylene was most appropriate for this proficiency testing method to the homogeneity and stability of the testing method. In addition, DMS and DMDS were the optimized samples at the outlet area. As a result, the standard method was established to address the analysis quality management to the mixed odor inspection agencies in Korea.
        4,000원
        1 2 3 4 5