검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 148

        21.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        National concerns about air pollution are growing. The importance of indoor air quality is emerging because people live in an indoor environment more than 90% of the day. In particular, the indoor air quality of schools needs to be managed as teenagers are vulnerable to environmental pollution. The government has designated the School Health Act in order to manage indoor air quality in schools. Air purifiers have been operated to improve indoor air quality in the classroom since 2018. In this study, we performed on-site evaluations in some classrooms, and then we proposed a plan for improving the air quality in the classroom. In this study, PM10, PM2.5, and CO2 in classrooms in Chungnam were measured to analyze the effect of air cleaner supply. A portable aerosol spectrometer (PAS, model 1.109, Grimm) and CO2 meter (TES 1370, TES) were used as measuring instruments. Schools A and B exceeded the recommended standards, while school C met the standards. The ratio of PM10, PM2.5 in classrooms A and B was 0.58 and 0.5, respectively. Correlation analysis was performed between indoor and outdoor pollutants to analyze the effects of particulate pollutants present in each classroom. First, the measured concentration of fine particles was classified according to/on the basis of factors that affect/influence the internal environment of the classroom. Then, fine dust concentrations measured at the same time as AQMS were classified with regard to the external factors. The gradients for each classroom were 1.57, 1.63, and 1.54, although there were differences in concentration, but they were relatively similar. It is necessary to develop and disseminate customized air purifiers considering the activity of the occupants of classrooms. It is important to consider the areas in which s tudents breathe when installing air purifiers in the classroom. In addition, follow-up management of air purifiers is an essential element. For efficient operation and management of indoor air quality, it is necessary to develop and disseminate standard manuals for air purifiers. It is proposed that an environmental manager should be deployed in schools to manage environmental issues. Standardization of air purifiers, management guidelines for standard manuals, and field support for environmental sheriffs should be established on a legal basis.
        4,300원
        22.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aimed to assess the pollution level in 13 crowded subway stations in an effort to understand the spatial and seasonal factors of Indoor Air Quality. The main measured items were particulate pollutants such as PM10 and PM2.5 and gaseous pollutants such as CO2, HCHO, Rn, TVOC, BTEX, and Styrene at concourses and platforms in the summer and winter periods. The influence of the draught created by the movement of the train was classified into lateral and island platforms, and the concentrations of PM by location (entrance, middle, and end) were statistically compared and analyzed. As a result, the concentrations of PM were confirmed high in the order of Platform > Concourse > Ambient air. In particular, in the case of platform PM10, the frequency exceeding the standard value (100 μg/m3) was 38.5% and the maximum concentration was 196.2 μg/m3. All gaseous pollutants were at lower levels than the standard, and the factors affecting CO2 and Rn were identified as the number of users and geological characteristics, respectively. The principal component analysis (PCA) demonstrated that PM was found to be a major indicator of the air quality management of subway stations. In particular, the concentrations at entrance and end areas in the lateral platform were about 1.4 times higher with regard to PM10 than in the middle area, and about 1.9 times higher with regard to PM2.5 due to the effect created by the draught produced by the movement of the train. Therefore, in order to manage PM in the platform area, a specialized management plan for places with particularly high PM concentration within the platform area is required. In addition, it is necessary to evaluate the effect created by the draught produced by train movement when selecting locations for measuring indoor air quality.
        4,000원
        24.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The emission of particulate matter and volatile organic compounds (VOCs) from a motor vehicle painting booth was quantitatively evaluated. Most particulate matter was emitted during the spraying process, in which the PM10 concentration was 16.5 times higher than that of the drying process. When the paint was being sprayed, the particles with a diameter of 1.0~2.5 μm accounted for 39.4% and particles greater than 2.5 μm in diameter accounted for 30.6% of total particles. On the other hand, small particles less than 0.5 μm in diameter accounted for 52.4% of total particles during the drying process. In contrast to the particulate matter, high concentrations of VOCs were emitted during both spraying and drying processes. Butyl acetate, xylene, toluene, and m-ethyltoluene were the most abundant VOCs emitted from the motor vehicle painting booth. Additionally, xylene, butyl acetate, toluene, and 1,2,3-trimethylbenzene were the dominant ozone precursors. Especially, xylene exhibited the highest ozone production contribution (32.5~44.4%) among 34 species of the ozone precursors. The information obtained in this study can be used to establish a suitable management strategy for air pollutants from motor vehicle painting booths.
        4,200원
        25.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effect of improving indoor air quality according to the installation of plants was evaluated in classrooms where students spend much time. The purpose was to prepare sustainable and eco-friendly measures to improve the indoor air quality of school classrooms. A middle school in Bucheon was selected as an experiment subject, and IAQ monitoring equipment based on IoT was installed to monitor indoor air quality. After measuring the basic background concentration, plants and air purifiers were installed and the effects of improving indoor air quality using plants and air purifiers were evaluated based on the collected big data. As a result of evaluating the effects of indoor air quality improvement on the installation of plants and air purifiers, the reduction rates of PM10 and PM2.5 in descending order were plant- and air purifier- installed classes, air purifier-installed classes, and plant-installed classes. CO2 levels were reduced in the classrooms with only plants, and increased in two classrooms with air purifiers. The increase in CO2 concentration in the classrooms with plants and air purifiers was lower than in those with only air purifiers.
        4,600원
        26.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we conducted a survey to reveal the general perception of parents toward outdoor air quality, particulate matter (PM), and indoor air quality (IAQ) at schools where their children attend. A total of 1,030 parents participated in this survey, where the age of their children ranged between 7 years to over 19 years of age. Each participant was either a member of a non-governmental organization (NGO) with a keen interest in air quality or an ordinary public panel member with less interest. The result of the survey indicated that the participants had a negative perception of air quality, and parents believed that the outdoor and indoor air is extremely polluted. The participants pointed out that they believe that the main reason for the pollution is due to particulate matter (PM) and school classrooms are the location where their children are exposed to PM the most. Based on our study, the majority of the participants prefer a mechanical ventilation system to reduce indoor air pollutants in schools. Our study should be referred to by school officials in order to maintain IAQ and as a way of addressing the concerns of parents who want to protect their children’s health.
        4,000원
        27.
        2020.11 구독 인증기관 무료, 개인회원 유료
        Actively promoting pro-environmental behavior not only can effectively reduce degree of environmental pollution, but also is a necessary step for the sustainable development of social economy. Although scholars have had in-depth discussions on influencing factors and promoting mechanism of pro-environmental behavior, research concerning effects of external situational factors on pro-environmental behavior is relatively insufficient, and impacts of natural environment conditions, say, air quality is seldom considered. With the development of China’s economy, industrial growth and advancing urbanization, air quality continues to deteriorate when acid rain, haze and other harsh weathers occur more frequently, seriously affecting and endangering people’s health and daily life. So, does air quality also affect people’s pro-environmental behavior? And if so, how is that impact? What is the internal mechanism? Based on the above questions, this paper designed two studies, in combination with spatial distance, and explored the impacts of air quality on Chinese residents’ pro-environmental behavior. It also demonstrated the internal impact mechanism from the perspective of environmental emotion, and expanded research on impact mechanism of air quality on pro-environmental behavior.
        4,000원
        28.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effects of heat-moisture treatment (boiling or steaming for 45 min) prior to hot air drying (70 o C for 8 h) on water activity (Aw), moisture (MC), Brix, color, and texture of dried sweet potato slices were investigated to identify the best pretreatment condition for producing dried sweet potato with the best eating quality. Dried sweet potato slices pretreated by boiling (BL) showed significantly lower Aw, MC, and hardness while Brix was significantly higher than with steaming (ST) treatment. There were no significant differences for the color, springiness, cohesiveness, gumminess, and brittleness indexes. At 8 h drying, the Aw, MC, Brix, and hardness of the BL and ST samples were 0.81 and 0.82, 19.71% and 25.53%, 53.80% and 49.40%, and 20.49 kg/cm 2 and 31.98 kg/ cm 2 , respectively. This information will be useful for manufacturers in the production of dried sweet potato slices. These findings provide evidence of the feasibility of heat-moisture treatments in the production of dried sweet potato.
        4,000원
        30.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The topic of indoor air quality has attracted great interest since urban dwellers spend over 90% of their time indoors, such as public facilities, public transport and homes. In this study, the changes and current status of indoor air quality management and improvement policies for public facilities in Korea were discussed. Furthermore, we investigated the concentration and contamination status of indoor air pollutants based on the indoor air quality guidance and inspection report from 2007-2017 published by the Ministry of Environment, Korea. As a result, we found that while the PM10 concentration in public facilities decreased consistently, there was no clear change in the CO2 concentration. The HCHO concentrations were high in museums, art galleries, and postpartum centers, etc. The child care centers showed a high concentration of TCB. In conclusion, we suggested that it is necessary to focus on target substances according to the type of facility to manage indoor air quality efficiently. Intensive management and monitoring are particularly needed in child care centers to improve the indoor air quality.
        4,000원
        31.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to provision the standard method for ensuring the reliability of measuring indoor air quality in public transportation. The objective is to determine the difference in the measured concentration values according to various conditions. These variables include measurement conditions, measurement equipment, measurement points, and measurement time. The value differences are determined by measuring the PM10 and CO2 concentration of subways, and express buses and trains, which are targets of indoor air quality management. The concentration of CO2 was measured by the NDIR method and that of PM10 was measured by the gravimetric method and light-scattering method. Statistically, the results of the concentration comparison according to the measurement points of the public transportation modes were not significantly different (p > 0.05), and it is deemed that the concentration is not affected by the measurement points. In terms of the concentration analysis results according to the measurement method, there was a difference of the concentration between the gravimetric and light scattering method. In the case of the light scattering method, the concentration differed depending on whether it was corrected with standard particles in the laboratory environment.
        4,200원
        32.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The concentrations of volatile organic compounds (VOCs) and odor-inducing substances were measured using selected ion flow tube mass spectrometers (SIFT-MS) and a drone equipped with an air quality monitoring system. SIFT-MS can continuously measure the concentration of VOCs and odor-inducing substances in realtime without any pre-treating steps for the sample. The vehicle with SIFT-MS was used for real-time measurement of VOC concentration at the site boundaries of pollution sources. It is possible to directly analyze VOCs concentration generated at the outlets by capturing air from the pollution sources with a drone. VOCs concentrations of nine spots from Banwol National Industrial Complex were measured by a vehicle equipped with SIFT-MS and were compared with the background concentration measured inside the Metropolitan Air Quality Management Office. In three out of the nine spots, the concentration of toluene, xylene, hydrogen sulfide, and methyl ethyl ketone was shown to be much higher than the background concentration. The VOCs concentrations obtained using drones for high-concentration suspected areas showed similar tendencies as those measured using the vehicle with SIFTMS at the site boundary. We showed that if both the drone and real-time air quality monitoring equipment are used to measure VOCs concentration, it is possible to identify the pollutant sources at the industrial complex quickly and efficiently check sites with high concentrations of VOCs.
        4,000원
        33.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Smoking is a disservice to not only for smokers who smoke, but also for nonsmokers due to smoke or smell. In particular, smoking harms health by increasing the discomfort associated with the smell generated by burning the cigarette, and giving rise to lung injury or cancer caused by smoke inhalation. The purpose of this study was to investigate the characteristics of various concentrations of nicotine, PM2.5, and heavy metals (As, Cr, Cd, Pb) generated by smoking according to the smoking intensity. When smokers smoked continuously, the amount of nicotine, PM2.5, Cr, and Cd produced by smoking increased proportionally and became statistically significant. However, As and Pb showed a different pattern from other materials, and the concentration increased by 2~3 times when 10 cigarettes were smoked. As for the change in PM2.5 for 12 hours immediately after smoking, about 70% of the particles were deposited on the floor or wall even in a sealed room where no ventilation was available, and the concentration naturally decreased. However, the remaining particles were found to remain in the air even though the time passed exceeded 12 hours.
        4,000원
        34.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A survey on the indoor air quality of schools was conducted on a total of 10 schools in each location, such as industrial zones, roadside zones and clean zones of the Jeonbuk Province. Regardless of their location, 75% of the schools were not suitable to the environmental standard, and five schools were inadequate in both the first and the second half measurement results. Compared to the public facilities survey conducted by the Jeollabukdo Institute Health and Environment Research from 2008 to 2016, the concentration of CO2, total airborne bacteria (TAB), and PM10, with the exception of HCHO, was higher in school classrooms than in any other public facilities. The correlations between pollutants and test items demonstrated that total airborne bacteria (TAB) were significantly correlated with the degree of ventilation, and the PM10 was correlated with the cleaning status, respectively. Although the other test items of indoor air quality in the school were measured in the same way as the public facilities measurement methods, the PM10 is applied in accordance with the simplified method. In order to investigate the difference between the measurement methods, the results were compared at the same point at the same time. When comparing the concentrations of PM10, the gravimetric method, which is a public facilities measurement method, showed a significant difference from the light scattering method, which is a method of measuring PM10 in schools. By comparison, it was confirmed that the light scattering method was measured lower than the gravimetric method. The light scattering method is useful for confirming the change of the particulate matter, but it is considered difficult to judge the concentration of the particulate matter in the classroom by the instantaneous measurement because of the potential error caused by high humidity, etc. Secondary pollution ions were measured at 17.1% ~ 40.5% in the industrial zone schools, 7.4%~27.4% in the roadside zone schools and 8.1%~21.8% in the clean zone schools, The percentage of pollution ions were not clearly distinguished by location.
        4,200원
        35.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to investigate the potential of infrared assisted air drying (IRAD) to dry dorumuk (Arctoscopus japonicus). The IRAD system is composed of a far infrared lamp, convection fan, data loggable electronic balance, and proportional-integral-differential temperature controller. The infrared lamp provided radiative energy for temperature increase and substance moisture vaporization. The convection fan removed the moisture outside the drying chamber. Various IRAD conditions were tested at 40oC & 5 m/s, 40oC &11 m/s, 50oC & 5 m/s, 50oC & 11 m/ s, 60oC & 5 m/s, or 60oC & 11 m/s. The IRAD of 40oC & 5 m/s could reduce the moisture content by 42.2 %. The IRAD of 60oC and 11 m/s could further reduce the moisture content to 16.7% within 17 h. During the IRAD test, electrical energy consumption ranged from 1.16 to 1.38 kWh which is lower than that of hot air drying. IRAD resulted in dried dorumuk with yellow color and crispy texture. In this study, IRAD showed potential for the production of high-quality, dried dorumuk products.
        4,000원
        36.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate the effect of shoe dust on the indoor environment, and the effectiveness of shoe dust control on indoor air quality. Test dust was resuspended to reach a mass concentration of particles (2.5-10 μm size) more than 3 times compared to background level, and 1.5 times for particles less than 1 μm in size. The shoes, which were used for actual walking purposes in the outdoor environment, increased indoor PM10 concentration by 118±9%. The removal of shoe dust by water washing and mechanical suction brought about an improvement of indoor air quality. In particular, in circumstances where 27 people walked for one hour into the indoor environment, the mechanical suction of shoe dust decreased PM10 concentration by about 17% (based on the mass balance analysis).
        4,000원
        37.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As indoor activities continue to increase, the importance of indoor air is emphasized. Moreover, children's activities are emphasized as being vulnerable. In this study, vocal organic compounds (VOCs) and CO2 in the indoor air were analyzed among children aged 4 to 7 years attending day care centers in Seoul. In the case of VOCs, the average concentration measured during a period of 24 hours in an asthmatic home was 143.9 (μg/m3). The average concentration measured during a period of 24 hours in the asthma and rhinitis home was 146.7 (μg/m3). In CO2, the average concentration measured during a period of 24 hours in the asthmatic home was 665.9 (ppm). The average concentration measured during a period of 24 hours in the asthma and rhinitis home was 695.9 (ppm). In this study, asthma symptoms increased as the concentration of indoor pollutants increased. Exposure of VOCs (μg/ m3) and CO2 (ppm) among environmental factors shows that respiratory symptoms such as asthma can be induced.
        4,000원
        38.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the CO2 and PM10, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The PM10 concentration increased due to outdoor air intake; however the CO2 concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except PM10 can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.
        4,000원
        39.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we measured the concentration of Particulate Matter(PM10), Formaldehyde(HCHO), and Total Bacteria Count (TBC) at two facilities: day care centers, and postnatal care centers located in the cities of Gyeonggi, Gangwon, Jeolla and Gyeongsang from January 1, 2012 to December 31, 2015. PM10 concentration was similar to the day care centers and postnatal care centers. HCHO concentration was the highest in the postnatal care centers. TBC concentration was the highest in the day care centers. Comparing the different cities, PM10 concentration was the highest in Gyeonggi, HCHO concentration was the highest in Gyeonggi, and TBC concentration was the highest in Gyeonggi. As a result of HCHO's risk assessment, it was found that adults exceeded the carcinogenicity tolerance of 10−6 specified by the US EPA. This study is expected to be helpful in preventing damage to health from the contaminated indoor air at sensitive facilities, and can be used as basic data for indoor air quality management.
        4,000원
        40.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigate a seasonal underground market which is located under a semi-enclosed basement. Under such settings, there is difficulty in managing indoor air quality such as ventilation. Based on the result, we can improve the indoor air environment of the underground market. The underground market in Seoul was divided into four types according to its structural characteristics and the seasonal survey was conducted. In conclusion, we will develop a realistic improvement plan to improve the indoor air environment of the underground market by selecting the underground market through actual survey.
        4,000원
        1 2 3 4 5