논문 상세보기

S시 대형폐기물 기타협잡물의 SRF적용 가능성 평가 KCI 등재

A Feasibility Assessment on the Energy Potentical of Inclusion of Bulky Waste in Seoul

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/292768
서비스가 종료되어 열람이 제한될 수 있습니다.
한국폐기물자원순환학회지 (Journal of Korea Society of Waste Management)
한국폐기물자원순환학회 (Korea Society Of Waste Management)
초록

The MOE (Ministry of Environment) had classified 4 types of solid fuels as RDF (Refuse Derived Fuel), RPF (Refuse Plastic Fuel), TDF (Tire Derived Fuel) and WCF (Wood Chip Fuel) in Korea at 2012. However, the MOE has reclassified, the solid fuels with SRF (Soild Recovery Fuel) and Bio- SRF. Since the qulity standard for SRF has moderated, it is easier and more economical to recycle the waste. In this study, investigation for the generating, collecting, transporting, and treatment system of bulky waste in Seoul were performed. Moreover, experiments conducted to the analysis of collected bulky waste for assessment of SRF. According to the report of waste -meter-rate system in 2010, amount of bulky waste from to Dongdaemun-Gu is similar to average emissions in Seoul, and have an important facilities of transshipment for bulky waste, so that is the reason to select Dongdaemun-Gu for this research. According to process of Dongdaemun-center, bulky waste is classified into four-case, as metals, sponges, woods, and inclusion. Because the potion of inclusion is the difficult material to recycle, the entire quantity generated has been incinerated in Dongdaemun-Gu. the incinerating cost for inclusion was about 300 million won in 2012. Thus, inclusion from bulky waste was taken the target material to apply for SRF. So selected as inclusion that was incinerated to apply the SRF fuel standard. This research was analyzed the change in characteristics related to bringing location and period in order to evaluate the potential of energy of bulky waste in seoul. As a results of evaluation, there is not any differences related to changes of location and period. In addition, the results of conformity assessment of quality standards. Assessment items were satisfied with quality standards without moisture content. Moreover, low caloric value that is the primary factor to apply SRF was about 4,000 Kcal/kg Which is the homogeneous energy to utilize as fuel. However, taking steps as shield system for control of increasing moisture content by rainfall would be required.

저자
  • 문희성(서울시립대학교 환경공학부) | Hee-Sung Moon
  • 김진식(서울시립대학교 환경공학부) | Jin Sik Kim
  • 문소영(서울시립대학교 환경공학부) | So young Moon
  • 김신도(서울시립대학교 환경공학부) | Shin Do Kim
  • 이재영(서울시립대학교 환경공학부) | Jai-Young Lee Corresponding author