We are confronted with the serious EMI(electromagnetic interference) problems in company with the development of electronic equipments. Accordingly it is also required to construct some anechoic chambers for EMI measurement. Furthermore it is very important to evaluate the chamber characteristics in advance of its construction. For that purpose we have analyzed the characteristics by computer simulation in base on the image method, and compared the results with the measured ones. In case of 3-meter method as a result, the curved line of height pattern of open site varies similarly as that of height pattern of anechoic chamber. When we measure the electromagnetic strength and can get the height pattern curves by frequencies, we utilized it effectively because we can protect instrumental errors in measurement. On the other hand, there is a little difference in site attenuation above 700MHz. When the ferrite grid was used however, the calculated values agree well with the measured values up to 1000MHz with the exception of 30-40 MHz range. The reason is that we don't consider the antenna coupling in the low frequencies of 30-100MHz range.