전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구 KCI 등재

Study of radiation exposure on human body using of Computed Tomography

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/310712
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
대한안전경영과학회지 (Journal of Korea Safety Management & Science)
대한안전경영과학회 (Korea Safety Management & Science)
초록

This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers’ health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.

저자
  • 선종률(대전보건대학교 방사선과) | Jong-Ryoul Seon Corresponding Author
  • 유세종(건양대학교병원 영상의학과) | Se-Jong Yoo