        검색결과 393

        41.
        2018.05 구독 인증기관·개인회원 무료
        본 연구에서는 해수를 유도용액으로 사용하고 하수처리수를 공급수로 사용하는 정삼투막 공정의 유기/바이오 오염물에 의한 막오염을 저감하기 위해 폴리도파민/탄소 나노 튜브 복합 분리막을 제작하였다. 분리막은 기존 계면중합반응에 탄소 나노 튜브를 첨가하여 초박형 복합 분리막을 제조한 후, 폴리도파민으로 코팅시켜 제조하였다. 제작 된 분리막은 알긴산나트륨(Sodium alginate)용액과 미생물(Pseudomonas aeruginosa PA01) 부착 실험을 통하여 수투과도와 막오염도를 평가하였다. 그 결과, 폴리도파민/탄소 나노 튜브 복합 분리막은 복합되지 않은 분리막에 비하여 높은 수투과도와 낮은 막오염 성능을 보였다.
        42.
        2018.05 구독 인증기관·개인회원 무료
        In this study, various physical cleaning methods such as physical washing and osmotic backwash, were conducted to understand membrane fouling properties by employing real secondary wastewater effluent (SWWE). In addition, microfiltration (MF) and ultrafiltration (UF) pretreatments were compared to maximize removal of organic matter and to control membrane fouling efficiently. Organic foulants deposited on the active layer of FO membrane were observed by fouling behavior test. The relationship between concentrations of natural organic matter and membrane fouling was also investigated from the bench-scale FO tests.
        43.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effect of chemically enhanced backwash(CEB) coping with algal(Heterosigma Akashiwo) inflow was evaluated in the seawater desalination pretreatment process using ceramic membrane. In order to confirm the possibility of long-term filtration operation, the recovery rate of transmembrane pressure(TMP) due to the CEB using NaOCl was examined. When the membrane flow rate was 83.3 LMH, the TMP was maintained within 200 kPa for 84 hours in seawater influent. As the algal counts of 30,000 cell/mL were injected into the influent of seawater, however, the TMP rapidly increased and exceed maximum value. Membrane fouling caused by the algae was very poorly recovered by usual physical backwash. The CEB was performed for 30 min(3 min circulation / 27 min immersion) with 300 mg/L of NaOCl. As a result of the CEB application, it was possible to maintain a stable operating of filtration during 10 days and the average recovery rate of TMP by the CEB was 98.1%. It has been confirmed that the CEB using NaOCl is very effective in removal of membrane fouling by algae, resulted in stable membrane filtration for the long-term operation.
        4,000원
        44.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effects of operating conditions on the formation of reversible and irreversible fouling were investigated in the filtration using ceramic membrane for water treatment process. The effect of coagulation pretreatment on fouling formation was also evaluated by comparing the performance of membrane filtration both with and without addition of coagulant. A resistance-in-series-model was applied for the analysis of membrane fouling. Total resistance (RT) and internal fouling resistance (Rf) increased in the membrane filtration process without coagulation as membrane flux and feed water concentrations increased. Internal fouling resistance, which was not recovered by physical cleaning, was more than 70% of the total resistance at the range of the membrane flux more than 5 m3/m2・day. In the combined process with coagulation, the cake layer resistance (Rc) increased to about 30-80% of total resistance. As the cake layer formed by coagulation floc was easily removed by physical cleaning, the recovery rate by physical cleaning was 54~90%. It was confirmed from the results that the combined process was more efficient to recover the filtration performance by physical cleaning due to higher formation ratio of reversible fouling, resulted in the mitigation of the frequency of chemical cleaning.
        4,200원
        45.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the effects of blanching time (1-5 min), types of blanching solution (1% NaCl vs 1-3% sucrose), addition of packaging with blanching solution, and thawing methods (thawing in packaged versus depackaged units) on the qualities of frozen Aster scaber. As quality parameters, drip loss, moisture content, shear force, color, and sensory test were conducted. Aster scaber was blanched in 1% sucrose for 4 min and packaged with the same solution prior to freezing whereas frozen Aster scaber exhibited palatable quality when it was removed from the package and thawed in running water. Consequently, this study demonstrated that the optimized processing condition provided qualities like non-frozen control.
        4,000원
        46.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In water treatment process using microfiltration membranes, manganese is a substance that causes inorganic membrane fouling. As a result of analysis on the operation data taken from I WTP(Water Treatment Plant), it was confirmed that the increase of TMP was very severe during the period of manganese inflow. The membrane fouling fastened the increase of TMP and shortened the service time of filtration or the cleaning cycle. The TMP of the membrane increased to the maximum of 2.13 kgf/cm2, but it was recovered to the initial level (0.17 kgf/cm2) by the 1st acid cleaning step. It was obvious that the main membrane fouling contaminants are due to inorganic substances. As a result of the analysis on the chemical waste, the concentrations of aluminum(146-164 mg/L) and manganese(110-126 mg/L) were very high. It is considered that aluminum was due to the residual unreacted during coagulation step as a pretreatment process. And manganese is thought to be due to the adsorption on the membrane surface as an adsorbate in feed water component during filtration step. For the efficient maintenance of the membrane filtration facilities, optimization of chemical concentration and CIP conditions is very important when finding the abnormal level of influent including foulants such as manganese.
        4,200원
        47.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 막 결합형 축전식 탈염공정의 단위셀의 단수를 늘려 적층된 10단 형태의 모듈을 설계하여 제작하 였다. 아민기가 함유된 폴리설폰(APSf)과 술폰기가 함유된 폴리이서이서케톤(SPEEK)을 합성하였으며 캐스팅법으로 다공성 탄소전극에 코팅하여 제조하였다. 10단 모듈에 대하여 흡착전압 및 시간, 탈착전압 및 시간, 공급액의 유속과 농도 등의 운전 조건과 CaSO4, MgCl2 등의 2가 이온 용액과 수도수에 대하여 염 제거효율을 측정하였다. 대표적으로 NaCl 100 mg/L의 공급 액을 사용하였을 때, 유속 100 mL/min, 흡착조건 1.2 V/3 min, 탈착조건 -0.5 V/5 min에서 98.3%의 염 제거효율을 보였다.
        4,000원
        48.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pulp and paper industry produces large volumes of wastewater and residual sludge waste, resulting in many issues in relation to wastewater treatment and sludge disposal. Contaminants in pulp and paper wastewater include effluent solids, sediments, chemical oxygen demand (COD), and biological oxygen demand (BOD), which should be treated by wastewater treatment processes such as coagulation and biological treatment. However, few works have been attempted to predict the treatment efficiency of pulp and paper wastewater. Accordingly, this study presented empirical models based on experimental data in laboratory-scale coagulation tests and compared them with statistical models such as artificial neural network (ANN). Results showed that the water quality parameters such as turbidity, suspended solids, COD, and UVA can be predicted using either linear or expoential regression models. Nevertheless, the accuracies for turbidity and UVA predictions were relatively lower than those for SS and COD. On the other hand, ANN showed higher accuracies than the emprical models for all water parameters. However, it seems that two kinds of models should be used together to provide more accurate information on the treatment efficiency of pulp and paper wastewater.
        4,000원
        49.
        2017.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Boron-doped diamond (BDD) electrode has an extremely wide potential window in aqueous and non-aqueous electrolytes, very low and stable background current and high resistance to surface fouling due to weak adsorption. These features endow the BDD electrode with potentially wide electrochemical applications, in such areas as wastewater treatment, electrosynthesis and electrochemical sensors. In this study, the characteristics of the BDD electrode were examined by scanning electron microscopy (SEM) and evaluated by accelerated life test. The effects of manufacturing conditions on the BDD electrode were determined and remedies for negative effects were noted in order to improve the electrode lifetime in wastewater treatment. The lifetime of the BDD electrode was influenced by manufacturing conditions, such as surface roughness, seeding method and rate of introduction of gases into the reaction chamber. The results of this study showed that BDD electrodes manufactured using sanding media of different sizes resulted in the most effective electrode lifetime when the particle size of alumina used was from 75~106 μm (#150). Ultrasonic treatment was found to be more effective than polishing treatment in the test of seeding processes. In addition to this, BDD electrodes manufactured by introducing gases at different rates resulted in the most effective electrode lifetime when the introduced gas had a composition of hydrogen gas 94.5 vol.% carbon source gas 1.6 vol.% and boron source gas 3.9 vol.%.
        4,000원
        50.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae’s harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as ① ACF (Algae Coagulation·Flotation) process using natural algae coagulant (Water Health®), ② ACF + C/S process and ③ C/S process with a variety of conditions using cultured algae. The average values of turbidity were ① 0.42 NTU for ACF process, ② 0.13 NTU for ACF + C/S process and ③ 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of ① ACF or ② ACF + C/S could be one of the effective and alternative solutions.
        4,300원
        51.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate and compare the change of wind velocity and processing efficiency of sulfuric compounds and more complex odors. The research was conducted in a facility specializing in odor prevention applications using upgraded existing research equipment (from 30 CMM to 200 CMM) on wastewater treatment. The research equipment was installed with the purpose of removing odor from the wastewater treatment (Pasteur Factory) located in Hoengseong-gun, GangWon. To investigate the treatment efficiency of hydrogen sulfide test samples were evaluated with different blower installation positions and changes in wind speed. The wind speed at the static pressure is about 1.70~2.08 times faster than that of the static pressure, although the blower power is different. The efficacy of sulfur compounds and complex odor treatment was 91.27% and 95.20%, respectively. The study results show that it is necessary to review the design point of wind speed due to the increase in facility scale. In addition, considering the characteristics of complex odor, it is necessary to consider additional surcharges. It was determined that the facility plan for odor prevention in relation to wind velocity will be reexamined. Ongoing research will also be considered to help identify any disadvantages and solutions for the ventilator positioning, which is currently installed in the back.
        4,000원
        52.
        2016.11 구독 인증기관·개인회원 무료
        역삼투 해수담수공정의 전처리로 CO2 가스하이드레이트를 이용한 급속동결담 수(HIID)공정의 가능성 평가를 목적으로 실험을 진행하였다. CO2 가스하이드레 이트는 가압된 CO2가스를 GUEST로 사용하여 만들어지는 얼음형태의 결정을 의미하며, 이때, 가압된 압력을 상압으로 감압하게 되면 흡열반응이 진행되어 온도가 급감하게 된다. HIID공정은 이 온도감소를 구동력으로 해수를 동결하였다. 이 전처리된 해수를 225psi로 역삼투막을 6시간 저압 운전시 수투과도가 14 LMH이상, 제거율이 98.5-99%로 관찰되었다. 이 실험으로 HIID공정이 역삼투공 정의 전처리로 사용가능함을 확인하였으며, 후단의 역삼투공정에서 운전하는 압력을 기수조건으로 가능하게 하였다. 이를 통해 저비용으로 해수담수가 가능함 을 확인하였다.
        53.
        2016.11 구독 인증기관·개인회원 무료
        최근 셰일가스 산업의 호황과 더불어 셰일가스전에서 배출되는 폐수처리가 중요한 환경문제로 부각되고 있다. 셰일가스전 폐수는 총 용존고형물의 농도가 10에서 200g/L로 높기 때문에 역삼투 담수공정을 적용하기에 어려움이 있다. 본 연구에서는 셰일가스전 폐수를 처리하기 위해 저압에서 운전 가능한 정삼투 공정(FO)의 적용 가능성을 연구하였다. 특히 대표적으로 널리 활용되고 있는 유도용액인 NaCl과 NH3-CO2를 사용하여 셰일가스전 폐수에 포함되어 있는 2가 양이온이 FO공정에 미치는 영향을 알아보았다. FO공정 유도용액의 역확산은 막의 플럭스와 스케일로 인한 막오염에 중요한 영향을 끼치는 것으로 나타났다. 이를 통해 FO공정의 폐수 성상에 따라 유도용액 종류 선택 및 공정 디자인의 중요성이 입증되었다.
        54.
        2016.11 구독 인증기관·개인회원 무료
        최근 막여과 정수처리에 대한 관심이 높아지고 있으나, 공정설계를 위한 소프트웨어가 널리 보급되어 있지 않아서 현장적용의 어려움이 발생하고 있다. 본 연구에서는 막여과 정수처리 공정설계를 지원할 수 있는 프로그램과 설계기법을 개발하고자 하였다.
        55.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was begun with the object of actively reflection the rapid technological advancements of the electronical control and mechanical control industries to sewage disposal methods. Or focuses on applying a flow control method that utilizes inverters and automatic valves to sewage treatment process systems.This study proposes that sewage treatment process systems architects must acquire a certain degree of technical skills in the areas of electrical and mechanical controls in order to raise the standard of completeness of sewage treatment process systems. And further emphasizes that there is required continuous research on automatics valves that are used in sewage treatment.
        4,000원