검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 214

        81.
        2018.04 서비스 종료(열람 제한)
        The purpose of this study is to compare the ultrasonic pulse velocity before and after core compression test of steel fiber reinforced concrete using the ultrasonic pulse velocity method. The correlation between the column member ultrasonic pulse velocity before core test, the column member ultrasonic pulse velocity after core test, and the compressive strength of the core specimen were analyzed by fabricating a steel fiber reinforced concrete hollow column member.
        82.
        2018.04 서비스 종료(열람 제한)
        A notch beam test has been carried out for SFRC-SCC for precast slab tracks in accordance with BS-EN-14651. The steel fiber used is a product of Beckert, which is further processed with a general steel fiber and a steel fiber end(named as 3D, 5D). Overall, the crack behavior of the specimen using 5D fiber was superior to that of using 3D fiber
        83.
        2018.04 서비스 종료(열람 제한)
        This paper presents the mechanical properties of high performance fiber-reinforced concrete composites(HFCC) according to binder replacement rate. the compressive strength and single-axial tensile strength of HFCC were evaluated according to binder replacement rete. As a result of the test, the compression strength decreased as binder replacement rates increased, and B-20 mix properties expressed the most ideal tensile strain-stress curve.
        84.
        2018.04 서비스 종료(열람 제한)
        In this study, the absorption protection agent was applied to the surface of fiber reinforced concrete to evaluate the chloride ion penetration resistance. The evaluation was based on the method presented in KS F 2711. It was confirmed that the resistance performance against chloride ion was improved by 56∼71% when the coating material was applied.
        85.
        2018.04 서비스 종료(열람 제한)
        The joints in this construction are formed through the bonding shear evaluation method during the placement of ultra-high-performance concrete (UHPC). The evaluation items include push-off tests for homogeneous UHPC + UHPC. The experimental samples comprised a monolithic placement as the baseline, two levels for the separated placement according to the compression strength of concrete, and five levels for the interface treatment. The bonding shear performance for the homogeneous UHPC + UHPC construction linearly increased with the width and depth of the grooves used for the interface treatment. The increase in the number of grooves and their cross-sectional areas only slightly influenced the bonding shear performance. The optimal interface treatment method for the homogeneous UHPC + UHPC construction grooves was at least 30 mm.
        86.
        2018.04 서비스 종료(열람 제한)
        Effect of confining pressure on the shear strength of ultra-high-performance fiber-reinforced concrete (UHPFRCs) was investigated using a new shear test setup. Different confining pressures were applied and maintained to the specimens prior to shear testing. The shear strength of UHPFRCs was obviously sensitive to the confining pressure: the higher confining pressure produced higher shear strength. The confined shear strength could be expressed as a function of unconfined shear strength, confining pressure, and tensile strength.
        87.
        2017.12 KCI 등재 서비스 종료(열람 제한)
        프리캐스트 바닥판 공법은 바닥판간 이음부가 존재하며, 이음부의 연결성능에 따라 전체 교량 구조물의 성능이 좌우되므로 이음부 의 연결성능 확보가 중요한 요소이다. 본 연구에서는 고강도 강섬유보강콘크리트(High Strength Fiber Reinforced Concrete, HSFRC)가 적용된 비대칭 요철형 이음단면을 갖는 연결형식을 제안하였으며, 이음부의 단면형태, 철근 겹침이음길이 및 겹침이음 형식에 따른 구조실험을 수행 하여 제안된 연결형식의 휨 성능을 평가하였다. 실험결과, 이음부 상세에 관계없이 이음철근은 항복변형률 수준의 인장변형을 나타내었으며, 제안된 연결형식은 충분한 휨 저항성능을 확보하는 것으로 나타났다. 이러한 실험결과는, 현행 도로교설계기준의 최소 겹침이음길이에 대한 규정은 이음부 채움재로 HSFRC를 적용한 프리캐스트 바닥판 이음부에서는 보수적인 규정임을 알 수 있다. 따라서 이음부 채움재로 HSFRC 를 사용함에 의해 철근 겹침이음 상세의 단순화 및 이음부 폭의 감소가 가능하며, 제안된 연결형식은 프리캐스트 바닥판 이음부에 효과적으로 적용 가능할 것으로 판단된다.
        89.
        2017.11 서비스 종료(열람 제한)
        최근 소득 향상에 따른 레져 생활의 증가로 인해 해안가에 펜션, 리조트등 건축물을 많이 짓는 추세이다. 하지만 바닷가에 건물을 짓는다면 염분으로 인해 철근이 부식되어 건물의 내구성이 저하되기 때문에 이를 방지할 수 있는 새로운 콘크리트의 개발이 필요하다. 일반적으로 라텍스를 콘크리트에 혼입하게 되면 염분 및 수분의 침투에 대해 투수 저항성이 증가하고 수분증발 또는 흡수 등에 의한 건조수축 또는 팽창현상으로 인한 체적변화에 대해 안정성을 가지게 된다. 라텍스란 고무나무로부터 얻어지는 천연제품으로 반투명한 우유빛을 띠는 액체상태로서 콜로이드 같은 작은 구형의 유기체 폴리머입자가 물 속에 분산되어 있는 것을 말한다. 본 연구에 사용된 라텍스는 48%의 폴리머와 52%의 물로 구성된 Styrene-Butadiene계열이다. 라텍스는 유연성을 지니고 있고, 콘크리트 내부의 공극을 충진시켜주며 골재 주위에 필름막을 형성하지만 압축에 의한 파괴가 골재주위의 필름막에서 이루어져 라텍스 혼입률이 증가할수록 압축강도는 감소하는 것으로 판단된다. 이에 미세 강섬유를 보강 하면 콘크리트 내부에 국부적인 인장응력을 발생시켜 입자의 분산을 막아주기 때문에 압축강도가 개선된다. 따라서, 본 연구에서는 바닷가, 해안가에 사용이 가능하고 보통강도를 발현할 수 있는 콘크리트를 개발하고자 한다.
        90.
        2017.09 서비스 종료(열람 제한)
        The load-deflection curve and neutral axis changing curve, which were drawn by data from tests were analyzed. Both of steel fiber and reinforcing bar habe effect to induce the behavior of segmental U-shaped girder. The combination of 0.7% or 1.0% steel fiber and reinforcing bar sowed the effective ductle behavior of segmental U-shaped girder. The relationship of load-deflection and the crack pattern indicate that the appropriate combination are UFS1.0 and CFS1.0
        91.
        2017.09 서비스 종료(열람 제한)
        After the application of the formuar for the reinforcement index to the behavior of the UHPFRC box girders, reinforcement index does not determine the characteristic of behavior of UHPFRC box girder exactly. So the index should consider the dimension precisely and reference value corresponding to the 0.005 strain of the prestressing strands.
        92.
        2017.09 서비스 종료(열람 제한)
        The purpose of this study is to evaluate the effect of steel fiber reinforced concrete on structural performance when applied to joints. For this purpose, the development length was designed not to satisfy the concrete structure criterion. Experimental results show that the maximum strength of steel fiber reinforced concrete increases by about 12% in the direction of the settling force. Also, due to the increase of the tensile strength of the concrete, the strength of the cracks increased by 33% in the positive direction.
        93.
        2017.08 KCI 등재 서비스 종료(열람 제한)
        최근 거푸집 작업과 철근 배근 공정을 생략하여 공정의 단순화를 통한 공기단축 합성 슬래브 시스템의 개발 연구가 진행 중이다. 이 연구에서는 구조용 데크플레이트를 활용하여 거푸집 및 인장철근의 배근을 대체하고 강섬유보강 콘크리트를 사용하여 온도철근의 역할을 대 체하는 단순슬래브 시스템의 장기거동을 평가하는 것이 목적이다. 구조용 데크플레이트를 활용하는 기존 합성슬래브 공법은 건조수축에 의한 균열 제어를 위해 용접 철망을 배근하는 것이 일반적이나, 이는 균열을 억제하는 데 효과적이지 못한 것으로 선행연구들에서 지적되었다. 본 연구에서는, 일반적인 건축물의 하중 조건으로 제작 된 연속 두 경간을 갖는 강섬유보강 데크플레이트 슬래브의 장기적인 균열 및 처짐 거동을 평가하도록 하였다. 실험 결과, 실험체의 비 내력부에서는 장기균열의 개수 및 폭이 현저하게 감소하는 것으로 나타나 강섬유보강 콘크리트의 건조수축과 균열 제어 성능이 우수한 것으로 평가되었으며,,처짐량도 강섬유보강 데크플레이트 슬래브가 우수한 것을 확인하였다. 다만, 부모 멘트가 작용되는 슬래브 연속단부에서는 사용하중 단계에서 균열폭을 제어하고 하중 제거 시 처짐을 회복하기 위한 디테일의 적용이 필요한 것으로 분석되었다.
        94.
        2017.04 서비스 종료(열람 제한)
        This paper provides the flexural test results of steel fiber reinforced concrete (SFRC) prisms with different aspect ratios of steel fibers (60 and 67). All mixtures have specific compressive strength of 40 MPa and steel fiber volume fraction of 0.75%. According to ASTM C 1609 and EN-14651, SFRC prisms with 150×150×550 mm were made and tested under bending loading. Test results indicated that the aspect ratio of hooked-end steel fibers has insignificant effect on the first-cracking strength and flexural behavior of SFRC prisms.
        95.
        2017.04 서비스 종료(열람 제한)
        This paper presents the flexural test results of steel fiber reinforced concrete (SFRC) prisms with different lengths of steel fibers. The specified compressive strength of SFRC is 40 MPa. Two types of steel fiber used in this study have lengths (0.5 and 0.9mm). Test results indicated that steel fibers with longer length is more effective to improve the flexural performance of concrete prisms than steel fibers with shorter length.
        96.
        2017.04 서비스 종료(열람 제한)
        This study performed gas-gun propelled projectile impact tests with high strength steel fiber reinforced concrete. Also, from the impact tests, failure modes and protection performances of HIgh Performance Concrete which is reinforced by steel fibers were assessed. High strength steel fiber reinforced concrete showed excellent protection performances against impact loads.
        97.
        2017.04 서비스 종료(열람 제한)
        Recently, fiber-reinforced concrete has been commonly applied to floor slabs. Therefore, this study introduces a program that can determine an optimum content of fibers incorporated in concrete accounting for the flexural and punching shear capacities, as well as serviceability conditions in the design of fiber-reinforced concrete floor slabs.
        98.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        This paper provides the flexural test results of steel fiber reinforced concrete (SFRC) prisms with different aspect ratios of steel fibers (60 and 67). All mixtures have specific compressive strength of 40 MPa and steel fiber volume fraction of 0.75%. According to ASTM C 1609 and EN-14651, SFRC prisms with 150×150×550 mm were made and tested under bending loading. Test results indicated that the aspect ratio of hooked-end steel fibers has insignificant effect on the first-cracking strength and flexural behavior of SFRC prisms.
        99.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        This paper presents the flexural test results of steel fiber reinforced concrete (SFRC) prisms with different lengths of steel fibers. The specified compressive strength of SFRC is 40 MPa. Two types of steel fiber used in this study have lengths (0.5 and 0.9mm). Test results indicated that steel fibers with longer length is more effective to improve the flexural performance of concrete prisms than steel fibers with shorter length.
        100.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        시멘트 생산 과정에서 생성되는 이산화탄소 배출량을 감소시키기 위하여 시멘트를 대체할 수 있는 건축 재료 개발에 많은 연구가 진행되어왔다. 시멘트 대체재로 사용될 수 있는 활성 황토는 850°C에서 소성 과정을 거쳐 제작된다. Poly-Vinyl Alcohol(PVA) 섬유와 GFRP 보강근은 활성 황토 콘크리트의 균열 문제를 해결하기 위하여 사용된다. 본 논문은 PVA 섬유 보강 활성 황토 콘크리트에 대하여 인발 하중에 따른 GFRP 보강근의 부착 성능을 평가하기 위한 실험 연구를 나타내고 있다. 실험 결과, 황토가 치환된 PVA 보강 및 무보강 실험체들의 평균 부착 응력 계수가 2.27~2.48로 나타났으며, 부착 응력 계수가 PVA 섬유 보강 유무 및 황토 치환율에 크게 영향을 받지 않는 것으로 나타났다. 그리고 부착 길이가 길어질수록 부착 강도는 저하되었다.
        1 2 3 4 5