        In this analysis, the analytical model was verified through the normal mode analysis of the piston for the 2.9 liter IDI (indirect injection) engine. Heat transfer analysis was carried out by selecting two cases of applied temperature using the validated model. The first case was a condition of 350℃ on the piston upper surface and 100℃ on the piston body and inner wall. In the second case, the conditions were set to give a temperature of 400℃ on the upper surface of the piston and 100℃ on the piston body and the inner wall. In addition, the temperature distribution due to heat transfer was obtained for the pistons with boundary conditions of two cases, and then the thermal stress distribution due to thermal expansion was obtained using the input. Using this analysis result, the thermal stress caused by thermal expansion due to the thermal conduction of the piston is examined and used as the basic data for design.
        4,000원
        2.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. 200℃, 400℃ and 600℃ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. In addition, thermal conduction test was tested in order to find out concrete insulation. According to this test, when concrete was tested by fire resistance, it using the circulation aggregate was same resulted by concrete using the natural aggregate. also, recycle powder was not effecting insulation performance. but it is fit to standard on concrete insulation of building law.
        4,000원
        3.
        2004.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We discuss diffusion of particles in turbulent flows. In hydrodynamic turbulence, it is well known that distance between two particles imbedded in a turbulent flow exhibits a random walk behavior. The corresponding diffusion coefficient is ~ vinjlturb, where vinj is the amplitude of the turbulent velocity and lturb is the scale of the turbulent motions. It Is not clear whether or not we can use a similar expression for magnetohydrodynamic turbulence. However, numerical simulations show that mixing motions perpendicular to the local magnetic field are, up to high degree, hydrodynamical. This suggests that turbulent heat transport in magnetized turbulent fluid should be similar to that in non-magnetized one, which should have a diffusion coefficient ~ vinjlturb. We review numerical simulations that support this conclusion. The application of this idea to thermal conductivity in clusters of galaxies shows that this mechanism may dominate the diffusion of heat and may be efficient enough to prevent cooling flow formation when turbulence is vigorous.
        4,000원
        4.
        1999.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We present the results of one-dimensional numerical simulations of SNR evolution in the in­homogeneous medium considering the effects of the evaporation of the cloud and the thermal conduction. We have included the effects of changing evaporation rate as a function of cloud size and the ambient temperature so that the clouds could be evaporated completely before they reach the center of the SNR. The heat conduction markedly changes the density distribution in the remnant interior. To explain the observed morphologies of the centrally peaked X-ray SNRs(for example W44), the maximal thermal conduction is required. However, this is unlikely due to the magnetic field and the turbulent motion. The effects of the evaporation of the cloud and the thermal conduction described here may explain the class of remnants observed to have centrally peaked X-ray emmision.
        4,000원
        5.
        2014.04 서비스 종료(열람 제한)
        The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research structural insulation concrete what improved insulation performance using Micro Form Admixture.