검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 17

        3.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, an unprecedented emerging infectious disease has rapidly spread, causing a global shortage of wards. Although various temporary beds have appeared, the supply of wards specializing in infectious diseases is required. Negative pressure isolation wards should maintain their function even after an earthquake. However, the current seismic design standards do not guarantee the negative pressure isolation wards’ operational (OP) performance level. For this reason, some are not included in the design target even though they are non-structural elements that require seismic design. Also, the details of non-structural elements are usually determined during the construction phase. It is often necessary to complete the stability review and reinforcement design for non-structural elements within a short period. Against this background, enhanced performance objectives were set to guarantee the OP non-structural performance level, and a computerized tool was developed to quickly perform the seismic design of non-structural elements in the negative pressure isolation wards. This study created a spreadsheet-based computer tool that reflects the components, installation spacing, and design procedures of non-structural elements. Seismic performance review and design of the example non-structural elements were conducted using the computerized tool. The strength of some components was not sufficient, and it was reinforced. As a result, the time and effort required for strength evaluation, displacement evaluation, and reinforcement design were reduced through computerized tools.
        4,000원
        5.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 Comfortone 기법 적용 전, 후 음압 수준(sound pressure level, SPL) 변화 정도와 영상의 화질 차이를 정량적으로 비교, 분석하여 소음 감소 기술의 유용성과 임상적으로 유의미한 기준을 제시하고자 하였다. 3.0 T 자기공명영상장비와 ACR 팬텀을 사용하여 Comfortone 적용 전, 후의 T1, T2 강조 영상과 DWI, FLAIR, 3D GE T1 영상을 획득한 후 ACR 정도 관리 가이드라인에 따라 기하학적 정확도, 고대조도 공간분해능, 절편 두께 정확도, 절편 위치 정확도, 영상 강도 균일성, 고스트 신호 백분율, 저대조도 분해능이 적합한지 비교, 평가하였으며 장비 내 표시되는 SPL을 통해 음압 수준의 감소 차이를 비교하였다. Comfortone 기법 적용 여부에 관계없이 DWI 영상은 왜곡이 심해 장비 정도 관리 가이드 라인에는 적합하지 않았으나 나머지 영상에서는 대부분 통계적으로 유의한 차이가 없었다(p>0.05). 몇 개의 항목에서 유의 한 차이가 있더라도(p<0.05) 영상 모두 ACR MRI 팬텀 장비 정도 관리 기준에는 적합했다. 음압 수준 변화는 T1에서 15%, T2와 FLAIR에서 40%, DWI과 3D GE에서 70%의 감소 차이를 보였다. 결론적으로 DWI을 제외하고는 모든 영상에서 검사 시간의 차이 없이 동일한 영상의 화질을 획득할 수 있었다. 따라서 Comfortone 기법을 적용하여 소음은 현저하게 감소시키면서 동시에 임상적으로도 기존의 영상과 동일한 화질의 영상을 제공할 수 있을 것이다.
        4,000원
        6.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PartI of this paper identified the location and size of the noise sources from the axial flow fans, and partII based on that, identified the magnitude of sound pressure from the case and the blade according to frequency in the range of 2200 Hz to 5000 Hz. The equation of Lighthill was used for calculation. Generally, when measuring noise, the analytical area was extended more than 1m from the outlet of the fan. To eliminate the effects of backflow coming from the rear of the fan, the analytical area was extended a little longer than 1m. From the results of the analysis, high noise occurs in the low frequency area, and the lower noise becomes in the high frequency area. The maximum sound pressure generated in the range of 2000Hz~5000Hz is 65dB at a distance of 1m and 82dB at the outlet of the fan. Noise of the fan mainly occurred around the blade and guide, and the noise decreased as the frequency increased between 2200Hz and 3400Hz, but the noise increased as the frequency increased between 3800Hz and 5000Hz.
        4,000원
        8.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study is to predict the Sound Pressure Level(SPL) obtained from the Noble Close ProXimity(NCPX) method by using the Extended Kalman Filter Algorithm employing the taylor series and Linear Regression Analysis based on the least square method. The objective of utilizing EKF Algorithm is to consider stochastically the effect of error because the Regression analysis is not the method for the statical approach. METHODS: For measuring the friction noise between the surface and vehicle’s tire, NCPX method was used. With NCPX method, SPL can be obtained using the frequency analysis such as Discrete Fourier Transform(DFT), Fast Fourier Transform(FFT) and Constant Percentage Bandwidth(CPB) Analysis. In this research, CPB analysis was only conducted for deriving A-weighted SPL from the sound power level in terms of frequencies. EKF Algorithm and Regression analysis were performed for estimating the SPL regarding the vehicle velocities. RESULTS : The study has shown that the results related to the coefficient of determination and RMSE from EKF Algorithm have been improved by comparing to Regression analysis. CONCLUSIONS : The more the vehicle is fast, the more the SPL must be high. But in the results of EKF Algorithm, SPLs are irregular. The reason of that is the EKF algorithm can be reflected by the error covariance from the measurements.
        4,000원
        9.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The methods of measuring the sound from the noise source are Pass-by method and NCPX (Noble Close Proximity) method. These measuring methods were used to determine the linkage of TAPL (Total Acoustic Pressure Level) and SPL (Sound Pressure Level) in terms of frequencies. METHODS : The frequency analysis methods are DFT (Discrete Fourier Transform) and FFT (Fast Fourier Transform), CPB (Constant Percentage Bandwidth). The CPB analysis was used in this study, based on the 1/3 octave band option configured for the frequency analysis. Furthermore, the regression analysis was used at the condition related to the sound attenuation effect. The MPE (Mean Percentage Error) and RMSE (Root Mean Squared Error) were utilized for calculating the error. RESULTS: From the results of the CPB frequency analysis, the predicted SPL along the frequency has 99.1% maximum precision with the measured SPL, resulting in roughly 1 dB(A) error. The TAPL results have precision by 99.37% with the measured TAPL. The predicted TAPL results at this study by using the SPL prediction model along the frequency have the maximum precision of 98.37% with the vehicle velocity. CONCLUSIONS: The Predicted SPL model along the frequency and the TAPL result by using the predicted SPL model have a high level of accuracy through this study. But the vehicle velocity-TAPL prediction model from the previous study by using the log regression analysis cannot be consistent with the TAPL result by using the predicted SPL model.
        4,500원
        10.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The sound characteristics is changed by the cabin of the car which mount the speaker. Therefore the speaker must be design to consider the cabin of the car. In this study, the mechanical components of the nonlinear speaker model are investigated by measurement. The frequency characteristics of the sound and the sound pressure level for the same size speakers which are adapted to domestic car model(semi-mid size & mid size car) are investigated, too. From the measurement, we can investigate the differences of the sound characteristics and the thiele-small parameter such as force factor, mechanical mass of driver diaphragm, mechanical resistance of driver suspension losses and mechanical stiffness of driver suspension. This means that the speaker design parameters are changed by the car model
        4,000원
        12.
        2012.05 구독 인증기관·개인회원 무료
        최근 들어 음파를 이용한 작물의 해충 방제에 음파를 이용한 방제 연구가 시도되고 있다. 수컷의 구애노래를 이용하여 암컷을 포집하는 사운드 트랩(sound trap) 등에 관한 연구는 곤충의 소리를 이용하여 해충 방제에 활용하는 대표적인 방법으로 알려져 있다. 반면, 20 Hz 이하의 저주파 음은 해충 및 생물에게 스트레스를 발생시킬 수 있는 유해한 음으로 알려져 있다. 본 연구에서는 아메리카잎굴파리에 대한 저주파 음의 스트레스 효과를 조사하였다. 앰프 및 스피커(13 인치, 200 W)를 이용하여 20 Hz 사인파 순음을 음압에 따라 5일간 노출시켰다. 아울러 비교실험을 위해 실내에서 무음 상태로 우화율을 측정하였다. 86 dB에서의 아메리카우화율은 약 49%로 조사되었으나 67 dB 및 56 dB, 무음상태에서는 우화율이 80%로 차이가 나지 않았다. 본 연구를 통해 높은 음압의 저주파음은 아메리카잎굴파리 방제에 활용할 수 있을 것으로 예상된다.
        13.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 직물 소리의 주관적 감각을 결정하는 객관적 성질 중 가장 밀접한 관계를 지닌 것으로 보고되고 있는 물리적 음압 외에 직물 소리의 미세한 감각 차이를 설명할 수 있는 2차적 물성들을 규명하는 데에 있다. 3dB 이내의 유사 음압을 보이는 전통 견직물 다섯 종을 선택하여, 음향학적 물성치로 음색 요인인 δL과 δf, 심리음향학적 요인인 sharpness[z], roughness[z], fluctuation strength를 측정하고, 직물의 역학적 성질로서 Kawabata Evaluation System (KES)의 17개 물성을 측정하였다. 주관적 감각은 자유식강도측정법에 의하여 부드러움과 시끄러움을 포함한 7개 감각을 평가하였다. 연구 결과, 유사음압의 전통 견직물의 소리에 대한 주관적 감각 중 객관적 물성과 유의한 상관관계를 보이는 감각은 맑음과 거침, 높음이었다. 견직물 소리 간에 차이를 보인 맑음과 거침은 음색 요인인 δL에 의해 영향을 받아서, δL 값이 큰 직물일수록 소리가 더 맑고 덜 거칠게 느껴지는 것으로 나타났다. 또한 주관적인 높음은 roughness[z]와 δf와 유의적 상관관계를 나타내어, roughness[z] 값이 커질수록 또는 δf값이 작아질수록 소리가 더 높게 느껴지는 경향을 보였다. 따라서 유사음압의 전통 견직물의 소리 감각은 음압 외에 roughness[z]와 음색 요인들에 의하여 결정되며, 이를 전통 견직물의 소리 설계에 활용할 수 있을 것으로 기대된다.
        4,000원
        14.
        1985.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        1984년 7월 24일에서 동년 8월 2일까지 동해안과 울릉도를 항해중 정선하여 14개의 관측점에서 수심 5m~200m층을 관측한 해중소음의 음압레벨을 분석한 결과, 해중소음은 연안에서 멀리 떨어진 해역의 표층부근에서는 평균 1dB/16m의 비율로 수심이 깊어짐에 따라 낮아지는 경향을 나타내었으며, 정상적인 소음분포 형태를 이루고 있음을 알 수 있었다. 또한, 항구나 항만입구 부근에서는 육상소음의 영향을 받아, 단속적이고 지역적인 소음분포 형태를 이루고 있음과 해저지형과 해상에 따라서도 크게 변동됨을 알 수 있었다.
        4,000원
        15.
        1983.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선체의 횡요에 따른 물표입사음압의 변동한계를 조사하기 위하여, 선미식 트로올어선인 새바다호의 축적 1/50 FRP 모형선의 선저에 75 KHz용 초음파진동자를 부착시켜 음속축의 각변위에 따른 직접입사파음압의 변동을 이론적으로 고찰하고, 실험을 행한 결과를 요약하면 다음과 같다. 1. 선체의 횡요가 없을 때 선미선상에 대한 직접입사파음압의 분포는 좌우정횡선상 및 중앙선상의 그 분포보다 급격히 감소하는 현상을 나타내었다. 2. 선체의 횡요에 따른 직접입사파음압은 선미선상 및 중앙선상에서보다 좌측정횡선상에서 더 큰 변동을 나타내었다. 3. 음소축으로부터 좌즉횡선상으로 60cm되는 측정점에서의 음압변동률은 78.1로서 다른 측정점에서의 그 변동률보다 매우 컸으며, 각 측정점에 대한 직접파음압의 측정치와 계산치는 거의 일치하는 경향을 나타내었다.
        4,000원
        16.
        2017.12 서비스 종료(열람 제한)
        Acute upper airway obstruction can cause negative pressure pulmonary edema (NPPE). It is a well-known perianesthetic complication, but is uncommon for intubated patients. Radiation injury of lung can easily lead to pulmonary hemorrhage or NPPE caused by changes of transthoracic or transpulmonary pressure. It is due to injury of alveolar-capillary membrane by radiation. We report the case of a 71-year-old man with a history of radiation therapy for lung cancer after surgical resection who developed the abrupt onset of pulmonary hemorrhage and NPPE during general anesthesia for hydrocele and inguinal hernia operation.
        17.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 비접촉식 충격-반향 기법을 이용한 콘크리트 구조물의 손상 탐지에 있어서 비용 효율성을 높이기 위한 다이나믹 마이크로폰의 적용 가능성에 대하여 알아보았다. 박리 손상이 인공적으로 모사된 콘크리트 슬래브 실험체에 대하여 비접촉 충격-반향 실험을 다이나믹 마이크로폰을 이용하여 수행하였으며 저비용 센서 시스템의 손상 탐지 성능을 분석하였다. 실험 결과 다이나믹 마이크로폰으로 의미있는 신호의 측정이 가능하며, 또한 콘크리트의 박리 손상도 고성능 음압 센서만큼 명확하게 검출 가능하다는 것을 알 수 있었다.