검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 285

        81.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For the asset management of a water pipe network, it would be necessary to understand the extent of the maintenance cost required for the water pipe network for the future. This study would develop a method to draw the optimum cost required for the maintenance of the water pipe network in waterworks facilities to maintain the aim revenue water ratio and to achieve the target revenue water ratio, considering the water service providers’ waterworks condition and revenue water ratio comprehensively. This study conducted a survey with 96 water service providers as of the early 2015 and developed models to estimate the optimum maintenance cost of the water pipe network, considering the characteristics of the water service providers. Since the correlation coefficient of all the developed models was higher than 0.95, it turned out that it had significant reliability, which was statistically significant. As a result of applying the developed models to the actual water service providers, it was drawn that increasing revenue water ratio to more than a certain level can reduce the maintenance cost of the water pipe network by a great deal. In other words, it is judged that it would be the most efficient to secure the reliability of waterworks management by increasing the short-term revenue water ratio to more than a certain level and gradually increase the revenue water ratio from the long-term perspective. It is expected that the proposed methodology proposed in this study and the results of the study will be used as a basic research for planning the maintenance of water pipe network or establishing a plan for waterworks facilities asset management.
        4,300원
        82.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to propose the sewer defect scoring, and grading protocols for sewer condition assessment. For this, sewer defect scoring methods were comparatively analyzed and reviewed for four international condition assessment protocols, which are established based on WRc manual. As a result, we proposed a new protocol for sewer condition assessment, in which characteristics of sewer pipes are considered by segment. In reference to the PIM-3, the extent of ground subsidence was adopted to be of importance, and renewal scores increased in accordance with weighting of defects causing structural backfill materials. Also, defect grades of ‘Hole’ were extended to 5 levels of the grading, and ‘Surface Damage’ was excluded in defect assessment. The addition of ‘Buckling’ resulted in reduction of weights in ‘Surface Damage’ and ‘Lining Defects’.
        4,000원
        83.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most of existing buried pipes are composed of reinforced concrete. Reinforced concrete pipes have many problems such as aging, corrosion, leaking, etc. The polyethylene (PE) pipes have advantages to solve these problems. The plastic pipes buried underground are classified into a flexible pipe. National standard that has limited the long-term vertical deformation of the pipe to 5% for flexible pipes including PE pipe. This study presents a prediction for the long-term behavior of the polyethylene pipe based on ASTM D 5365. This prediction method is presented to estimate by using the statistical method from the initial deflection measurement data. We predict the behavior of long-term performance on the double-wall pipe and multi-wall pipe. As a result, it was found that the PE pipe will be sound enough more than 50 years if the compaction of soil around the pipe is more than 95% of the standard soil compaction density.
        4,000원
        84.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        There is a growing concern on the improvement of water distribution pipeline for multi-regional water supply system in Korea along with its aging infrastructure. Rehabilitation of large diameter pipeline is more efficient in cost and time compared to replacement with trenching. The procedure for rehabilitation are diagnosis, cleaning, spraying coating material, and final inspection. The internal state of pipeline was carefully diagnosed and got C grade, which required rehabilitation. We found that 17,274,787,000 Korean won could be saved after pipe surface coating because of increased C coefficient of Hazen-Williams equation. Optimal coating material was D polyurea. We also found optimal distance between spraying nozzle and pipe wall to be 70 - 80 cm, which were critical factors for coating quality. This study also illustrated the time for spray drying to be more than 30 min. These results could be used in the quality control process during rehabilitation of aged pipelines.
        4,300원
        85.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Sewer condition assessment involves the determination of defective points and status of aged sewers by a CCTV inspection according to the standard manual. Therefore, it is important to establish a reliable and effective standard manual for identifying the sewer defect. In this study, analytic reviews of the CCTV inspection manuals of the UK, New Zealand, Canada and South Korea were performed in order to compare the defect codes and the protocols of condition assessment. Through this, we also established the standardized method for defect code and revised the calculation method of assigning the condition grade. Analyses of the types and frequencies of sewer defects that obtained by CCTV inspection of 7000 case results, showed that the joint defect and lateral defect were the most frequent defects that occurred in Korea. Some defect codes are found to be modified because those did not occur at all. This study includes a proposed new sewer defect codes based on sewer characteristics.
        4,300원
        86.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 세굴된 해저 파이프 주위 중력류의 유동 해석을 수행하였다. 결과 비교를 위해 세굴이 아닌 평평한 해저면 위에 틈새 거리를 두고 설치된 해저 파이프 문제를 함께 고려하였다. 여기서 세굴의 깊이와 틈새 거리는 동일하며, 평평한 해저면 위에 설치된 파이프 문제는 일반적으로 실제 세굴효과를 이상적으로 구현하기 위해 주로 고려된다. 중력류와 해저 파이프 상호작용에 대한 유동특성의 이해를 위해 농도 및 와도장, 압력장 그리고 양항력 계수 등, 다양한 물리량들을 비교 및 분석 하였다. 결과적으로 세굴과 평평한 해저면 위에 설치된 해저 파이프 주위 유동특성이 달라짐을 관찰하였다, 특히 세굴의 위 파이프의 경우 구조물 상부에서 발달된 음의 와만 하류로 나아가게 되지만 평탄면 위 파이프는 이열 와구조 형태를 가지는 것을 확인하였다. 따라서 중력류에 놓인 해저 파이프의 안전 설계를 위해서는 무엇보다 실제 세굴조건을 고려하는 것이 중요 할 것으로 판단된다.
        4,000원
        87.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipes are widely used in the water supply pipeline system. However, they have some disadvantages such as reduced durability due to material degradation, defects in connections, breakage of pipelines, and difficulties in continuous maintenance. To mitigate such problems, recently, research on durable and outstanding corrosion resistant glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, it should review the structural behavior and interaction between buried pipe and its surrounding soil because pipe will support the load with the surrounding soil together at the same time. To apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.
        4,000원
        89.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, factors analysis is performed for reducing friction in elevation motion of a large television stand over 50-inch. The first is a pipe type cross-section control for accurate position control of the piston rod. Here it was compared with the pipe type and labyrinth type orifice cross-section. The second study is for specification decision and volume compensation experiment as an apparatus for compensating of the volume of the cylinder is compressed as the volume of piston rod. Consequently, in the orifice cross section study between pipe type and labyrinth type through CAE and experimental consideration, cross section of labyrinth type orifice is preferred for reducing of friction. The result of total consideration in stability problem and performance of volume compensation for specification decision and volume compensation experiment is determined the final speculation of hollow rod φ8×φ4 and riveting system.
        4,000원
        90.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, factors analysis is performed for reducing friction in elevation motion of a large television stand over 50-inch. The first is a pipe type cross-section control for accurate position control of the piston rod. Here, it was compared with the pipe type and labyrinth type orifice cross-section. The second study attempted to reduce the frictional force the gas seal lip technology. As the result of the first study, in the orifice cross section study between pipe type and labyrinth type through CAE and experimental consideration, cross section of labyrinth type orifice is preferred for reducing of friction. As the result of the second study, in the gas seal lip technology, the outer-inner diameter of φ20×φ8 in the test result of hollow rod is revealed more proper if the weight of 50 inch television assumed as 30kgf.
        4,000원
        91.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recent frequent occurrence of urban sinkhole brings a need for the periodic inspection of sewer pipelines. Sewer inspection using a CCTV device needs a lot of time and efforts. Many of previous studies which have focused to reduce the laborious tasks are mainly interested in the developments of image processing S/W and inspection H/W. Nevertheless, there has been no attempt to find meaningful information from the existing CCTV images stored by the sewer maintenance manager. In this paper, we carried out a study about the construction of unfolding image of sewer video image. In general, the analysis results show that the image development is judged to have been well represented. It is expected to be a reference to the basic research of panoramic image.
        4,000원
        92.
        2016.04 구독 인증기관·개인회원 무료
        In the water supply pipeline system, pipes made by cast iron, PE, PVC are generally used. However, the structural performance of these materials can be declined when used for long periodsof time because of corrosion, creep, deterioration of the material, etc. while glass fiber reinforced polymer plastics (GFRP) have many advantages such as light-weight, corrosion resistance, smooth surface, etc. For these reasons, GFRP pipes are good for construction when it is buried underground and are increasing trend in applying the water supply pipeline system. Therefore, more optimized structural design methodology should be developed. In this paper, we confirm pipe stiffness (PS) of GFRP pipe in which the pipe stiffness indicates the load-bearing performance. We compared data of parallel-plate loading test and theoretically predicted PS by the classical elasticity theory and the finite element method (FEM).
        93.
        2016.04 구독 인증기관·개인회원 무료
        In the water supply pipeline system polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipe are mostly used. However, they have some problems such as reduced durability due to material degradation, defects in connections, the pipelines breakage, and lack of continuous maintenance. Recently, research on durable and outstanding corrosion resistance glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, pipe will support the load with the surrounding soil. In this paper, to apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.
        94.
        2016.04 구독 인증기관·개인회원 무료
        Pipe line for the water supply and/or drainage is one of the most important life lines which is usually suffered from the damage due to exterior load induced deformation and due to the lack of support resistance provided by the surrounding soil. GFRP (Glass Fiber Reinforced Polymer Plastic) pipes are generally thinner, lighter, but stronger than the existing concrete or steel pipes, and it is excellent in stiffness/strength per unit weight. In this study, we present the result of field test for buried RPMP (Reinforced Polymer Mortar Pipe) and RTRP (Reinforced Thermosetting Resin Pipe) pipes with 2,400mm diameter. The vertical and horizontal ring deflections are measured for 387 days. The ring deflection of RPMP and RTRP measured by the field test is compared with the ring deflection limitation (5%) according to ASTM D 2412.
        95.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the structural characteristics of a lightweight soundproof tunnel to reduce the dead load imposed on the bridge are investigated. Subsequently, the design procedure of soundproof tunnel structures is reviewed and a design practice for the lightweight soundproof tunnel is carried out according to the reviewed procedure. Next, design compatibility for the lightweight soundproof tunnel is verified through a detailed finite element analysis. The result for evaluation of design compatibility shows that the lightweight soundproof tunnel has structural safety in structural members, welding zones and foundation parts. It is also confirmed that serviceability and buckling safety is excellent.
        4,000원
        96.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results m
        4,000원
        97.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박 및 플랜트의 배관은 제작부터 설치까지 일련의 과정을 모두 현장에서 하는 것이 아닌, 외부의 공장 또는 숍으로부터 배관의 제일 작은 요소인 스풀 배관을 제작하고, 이를 작업현장 또는 현장 근처의 공장에서 모듈화 또는 가설치 작업 및 현장에서 직접 설치작업을 통해 제작이 된다. 이 과정에서 스풀은 3D CAD를 기반으로 하는 것이 아닌 2D 도면을 기반으로 하기 때문에, 작업공간을 고려하지 못할 수 있다. 이러한 이유로 실제 설치작업 시 작업공간의 방해로 인한 공기의 지연을 발생 시킬 수 있다. 본 논문은 이러한 스풀 배관의 설치 시 또는 운용 및 유지보수 시에 생길 수 있는 외부 구조물과의 스풀 위치에 관하여, 스풀 위치가 외부 구조물로부터 방해를 받지 않도록 하기 위한 방법으로 유전 알고리즘을 적용하여 스풀 위치를 결정하는 방법에 대해 제시하고자 한다.
        4,000원
        98.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This is to develop a micro water turbine which makes some power from just a fluid velocity in the water pipe. While power is produced from impulsive force which generated by a high head in the case of existing water turbine, this is to produce a power from rotating force of helical turbine which rotated by fluid velocity in the water pipe. Some results of analysis fluid pattern at turbine blade for design shows that bubble is generated from turbulence surrounding blade and pulsatory motion generated as fluid being blocked and opened by blade due to turbine structure. This two phenomena cause to lower power production efficiency and shorten turbine durability. So this is studied to minimize bubble generation and pulsation for optimizing design of turbine blade. Therefore it is determined that the number of blade is three, geometric form of blade is NACA 4420 and angle of blade is 30 degree. An experiment equipment of water turbine is manufactured on the base of these factors(NACA 4420, angle 30。). It is obtained that power production of turbine increases in proportion to velocity which is changed from 1.7 m/sec to 3.5 m/sec. When fluid velocity is 1.7m/sec the power production of turbine is 355W. Power production increase continuously as increasing the fluid velocity and power is 2kW on 3m/sec of fluid velocity.
        4,000원
        99.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, Hazen-Williams C value of pipes in wide waterworks system was estimated and statistically analyzed. Hazen-Williams C value of water pipe was predicted after 20 years of service period. From the results, it was found that C value of water pipe for treated water maintained higher value of 110 after 20 years of installation. Furthermore, it was found that velocity coefficients of steel pipe for less than and more than 20 years of installation were 117.7 and 109.3, respectively. C value of ductile iron pipe for less than and more than 20 years of installation were 118.1 and 114.2, respectively. In this study, it was also found that small value of C is used in the design of water pipe system. Therefore, excessively bigger size of pipe can be determined in the design of water pipe system. From the results of present study, optimum value of C can be used to avoid the oversized design of water pipe system.
        4,000원
        100.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.
        4,000원
        1 2 3 4 5