논문 상세보기

FRP Hybrid Bar를 적용한 RC보의 부식에 따른 내력저하

Reduction of Flexural Capacity in RC Beam Considering Corrosion

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/299550
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

In the paper, newly invented FRP Hybrid Bar and normal steel are embedded in RC beam member, and ICM(Impressed Current Method) is adopted for corrosion acceleration. Corrosion amount level of 4.9∼7.8% are measured in normal RC member and the related reduction of flexural capacity is measured to –25.4∼-50.8%. But, durability evaluation through long-term submerged condition is required for actual utilization.

저자
  • 최세진(원광대학교 건축공학과 교수) | Choi, Se Jin
  • 이학수(한남대학교 건설시스템공학과 교수) | Lee, Hack Soo
  • 문만진(한남대학교 건설시스템공학과 석사과정) | Mun, Jin Man
  • 박기태(한국건설기술연구원 구조융합연구소 연구위원) | Park, Ki Tae
  • 권성준(한남대학교 건설시스템공학과 교수) | Kwon, Seung Jun