As the scale of structure becomes larger, the temperature crack of massive concrete structure is caused by the phenomenon which the mass concrete volume is restricted in the inside or outside part due to the temperature variations induced by the hydration heat of cement. So, we should prepare the method to reduce reasonably the hydration heat for the control of temperature crack. Therefore, this study presents the hydration heat analysis to verify the control effect of temperature crack when we consider to the different concrete mixtures.