        61.
        2015.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the moment frame subjected to earthquake loads, beam-column joint is structurally important for ductile behavior of a system. ACI Committee 352 proposed guidelines for designing beam-column joint details. The guidelines, however, need to be updated because of the lack of data regarding several factors that may improve the performance of joints. The purpose of this study is to investigate the seismic performance of reinforced concrete exterior joints with high-strength materials and unbonded tendons. Three specimens with different joint shear demand-to-strength ratios were constructed and tested, where headed bars were used to anchor the beam bars into the joint. All specimens showed satisfactory seismic behavior including moment strength of 1.3 times the nominal moment, ductile performance (ductility factor = at least 2.4), and sufficiently large dissipated energy.
        4,000원
        63.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The torque shear high strength bolt is clamped normally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the required tension, as it considerably fluctuates due to torque coefficient dependent on lubricant affected temperature. In this study, the clamping tests of torque shear bolts were conducted independently at indoor conditions and at construction site conditions. During last six years, temperature of candidated site conditions was recorded from -11℃ to 34℃. The indoor temperature condition was ranged from -1 0℃ to 50℃ at each 10℃ interval. As for site conditions, the clamping force was reached in the range from 159 to 210 kN and the torque value was from 405 to 556 Nㆍm. The range of torque coefficient at indoor conditions was analyzed from 0.126 to 0.158 while tensions were indicated from 179 to 192 kN. The torque coefficient at site conditions was ranged from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient, tension subjected temperature can be taken by statistic regressive analysis. The variable of torque coefficient under the indoor conditions is 0.13%/℃ while it reaches 2.73%/℃ at actual site conditions. When the indoor trends and site conditions is combined, the modified variable of torque coefficient can be expected as 0.2% /℃. and the modified variable of tension can be determined as 0.18%/℃.
        4,000원
        64.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        UHPC(Ultra High Performance Concrete) is used widely with its remarkable performance, such as strength, ductility and durability. Since the fibers in the UHPC can control the tensile crack, the punching shear capacity of UHPC is higher than that of the conventional concrete. In this paper, seven slabs with different thickness and fiber volume ratio were tested. The ultimate punching shear strength was increased with the fiber volume ratio up to 1%. The shear capacity of specimens with the fiber content 1% and 1.5% do not have big differences. The thicker slab has higher punching shear strength and lower deformation capacity. The critical sections of punching shear failure were similar regardless of the fiber volume ratio, but it were larger in thicker slab.
        4,000원
        65.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.
        4,000원
        66.
        2015.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        High temperature plasma coating technology has been applied to recover damaged aluminum dies from wear by spraying pure aluminum and alumina powder. However, the coated mixed powder layer composed of aluminum and alumina often undergoes a detachment from the substrate, making the coated substrate die unable to maintain its expected life span. In this study, in order to increase the bonding strength between the substrate and the coating layer, a pure aluminum layer was applied as an intermediate bond layer. In order to prepare the specimen with variable bond coating conditions, the bond coat layers with a various gun speed from 10 cm/sec to 30 cm/sec were prepared with coating cycle variations ranging from three to nine cycles. The specimen with a bond coat layer coated with a gun speed of 20 cm/sec and three coating cycles exhibited ~13MPa of adhesion strength, while the specimen without a bond coat layer showed ~6 MPa of adhesion strength. The adhesion strength with a variation of bond coat layer thickness is discussed in terms of coating parameters.
        4,000원
        67.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the cold rolled DP590 FSW joints were obtained by the position control type of the FSW machine and examined. The FSW weldability was investigated using the Si3N4 tool specially made by Cold Isostatic Press (CIP). Defect-free joints were formed at 180-300 mm/min at 800 rpm. However, a groove-like defect was observed along the joint line of the advancing side due to the insufficient material flow. In addition, the life of the Si3N4 tool was compared to that of the polycrystalline cubic boron nitride (PCBN) tool for the durability. The SI3N4 tool that was broken in which tool reached a length of 5 m and around half of the performance level of the PCBN tool.
        4,000원
        68.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we applied a membrane distillation process to investigate a feasibility of treating a wastewater with high concentration of organic matters including nitrogen and phosphorus. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of 0.22 μm and porosity of 75%. The installation was direct contact type where the temperature difference between a feed and permeate side was controlled to have a range from 20 to 60°C. We observed a flux variation and a concentration changes of COD, PO4 3--P, NH4 + -N and conductivity of feed side as well as permeate side with various temperature differences (20 to 60°C), cross flow velocities (0.09 to 0.27 m/s) through the module, and pH (6.6 to 12.0) of the feed that has the initial concentration of COD about 1,000 mg/L, total nitrogen 390 mg/L, total phosphorus 10 mg/L, conductivity of 7,000 μs/cm. The results showed that the average flux was ranged from 4 to 40 L/m2/hr which was almost similar with the flux of NaCl and deionized water used as a feed solution. The lowest flux was obtained at the operating condition with the temperature difference of 20°C and cross flow velocity of 0.09 m/s while the highest one was measured with 60°C and 0.27 m/s. Above 99% of COD and PO4 3- -P in the feed could be rejected regardless of an operating condition. However, the removal rate of ammonium nitrogen was varied from 64 to 99% depending on the pH of feed solution.
        4,000원
        69.
        2015.04 구독 인증기관·개인회원 무료
        The clamping of torque shear high strength bolt is induced when the pin-tail is broken. Sometimes the clamping forces on slip critical connections do not meet the required tension due to torque coefficient dependent on conditions such as outdoor temperature, moisture and dust. From this study, the clamping forces of torque shear bolts at indoor conditions were compared with actual data investigated from 24 construction sites last five years. Similarly to foreign literature results, torque shear bolts showed that torque coefficients were fluctuated greatly by temperature conditions. The range of torque coefficient at indoor conditions was analyzed from 0.126 to 0.158 while tensions were indicated from 179 to 192 Nㆍm. Instead, the range of torque coefficient at site conditions was analyzed from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient subjected temperature can be traced via statistic regressive analysis. In case of indoor conditions, it was showed that the variable of torque coefficient was 0.13% per 1℃, while the variable at actual site conditions reached 2.73% per 1℃.
        70.
        2015.04 구독 인증기관·개인회원 무료
        This study is a part of high strength lightweight aggregate concrete researches using lightweight aggregates and the purpose of this study is to find out the basic physical characteristics and tension cracking fracture characteristics of lightweight concrete. Crack Mouth Opening Displacement is measured through three point flexure experiment about embellish notch beam. Load-CMOD characteristics are examined through rules of countries, characteristics of lightweight concrete and tension cracking fracture experiments. The degree of tensile characteristic alteration according to size changes of specimen and the characteristics about crack surface are analyzed. The changes of softening curve are analyzed and fracture energy is drawn through inverse analysis by the obtained Load-CMOD curve. To decide fracture energy and analysis parametric, inverse analysis is conducted and Ant Colony Method is conducted for optimization and then a way to find out optimal parameterization fracture energy is suggested.
        71.
        2014.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The present study deals with the effects of tempering treatment on the microstructure and mechanical properties of Cu-bearing high-strength steels. Three kinds of steel specimens with different levels of Cu content were fabricated by controlled rolling and accelerated cooling, ; some of these steel specimen were tempered at temperatures ranging from 350˚C to 650˚C for 30 min. Hardness, tensile, and Charpy impact tests were conducted in order to investigate the relationship of microstructure and mechanical properties. The hardness of the Cu-added specimens is much higher than that of Cu-free specimen, presumably due to the enhanced solid solution hardening and precipitation hardening, result from the formation of very-fine Cu precipitates. Tensile test results indicated that the yield strength increased and then slightly decreased, while the tensile strength gradually decreased with increasing tempering temperature. On the other hand, the energy absorbed at room and lower temperatures remarkably increased after tempering at 350˚C; and after this, the energy absorbed then did not change much. Suitable tempering treatment remarkably improved both the strength and the impact toughness. In the 1.5 Cu steel specimen tempered at 550˚C, the yield strength reached 1.2 GPa and the absorbed energy at -20˚C showed a level above 200 J, which was the best combination of high strength and good toughness.
        4,000원
        72.
        2014.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Effects of Cu and B on effective grain size and low-temperature toughness of thermo-mechanically processed high-strength bainitic steels were investigated in this study. The microstructure of the steel specimens was analyzed using optical, scanning, and transmission electron microscopy; their effective grain size was also characterized by electron back-scattered diffraction. To evaluate the strength and low-temperature toughness, tensile and Charpy impact tests were carried out. The specimens were composed of various low-temperature transformation products such as granular bainite (GB), degenerated upper bainite (DUB), lower bainite (LB), and lath marteniste (LM), dependent on the addition of Cu and B. The addition of Cu slightly increased the yield and tensile strength, but substantially deteriorated the low-temperature toughness because of the higher volume fraction of DUB with a large effective grain size. The specimen containing both Cu and B had the highest strength, but showed worse low-temperature toughness of higher ductile-brittle transition temperature (DBTT) and lower absorbed energy because it mostly consisted of LB and LM. In the B-added specimen, on the other hand, it was possible to obtain the best combination of high strength and good low-temperature toughness by decreasing the overall effective grain size via the appropriate formation of different low-temperature transformation products containing GB, DUB, and LB/LM.
        4,000원
        73.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on the environmental factors and temperature variables despite the break of the pin tail.This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition. And the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter.
        4,000원
        74.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to increase applicability of high strength steel, HSA800 to the structure. Selected study of structure is to consider high strength steel, and following parts, 1) Tensile member with no consider of buckling, 2) Truss existing both tension and compression members with small slenderness ratio. This studied structure is included tension column hang on to the upper bridge truss. The structure element quantity with apply HSA800 instead of SM570 is reduced about 38.9% of tension column and 29.7% of bridge truss. In addition, the number of element's division is reduced about two sections due to reduction of self weight that the crane is able to lift up. This improves to reduce erection sequence and construction period which can save about a month. All connections are reviewed as welding and bolt. Also, the cost of welding is reduced about 41.3% due to apply HSA800. In conclusion, applying HSA800 to the hanging structure aggressively can secure economic and constructability.
        4,000원
        75.
        2014.04 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        TiC-21mol% Mo solid solution (δ-phase) and TiC-99 mol% Mo solid solution (β-phase), and TiC-(80~90)mol%Mo hypo-eutectic composite were deformed by compression in a temperature range from room to 2300 K and in a strain raterange from 4.9×10−5 to 6.9×10−3/s. The deformation behaviors of the composites were analyzed from the strengths of theδ- and β-phases. It was found that the high strength of the eutectic composite is due primarily to solution hardening of TiCby Mo, and that the δ-phase undergoes an appreciable plastic deformation at and above 1420 K even at 0.2% plastic strainof the composite. The yield strength of the three kinds of phase up to 1420 K is quantitatively explained by the rule of mixture,where internal stresses introduced by plastic deformation are taken into account. Above 1420 K, however, the calculated yieldstrength was considerably larger than the measured strength. The yield stress of β-phase was much larger than that of pure TiC.A good linear relationship was held between the yield stress and the plastic strain rate in a double-logarithmic plot. Thedeformation behavior in δ-phase was different among the three temperature ranges tested, i.e., low, intermediate and high. Atan intermediate temperature, no yield drop occurred, and from the beginning the work hardening level was high. At the testedtemperature, a good linear relationship was held in the double logarithmic plot of the yield stress against the plastic strain rate.The strain rate dependence of the yield stress was very weak up to 1273 K in the hypo-eutectic composite, but it becamestronger as the temperature rose.
        4,000원
        76.
        2014.04 구독 인증기관·개인회원 무료
        Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition.
        77.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        강도 한계상태 설계에서는 균열이 일어난 이후 철근콘크리트 부재의 인장영역에서 철근이 모든 인장력을 부담하는 것으로 가정한다. 그러나 균열 사이의 콘크리트가 실제 콘크리트 부재에서는 특히 사용하중 수준에서의 어느 정도의 인장 응력을 견디는데, 일조 하는 것으로 보고 있다. 이러한 효과를 Tension stiffening 효과라 한다. 본 연구에서는 Tension stiffening 모델과 고강도 철근 콘크리트 보의 휨 실험결과의 비교를 통해 해석모델의 유효성을 평가 하고자 한다. 이를 통해 선정 된 6가지의 Tension stiffening 모델과 실험에 의한 모멘트-곡률, 하중-처짐등을 관계를 평가하였다. 실험결과 설계기준에서는 ACI 318이 Tension stiffening 모델에서는 Owen & Damjanic이 실험 값과 가장 적은 오차율을 보이며 높은 신뢰도를 보였다.
        4,000원
        78.
        2013.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This study investigated the continuous cooling transformation, microstructure, and mechanical properties of highstrength low-alloy steels containing B and Cu. Continuous cooling transformation diagrams under non-deformed and deformed conditions were constructed by means of dilatometry, metallographic methods, and hardness data. Based on the continuous cooling transformation behaviors, six kinds of steel specimens with different B and Cu contents were fabricated by a thermomechanical control process comprising controlled rolling and accelerated cooling. Then, tensile and Charpy impact tests were conducted to examine the correlation of the microstructure with mechanical properties. Deformation in the austenite region promoted the formation of quasi-polygonal ferrite and granular bainite with a significant increase in transformation start temperatures. The mechanical test results indicate that the B-added steel specimens had higher strength and lower upper-shelf energy than the B-free steel specimens without deterioration in low-temperature toughness because their microstructures were mostly composed of lower bainite and lath martensite with a small amount of degenerate upper bainite. On the other hand, the increase of Cu content from 0.5 wt.% to 1.5 wt.% noticeably increased yield and tensile strengths by 100 MPa without loss of ductility, which may be attributed to the enhanced solid solution hardening and precipitation hardening resulting from veryfine Cu precipitates formed during accelerated cooling.
        4,000원
        79.
        2013.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Over the past few decades, high-nitrogen austenitic steels have steadily received greater attention since they provide a unique combination of high strength and ductility, good corrosion resistance, and non-magnetic properties. Recently, highnitrogen 18Mn-18Cr austenitic steels with enhanced strength have been developed and widely used for generator retaining rings in order to prevent the copper wiring from being displaced by the centrifugal forces occurring during high-speed rotation. The high-nitrogen austenitic steels for generator retaining ring should be expanded at room temperature and then stress relief annealed at around 400˚C to achieve the required mechanical properties. In this study, four kinds of high-nitrogen 18Mn-18Cr austenitic steels with different nitrogen content were fabricated by using a pressurized vacuum induction melting furnace, and then the effects of nitrogen content, cold working, and stress relieving on tensile properties were investigated. The yield and tensile strengths increased proportionally with increasing nitrogen content and cold working, and they further increased after stress relieving treatment. Based on these results, a semi-empirical equation was proposed to predict the tensile strength of highnitrogen 18Mn-18Cr austenitic steels for generator retaining rings. It will be a useful for the effective fabrication of high-nitrogen 18Mn-18Cr austenitic steels for generator retaining rings with the required tensile properties.
        4,000원
        80.
        2013.09 구독 인증기관 무료, 개인회원 유료
        Ultra high performance concrete which has recently been studied was developed to complement the brittle behaviour and dynamic uppermost limit of high strength concrete. Fiber reinforced concrete which mixed steel fiber is receiving attention as an alternative about this and is being developed to complement the disadvantages of high strength concrete including lower toughness coefficients and crack resistance and spalling in fires. Review about fiber reinforced ultra high strength concrete that this study tries to treat includes reduction of self shrinkage generated by high cement content per unit volume of concrete, evaluation of compression and tension strength to lower internal and external spalling resistance and fragility factors of member of framework, and flow characteristics of concrete which doesn't harden according to steel fiber amounts and used materials. As the result, the more fiber reinforcement increases, the more compression and tensile strength increase and deformation control of cement matrix and improvement of energy absorption ability showed the great effect in shrinkage reduction.
        4,000원