검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 47

        1.
        2023.11 구독 인증기관·개인회원 무료
        The first commercial operation of Kori-1, which commenced in April 1978, was permanently shut down in June 2017, with plans for immediate dismantling. The decommissioning process of nuclear power plants generates a substantial amount of radioactive waste and poses significant radiation exposure risks to workers. Radioactivity is widely distributed throughout the primary coolant system of the reactor, including the reactor pressure vessel (RPV), steam generator (SG), and pressurizer. In particular, the SG has a considerable size and complex geometry, weighing approximately 326 tons and having a volume of 400 m3. The SG tubes are known to contain high levels of radioactivity, leading to significant radiation exposure to workers during the dismantling process. Therefore, this study aims to evaluate the workers’ radiation exposure during the cutting of SG tubes, which account for approximately 95% of the total radiation dose in the SG. Firstly, the CRUDTRAN code, developed to predict the behavior of soluble and particulate corrosion products in a PWR primary coolant system, is used to estimate the radioactive inventory in the SG tubes. Based on decontamination factors (DF) obtained in the SG tubes through overseas experience, the expected reduction in radioactivity during the Kori-1 reactor’s full-system decontamination (FSD) process is considered in the CRUDTRAN results. These results are then processed to estimate the radioactivity in both the straight and bent sections of the tubes. Subsequently, these radioactivity values are used as inputs for the MicroShield code to calculate the worker radiation exposure during the cutting of both straight and bent sections of the tubes. The cutting process assumes that each SG tube section is cut in a separate, shielded area, and the radiation exposure is assessed, taking into account factors such as cutting equipment, cutting length, working hours, and working distance. This study evaluates the worker radiation exposure during the cutting of SG tubes, which are expected to have a significantly high radioactivity due to chalk river unidentified deposit (CRUD). This assessment also considers the reduction in radioactivity within the steam generator tubes resulting from the FSD process. Consequently, it enables an examination of how worker radiation exposure varies based on the extent of FSD. This study may provide valuable insights for determining the scope and extent of the FSD process and the development of shielding methods during the dismantling of SG tubes in the future.
        2.
        2022.10 구독 인증기관·개인회원 무료
        In accordance with the notification of the Nuclear Safety and Security Commission (NSSC), environmental impact assessments around nuclear power plants are conducted annually and the results are disclosed to the public. The effects of direct radiation exposure from nuclear power plants as well as liquid effluents and gaseous effluents are taken into consideration in the evaluation of dose calculation for residents. In the United States, regulatory guidelines on direct radiation exposure are described in Reg. Guide 4.1, and the effects of direct radiation are evaluated through regulatory guidelines in Korea. We are going to review optimal evaluation method by reviewing the direct radiation exposure evaluation method currently being conducted in domestic nuclear power plants and the direct radiation exposure evaluation method in overseas nuclear power plants such as in the United States.
        3.
        2022.10 구독 인증기관·개인회원 무료
        Since radon was detected in mattresses of famous bed furniture brands in 2018, the nuclear safety and security commission (NSSC) announced the radiation safety management act in April 2021 to protect the public health and environment. This act stipulates the safety management of radiation that can be encountered in the natural environment such as the notification of radioactivity concentration of source materials, process by-products, the installation and operation of radioactive monitors. In this study, a model was established to predict radioactive exposure dose from radioactive materials such as radon and uranium detected in consumer products such as bed mattresses, pillows, shower, bracelets and masks in order to identify major radioactive substances that largely affect the exposure dose. A period of seven years from 2014 to 2020 was investigated for the source materials and exposure doses of consumer products containing naturally occurring radioactive materials (NORMs). We analyzed these using machine learning models such as classification and regression tree (CART), Random Forest and TreeNet. Index development and verification were performed to evaluate the predictive performance of the models. Overall, predictive performance was highest when Random Forest or TreeNet was used for each consumer product. Thoron had a great influence on the internal exposure dose of bedding, clothing and mats. Uranium had a great influence on the internal exposure dose of other consumer products except whetstones. When the number of data is very small or the missing value rate is high, it is difficult to expect accurate predictive performance even with machine learning techniques. If we significantly reduce the missing value rate of data or use the limit of detection value instead of missing values, we can build a model with more accurate predictive performance.
        4.
        2022.05 구독 인증기관·개인회원 무료
        This study is for evaluation and optimization of workers’ radiation exposure for dismantling Reactor Vessel (RV) at Kori unit 1 in connection with its decommissioning process for the purpose of establishing Radiation Safety Management Plan. This is because the safety of workers in a radiation environment is an important issue. The basis of radiological conditions of this evaluation is supposed to be those of 10 years after the permanent shutdown of Kori unit 1 when dismantling work of Reactor Vessel would suppose to be started. Dose rates of work areas were evaluated on the basis of spatial dose rate derived from activation level calculated by MCNP (Monte Carlo N-Particle Transport) and ORIGEN-S code. RV are radiated by neutrons during operation, creating an environment in which it is difficult for operators to access and work. Therefore, the RV must be dismantled remotely. However, due to work such as installing devices or dismantling surrounding structures, it is not possible to completely block the access of workers. Accordingly, the exposure of workers to the RV dismantling process should be assessed and safety management carried out. The dismantling process of Kori unit 1 RV was developed based on in-situ execution in atmospheric environment using the oxigen-propane cutting technology as the following steps of Preparation, Dismantling of Peripheral Structures, Dismantling of RV and Finishing Work. For evaluation of exposure of RV dismantling work, those processes of each steps are correlated with spatial dose rates of each work areas where the jobs being done. Results of the evaluation show that workers’ collective dose for RV dismantling work would be in the range of 536–778 man- mSv. The most critical process would be dismantling of upper connecting parts of RV with 170–256 manmSv while among the working groups, the expert group performing dismantling of ICI (In-core instrumentation) nozzles and handling & packaging of cut-off pieces is evaluated as the most significantly affected group with 37.5–39.4 man- mSv. Based on the evaluation, improvement plan for better working conditions of the most critical process and the most affected workers in terms of radiation safety were suggested.
        7.
        2021.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In the dismantling process of a reactor coolant system (RCS) piping, a radiation protection plan should be established to minimize the radiation exposure doses of dismantling workers. Hence, it is necessary to estimate the individual effective dose in the RCS piping dismantling process when decommissioning a nuclear power plant. In this study, the radiation exposure doses of the dismantling workers at different positions was estimated using the MicroShield dose assessment program based on the NUREG/CR-1595 report. The individual effective dose, which is the sum of the effective dose to each tissue considering the working time, was used to estimate the radiation exposure dose. The estimations of the simulation results for all RCS piping dismantling tasks satisfied the dose limits prescribed by the ICRP-60 report. In dismantling the RCS piping of the Kori-1 or Wolsong-1 units in South Korea, the estimation and reduction method for the radiation exposure dose, and the simulated results of this study can be used to implement the radiation safety for optimal dismantling by providing information on the radiation exposure doses of the dismantling workers.
        4,200원
        14.
        2020.08 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        한국원자력환경공단은 처분시설 내 1단계 인수·저장구역의 인수검사 공간 및 드럼 취급 공간 부족에 대한 문제를 해결하기 위하여 방폐물검사건물을 건설하여 저장·처리능력을 확충할 예정이다. 본 연구에서는 MCNP 코드를 이용하여 방폐물검사 건물 내 저장구역에서 취급하는 해체 방사성폐기물 대상 신형처분용기를 대상으로 작업종사자의 피폭선량을 평가하였다. 평가결과, 시설 내 저장 가능한 최대 용기 개수(304개)와 방사선작업에 대한 연간 예상 작업시간(약 306시간)에 대하여 연간 집단선량은 총 84.8 man-mSv로 계산되었다. 시설 내 총 304개의 신형처분용기(소형/중형 타입)가 저장 완료된 시점에서 인수검사, 처분검사를 위한 작업종사자의 투입인력은 총 25명, 작업종사자 당 예상피폭선량은 연평균 3.39 mSv로 산출 되었다. 소형용기 취급 시 작업종사자의 고방사선량 작업에 따른 작업효율과 방사선적 안전성 확보를 위해서는 콘크리트 라이너의 두께를 증가시키는 추가적인 차폐가 필요할 것으로 평가되었다. 향후 본 연구를 바탕으로 실측기반의 해체폐기 물의 선원항과 특성을 활용하여 방사선작업 당 작업시간 및 투입인력을 산출함으로써 작업종사자의 최적의 방사선작업조건을 도출할 수 있을 것으로 사료된다.
        4,000원
        18.
        2018.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        대한민국 첫 상업원전인 고리1호기는 40년간의 성공적인 운전을 끝내고 2017년 6월 18일 영구정지 되었다. 고리1호기는 본격적인 해체에 앞서 터빈건물에 폐기물처리시설 건설을 계획하고 있다. 각종 방사성폐기물은 폐기물처리시설에서 제염, 해체, 절단, 용융되어 자체처분 되거나 방사성폐기물 처분장으로 보내 진다. 해체폐기물 중 대형금속방사성폐기물은 주로 1차 계통측 기기들로 높은 방사능을 띄고 있어 해체활동 중 작업자의 피폭관리가 필요하다. 본 논문에서는 대형금속방사성폐기물 중 크기가 가장 크고 형상이 복잡한 증기발생기를 선정하여 RESRAD-RECYCLE 코드를 이용하여 작업자 피폭선량을 평가하고 저감화 방안을 수립 하고자 한다.
        4,200원
        19.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers’ health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.
        4,000원
        20.
        2011.11 구독 인증기관 무료, 개인회원 유료
        The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.
        4,000원
        1 2 3