Recently, Introduced the study of fire resistance design. This paper has been written about the cross-sectional temperature distribution in the square CFT columns are painted in Intumescent paint. Study on the thermal properties Intumescent paint is not yet clear. Thus, the finite element analysis was performed by reference to the properties of other materials. FEM results Were compared with the experimental results. It offer a range of thermal properties considering the thermal mechanism of the fire-resistant paint as a result.