논문 상세보기

건축용 페인트의 실내공기오염물질 배출특성 연구

A Study of the Paint Characteristic Emission of Indoor Air Pollution Materials for Building Complete Materials

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/292834
구독 기관 인증 시 무료 이용이 가능합니다. 4,800원
大田大學校 環境問題硏究所 論文集 (대전대학교 환경문제연구소 논문집)
대전대학교 환경문제연구소 (The Institute of Environmental Studies)
초록

In this study, the paint, which has very close relationship to the of indoor air quality, was examined for the air pollution leveling test, and using the various passive sampler, the test was evaluated on the regard of TWA(Time Weighted Average). This study is to examine how the air pollution levels differ between the regular paint that is used for public and the new developed environment friendly paint. The consecutive experiments were performed in the small chamber test to investigate the VOCs and formaldehyde, ammonia emissions and characteristics from paint which are commonly used as the complete material of building. In conclustion, the natural paint showed the highest emission of VOCs among the selected paints, and water paint showed the highest contents of ammonia. Formaldehyde showed N.D(Not Detected) in most of tests and found a small amount in vinyl paint however, it was not as bad as to fail the certify level of building materials. It is recommended to constantly develop the chamber system and it will be very much possible to be used for the estimation of indoor air pollutants from the various paints and other complete materials.

저자
  • 김선태(대전대학교 환경공학과) | Sun-Tae Kim
  • 하덕호(대전광역시 보건환경연구원) | Duk-Ho Ha
  • 이규성(대전대학교 환경공학과) | Kyu-Sung Lee
  • 손찬웅((주)보성엔비텍) | Chan-Woong Son