        검색결과 151

        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper investigates the effects of aspect ratio and volume fraction of hooked-end normal-strength steel fibers on the compressive and flexural properties of high-strength concrete with specified compressive strength of 60 MPa. Three types of hooked-end steel fibers with aspect ratios of 64, 67 and 80 were considered and three volume fractions of 0.25%, 0.50% and 0.75% for each steel fiber were respectively added into each high-strength concrete mixture. The test results indicated that the addition of normal-strength steel fibers is effective to improve compressive and flexural properties of high-strength concrete but fiber aspect ratio had little effect on the modulus of elasticity and compressive strength. As steel fiber content and aspect ratio increased, flexural beahvior of notched high-strength concrete beams was effectively improved.
        4,000원
        2.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 경화 시 발생하는 수분증발로 인한 건조수축은 콘크리트의 균열을 발생시킨다. 콘크리트에 발생하는 균열 은 콘크리트의 내구성을 저하하여 안정성과 사용성에 문제를 발생시킨다. 이러한 문제점을 보안하기 위해 콘크리트에 강섬유를 혼입하여 건조수축으로 인한 균열을 방지하는 강섬유 보강 콘크리트 (SFRC)에 관한 연구가 진행되고 있다. 강섬유는 콘크리트 의 균열단면에서 가교역할, 부착작용을 통해 건조수축으로 인한 균열발생을 억제하고 균열 폭을 감소시키는 효과가 있다. 본 논 문에서는 강섬유의 인장강도에 따른 강섬유 보강 콘크리트의 건조수축 제어성능을 평가하였다. 자유건조수축 실험과 구속건조 수축 실험을 진행하였으며 실험 결과를 콘크리트의 인장응력으로 변환하여 콘크리트 직접인장실험 결과와 비교하였다. 강섬유 의 자유건조수축 저감 효과는 미미하지만 강섬유의 인장강도가 증가할수록 구속건조수축으로 인한 균열제어에 효과적임을 확인 하였다. 또한 강섬유의 인장강도가 증가할수록 콘크리트의 인장응력이 증가함을 확인하였다.
        4,000원
        3.
        2017.04 구독 인증기관·개인회원 무료
        The concrete wall panels are composed of various members such as studs, brackets, bolts and nuts, etc. Embedded studs in the concrete wall resist transferred lateral and horizontal load in the structure. The thickness of the concrete wall influences shear behavior of embedded studs. The finite element analysis was carried out with respect to the thickness of the concrete wall to investigate shear behavior of embedded studs. The numerical analysis results were compared with the experimental results and confirmed that The deformation of the stud anchor is reduced with an increase of the thickness of the concrete wall.
        4.
        2008.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 원전 주제어실의 3차원 층 지진격리시스템에 대한 지진동 저감성능과 적용성을 평가하기 위해서 실험연구를 수행하였다. 3차원 층 지진격리시스템에 적용하기 위해서 마찰진자시스템과 에어 스프링을 설계하고 제작하였다. 제어 캐비닛과 액세스 플로어, 격자 프레임, 4개의 마찰진자와 에어 스프링으로 구성된 원전 주제어실 부분 실험모형을 2종류 제작하여 층 지진격리시스템의 원전 적용성을 평가하였다. 실험을 위해서 원전 주제어실의 운전기준지진(OBE)과 안전정지지진(SSE)의 수직방향, 수평방향 층 응답 스펙트럼을 이용하여 인공지진 시간이력을 만들어서 진동대 실험에 사용하였다. 입력지진에 대한 실험모형의 지진응답은 비 지진격리에 비해 3차원 층 지진격리시스템을 적용한 경우, 우수한 지진동 저감특성을 나타냈다
        4,000원
        5.
        2019.11 KCI 등재 서비스 종료(열람 제한)
        본 논문은 비내진 상세를 갖는 철근콘크리트 골조 및 필로티 건물의 보강방법으로 높은 연성을 갖는 ECC를 적용한 PC 벽판을 내진 보강요소로 사용하고자 하였다. PC 벽판의 형상비 및 설치 위치를 변수로 RC 골조에 대한 반복가력실험을 실시하여 내진성능을 평가하였다. 실험결과 PC 벽판을 보강함에 따라 기존 RC 골조의 내력 증진, 강도저하 방지, 강성증진 및 에너지 소산능력 향상에 효과적인 것으로 나타났다. 실험결과를 근거로 비내진 상세를 갖는 골조의 강도 증진을 위하여 ECC PC 벽판을 골조의 중앙에 설치하고 연성증진을 위하여 세장한 벽판을 골조의 양측면에서 설치할 것을 제안한다.
        6.
        2019.10 서비스 종료(열람 제한)
        최근 건설분야에서도 스마트(Smart)라는 개념을 도입한 재료 및 구조방식의 개발에 관한 관심이 고조되고 있다. 특히 기존 콘크리트와 같은 시멘트 복합체에 다양한 전도물질을 혼입하여 외력의 작용시 유발되는 변형을 시멘트 복합체의 저항변화로 평가하는 자기 감지형 건설재료 개발 연구가 활발히 진행되고 있다. 통상적으로 시멘트 복합체는 인장변형에 대한 저항능력이 낮기 때문에 주로 압축변형과 전기적인 저항특성의 상관성을 평가하는 연구 즉, 압축변형 감지능력을 갖는 시멘트 복합체 개발에 관한 연구가 대부분이었다. 본 연구에서는 직접인장하에서 0.5% 인장변형시까지 자기 감지능력을 갖는 변형 경화형 시멘트 복합체(SHCC)를 개발하고 또한 철근의 보강이 SHCC의 자기 감지능력에 끼치는 영향을 평가한다.
        7.
        2019.07 KCI 등재 서비스 종료(열람 제한)
        주차장 바닥재로 많이 사용되는 A사 에폭시 코팅제와 B사 바닥코팅제(A, B type)에 대하여 GC/MS(Gaschromatography /Mass spectrometer)를 이용하여 제품별로 함유하고 있는 휘발성유기화합물(VOCs)의 종류와 함량을 측정해보고, 휘발성유기화합물(VOCs)중 작업자나 입주자들에게 유해한 폼알데하이드(Formaldehyde), 톨루엔(Toluene), 크실렌(Xylene)을 외부 환경에 따른 오차를 줄이고자 가장 안 좋은 (밀폐) 환경을 가정하고 가스검지관을 이용하여 가스배출량을 측정해 보았다. 그 결과 A사 에폭시코팅제가 제품 자체에도 휘발성유기화합물(VOCs)을 가장 많은 양 함유하고 있고, A사 에폭시코팅제에 비하여 B사 바닥코팅제 A type은 약 79%, B type은 약 96% 이상의 적은 양을 나타냈다. 또한, 밀폐된 환경 조건에서 1시간과 8시간 경과 후 가스검지관을 이용하여 폼알데하이드(Formaldehyde), 톨루엔(Toluene), 크실렌(Xylene)에 대한 가스배출량을 측정하고 TWA값으로 환산한 결과에서도 A사 에폭시코팅제가 가장 높게 측정되었다. A사 에폭시코팅제보다 B사 바닥코팅제 A type은 약 42.3%이상의 적은 측정값을 나타냈으며, B type의 경우 밀폐된 환경 조건에서도 시간가중평균노출기준(TWA)을 모두 만족하였다.
        8.
        2019.05 KCI 등재 서비스 종료(열람 제한)
        본 논문은 기존 RC 보강방법인 철골프레임 적용방법의 단점을 보완하고자, 접합철물을 최소화하고 팽창형 모르타르를 사용하여 H형강 프레임을 기존 RC 골조에 보강하고자 하였다. 철골프레임 적용 유․무를 변수로 RC 골조에 대한 반복가력실험을 실시하여 내진성능을 평가하였다. 철골프레임을 적용한 RC 골조의 최대내력이 기존 RC 골조에 비해 약 1.4배 향상되었으며, 등가점성감쇠비 평가결과 또한 평균 2.4% 향상되어 에너지 소산능력이 개선되었다. 유한요소해석결과 해당 실험결과가 신뢰성을 가질 수 있는 것으로 판단된다.
        9.
        2019.05 KCI 등재 서비스 종료(열람 제한)
        본 연구는 강섬유의 인장강도 및 형상비가 고강도 및 보통강도 강섬유보강 콘크리트(Steel fiber-reinforced concrete, SFRC)의 압축 및 휨 거동에 미치는 영향을 평가하기 위하여 실시되었다. 또한 본 연구에서는 가력속도에 따른 SFRC의 압축거동을 평가하였다. 이를 위해 총 4종류의 강섬유가 설계기준 압축강도 35 및 60 MPa급 SFRC에 각각 사용되었다. 압축거동 평가를 위해 지름 150 mm 및 높이 300 mm의 원주형 공시체를 사용하였으며, 단면 150×150 mm 및 지간 450 mm의 각주형 공시체를 사용하여 휨 거동 평가를 실시하였다. 실험결과 강섬유의 혼입은 콘크리트의 인성을 크게 향상시키는 것으로 나타났으며, 고강도 강섬유의 사용은 고강도 SFRC의 성능개선에 효과적인 것으로 나타났다. 아울러 본 연구에서는 SFRC의 휨 인성지수에 근거한 압축인성지수 산정기법을 제안하였다.
        10.
        2019.05 KCI 등재 서비스 종료(열람 제한)
        본 연구는 콘크리트 내부 공극 및 계면 사이에 깊게 침투가 가능한 실란복합화합물을 기반으로한 표면보호재 (Silane Surface Protection Material, SSPM)를 사용한 기존 콘크리트 내구성 향상 방안 도출을 위해 실시되었다. SSPM을 적용한 모르타르의 미세구조 평가, 잔골재의 입도 분포에 따른 침투깊이 및 공극량을 측정하였다. 그 결과 모르타르 내부에 액상 및 크림형질의 SSPM이 침투된 것으로 나타났으며, 공극량 평가결과 잔골재의 입도분포에 관계없이 SSPM을 적용하였을 때 공극량이 감소하는 것으로 나타났다. 침투깊이 평가결과 잔골재의 입도분포에 관계없이 SSPM 도포량이 증가함에 따라 침투깊이가 증가하는 것으로 나타났으며, 공극량이 상대적으로 많은 일반잔골재(Type 2)로 제작한 모르타르의 침투깊이가 적게 나타났다. 콘크리트에 적용할 경우 침투깊이는 다소 감소할 것으로 판단되나, 콘크리트 표면에 침투하여 내구성을 향상 시길 수 있을 것으로 판단된다.
        11.
        2019.04 서비스 종료(열람 제한)
        In this paper, fracture behavior of high-strength SFRC with high tensile strength steel fiber was investigated. Two different steel fibers with tensile strength of 1,200 and 1,600 MPa was used in SFRC specimens. Tst results showed that fracture behavior was more ductile with increasing the steel fiber tensile strength.
        12.
        2019.04 서비스 종료(열람 제한)
        In this study, the effect of compressive loading of carbon nanotube (CNT) mixed cement composites was investigated. To evaluate the electrical resistivity variation of 30%∼60% of compressive load of cement composites containing 1.0% CNT, 1.0% CNT was added to cement composites and compressive strength was calculated. The greater the change in electrical resistance to compressive load, the more vulnerable to internal conductive networks. Also, as the amount of CNT mixed increases, the electrical resistance to the load is more sensitive and it is expected to be mixed more than 1.0%.
        13.
        2019.04 서비스 종료(열람 제한)
        This paper describes the mechanical properties of high strength concrete with 1,600 MPa strength steel fiber. The fiber aspect ratio and fiber volume fraction used in this study is 80 and 0.75%. The Cylindrical specimens with ∅150×300 mm and the prisms with 150×150×550 mm were mad and tested in accordance with KS F2403 and ASTM C1609. As the result, specimens with high strength fiber has superior performance then that with normal strength fiber.
        14.
        2019.04 서비스 종료(열람 제한)
        This study was conducted to evaluate the effect of self-sensing performance on strain-hardening cement composite containing CNT by curing age. The mixing amount of CNT was set at 1.0%, and SHCC fibers were mixed with PE 1.0% and steel fiber 0.5%. The electrical resistance measurement for the tensile strain sensing performance was based on AC method and 4 probe methods. Test results indicated that electrical sensitivity of SHCC decreased with an increase in curing age.
        15.
        2019.04 서비스 종료(열람 제한)
        In this paper, finite element analysis of high-strength SFRC with high tensile strength steel fiber was investigated. Compressive and flexural behavior was ductile when using steel fiber tensile strength 1,600 MPa. Thorenfeldt and Trilinear models were used to describe the compressive and tensile behavior. Inverse analysis was performed to construct tensile model by evaluating flexural behavior. The flexural behavior of test results were similar to analysis results.
        16.
        2019.04 서비스 종료(열람 제한)
        This research uses carbon nanotubes (CNTs) that are actively used to develop convenient and systematic management of building blocks and structural performance monitoring, away from the difficulties of structural health monitoring such as RC structures. The change in electrical resistance was evaluated according to the amount of load and compressive load. Experiments were carried out with 1.0% and 2.0% CNT, and 30% and 60% compressive strength, respectively. Experimental results show that the compressive strength of CNT 2.0% is lower than the compressive strength of CNT 1.0% but is more sensitive to changes in electrical resistance due to compressive load.
        17.
        2019.04 서비스 종료(열람 제한)
        This study investigates the mechanical properties of SFRC reinforced by mixing different steel fibers with compressive strength of 70 MPa. In this study, The fiber aspect ratio consist of 60 and 80 and tensile strength is 1,100 MPa used. Cylindrical specimens with a ∅150×300 mm were made fo compression test, and prismatic specimens with a 150×150×550 mm were made fo flexural and direct shear tests. Test results show that the superior compression performance was observed in SFRC with Mixing different steel fibers.
        18.
        2019.04 서비스 종료(열람 제한)
        In this research, Sensing Performance in Tensile Strain of Strain-Hardening Cement Composites by Containing of Carbon nanotube have been studied. The ultimate strength and strain were improved with increasing in amounts of CNT, and fractional change in resistivity were improved when same tensile strain. and %LE were decreased with increasing in amounts of CNT.
        19.
        2019.04 서비스 종료(열람 제한)
        This paper describes the effect of tensile strength and aspect ratio of fiber on compressive and flexural toughness index of high- and normal-strength steel fiber-reinforced concrete(SFRC). For this purpose, eight types of SFRC mixtures were made and tested. Test results indicate that the compressive and flexural toughness index of SFRC increased with increasing in tensile strength and aspect ratio of steel fiber.
        20.
        2019.01 KCI 등재 서비스 종료(열람 제한)
        스트론튬계 상전이물질은 특정한 온도에서 물질의 상태가 변함에 따라서 열을 흡수하거나 방출하게 된다. 본 연구의 목적은 스트론튬계 상전이물질의 혼입이 플라이애시 치환 모르타르 및 고로슬래그 치환 모르타르의 수화발열 및 역학적 특성에 미치는 영향을 실험적으로 평가하는 것이다. 스트론튬계 상전이물질의 혼입량은 결합재 질량의 1, 2, 3, 4, 5%로 하였다. 총 12개 수준의 모르타르 배합에 대해서 모르타르 흐름성능, 간이수화열온도상승, 압축 및 휨강도 실험을 각각 수행하였다. 실험결과 본 연구에서 사용한 스트론튬계 상전이물질은 모르타르의 수화열 저감 및 수화지연에 효과적인 것으로 판단된다. 특히 플라이애시 치환 모르타르의 최대온도 상승량은 고로슬래그 치환 모르타르의 최대온도 상승량에 비해 낮게 나타났다. 플라이애시 및 고로슬래그 치환 모르타르의 압축강도는 상전이물질 혼입량이 증가함에 따라 감소하는 것으로 나타났다.