        1.
        2016.04 구독 인증기관 무료, 개인회원 유료
        A door of radiation therapy room needs enough shielding ability. However, radiation therapy room needs quick enter for safety of patients. Therefore, To evaluate the shielding ability and stability of each room construction, door format, and control button position. Material is 8 room construction, 6 door format, and 3 control button position. It was compared time and leakage dose according to each type. The hinged door type with handle was best of patients stability, and the sliding door type was best of shielding ability. It is considered necessary, standard on the provision of door format and position of control button about each construction of radiation therapy room.
        4,000원
        2.
        2016.04 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 임상의 핵의학, PET 진단 분야에서 진단 시에 사용되는 방사성 동위원소 중 18F를 이용하여 납가운의 두께 별 에너지스펙트럼을 측정하고 납가운 0.3, 0.5mmPb에 대한 차폐율을 측정하고자 하였다. 에너지 스펙트럼 측정의 경우 자체 제작한 방법으로 측정하였고 차폐율 및 선량 측정의 경우 납가운과 선원의 거리에 대 해 선원과 측정기에 대해 납 가운의 위치를 달리 하여 3가지 조건으로 나누어 각각 20회씩 측정을 하여 평균값을 산출하였다. 에너지 스펙트럼 상에서는 납가운을 위치하 였을 때 본래 방사성 동위원소로부터 방출되는 에너지 외의 에너지 피크영역이 측정 되었고 차폐율 및 선량측정에서는 방사성동위원소 18F은 납가운을 이용하여 차폐를 할 경우 차폐율이 매우 미비하거나 음수의 값이 측정되었다.
        3,000원
        3.
        2016.04 구독 인증기관 무료, 개인회원 유료
        CT scan 시 X-ray tube는 환자를 중심으로 360° 회전을 하기 때문에 산란선은 모 든 방향에서 발생한다. 임상에서 환자의 피폭을 감소시키기 환자의 흉·복부 전면만을 차폐하고 환자 후면이나 측면에서 발생되는 산란선에 대한 차폐는 시행하고 있지 않 다. 두부(Brain) CT 검사 시 흉부 및 복부에 입사되는 산란선을 ion chamber로 측정 하여 그 분포를 확인하고 두부 CT 검사 시 발생되는 산란선의 분포를 통해 기존 차폐 방법의 적정성을 평가 하고자 한다. 연구결과 gantry angle이 클수록, 전면보다 후면에 서 산란선이 많이 발생했다. 두부 CT 검사 시 발생되는 산란선에 의한 피폭을 최소화 하기 위해 가급적 gantry angle을 작게 줄 수 있도록 환자 두부의 위치를 조정하여 검 사를 하거나 납치마를 이용하여 환자의 흉·복부를 차폐할 경우 전면 뿐 아니라 양 측 면과 후면을 납치마를 이용하여 차폐를 해야 할 것이다.
        4,000원
        4.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Beam hardening artifact can be caused by metal material when performing PET exam. Therefore, we studied a solution decreasing artifact caused by metallic dental implant. The higher voltage, the lesser artifact in CT exam. But Higher voltage dosen't affect PET exam. The thicker silicon the lesser artifact in CT and PET exam. Both methods make less artifact in CT and PET exam. But considering safety of patient, the way of using silicon is better.
        4,000원
        5.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Chest lateral decubitus is a chest examination to determine the persence of pleural fluid in thorax. In this study, we prepare recumbent holding position time standard of chest lateral decubitus. The records of 15 patients with chest lateral decubitus between May and Jun. Recumbent holding time is 30, 60, 90, 120, 180, 210, 240 seconds. The result is fluid level change between 0.88mm to 9.63. Fluid heigh change between 9.9 percent to 42.5 percent. We can confirm fluid level change with chest decubitus image. The proper time for fluid level change is 180 seconds.
        4,000원
        6.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers’ health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.
        4,000원
        8.
        2015.11 구독 인증기관 무료, 개인회원 유료
        최신의 방사선치료 기법 중의 하나인 체적변조회전치료의 경우 치료 시 방사선은 회전하면서 연속조사를 실시하는 반면 치료계획상에서는 1도 간격의 고정조사형태로 계획되게 된다. 이에 본 연구에서는 체적변조회전치료계획의 정확성을 평가하고자 하 였다. 연속조사에 대한 치료계획이 불가능하므로 3구간에 대해 0.2도 간격, 0.5도 간격, 1.0도 간격, 2.0도 간격으로 치료계획을 실시하여 6개의 용적에 대해 처방선량의 50% 와 70% 용적에 대한 V50과 V70의 평가지표를 비교하였다. 그리고 평가지표 별 용적 에 대한 선속간격 그래프를 통해 연속조사에 대한 값을 외삽하여 추정하였다. 그리고 외삽된 연속조사의 값과 1도간격인 치료계획의 값을 비교하여 오차값을 획득하였다. 그 결과 V50에서는 최대 9.46%의 차이를 보였으며, V70의 경우 최대 25%의 차이를 보였다. 이를 통해 체적변조회전치료계획의 경우 선량의 부정확성을 인지하면서 치료 계획을 실시하여야 하며, 치료계획 컴퓨터의 개발 시 1도 간격이 아닌 본 연구의 결과 에서 처럼 0.5도 간격으로 재설정하여야 할 것이다. 물론, 간격이 좁아지면 계산속도가 느려지므로, 2단계에 걸쳐 계산하는 시스템의 도입도 고려해보아야 할 것이다.해야 할 것이다.
        4,000원
        9.
        2015.11 구독 인증기관 무료, 개인회원 유료
        The private fixed device is needed for a radiation therapy about breast cancer. But this option is wrong applies to every hospital. Thereupon, we will establish standard of option for body-specific. 42 patients on 4 months were enrolled. The option of fixed device applied to divide into 6 kinds. The images were analyzed by OBI. In result, It is excellent reproducibility of position by all body-specific that It is applied head holder, shoulder holder, cotton, kneefix.
        4,000원
        10.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Through the inspector's real name to improve the quality of inspection is to show the design Radiological examination pursuant to the Ordinance of the Ministry of Health and Welfare for patient safety in the Image. However, the use of existing and in EMR, equipment within the handwriting input, the individual initial use has a problem. In this study, increasing the stability of the patient and the precise inspection, In order to increase the efficiency and convenience than the real-name system for quality control inspectors of medical equipment, Using the EMR and PACS developed and applied to evaluate the usefulness of automatic enrollment. Enter your information in the EMR, which was developed markers that inspectors use to compare the before and after images PACS satisfaction. Convenience than using traditional, consistency, the entry of the missing were higher as a statistically significant difference. A test strip automatic enrollment programs are developed in this study. You can increase the stability of the patient by checking the image to show the real tester, we expect the quality of care would be improved.
        4,000원
        11.
        2015.04 구독 인증기관 무료, 개인회원 유료
        선형가속기의 선량평가를 위한 멸균증류수를 사용 시 보존기간에 따른 불순물 유입 으로 탁도가 변화로 선량값의 오차가 발생하게 된다. 이에 탁도 측정을 통한 멸균증류 수 교체기준 및 교정계수를 획득하고자 한다. 물팬텀 내 멸균증류수를 2주 간격으로 8회에 걸쳐 탁도를 측정하고 10MV 광자선을 이용하여 선량을 측정하였다. 측정결과 탁도증가에 따른 선량오차는 비례관계를 보이며, 허용오차인 3%에 대치되는 탁도는 2.8 NTU로 나타났다. 이를 통해 선량측정 시 탁도를 측정하여 해당 교정계수에 적용 하여야 하며, 탁도가 2.8 NTU를 넘는 경우에는 멸균증류수를 교체하여야 할 것이다. 향후 이를 통해 선형가속기의 절대선량 평가가 별도로 이루어진 실험 및 탁도의 세분 화에 따른 교정계수 산출을 통한 연구의 기틀을 마련하고자 하였다.
        3,000원
        12.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Techniques, using physical wedge filter and using dynamic wedge filter and FIF(Field in Field) and ISCT(Irregular Surface Compensating Technique), have been developed according to progress of radiation therapy of breast cancer. Measurement of dose was done to judge the usefulness of technique using three cases, non tissue loss after breast conserving operating and tissue loss after breast conserving operating and mastectomy. Dose indexes of breast tissue, CI (Conformity Index), HI (Homogeneity Index) and QOC (Quality of Coverage), dose index of skin, or dose indexes of lung, volume of 50 percent dose and 20 percent dose were estimated and compared. Using dynamic wedge filter is useful plan at non tissue loss allowing for high dose of lung. FIF and ISCT are useful plan at tissue loss. ISCT is useful plan at mastectomy. Henceforth, we need to apply to valid plan and body type and thorax size.
        4,000원
        13.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        According as radiation therapy technique develops, standardization of radiation therapy has been complicated by the plan QA(Quality Assurance). However, plan QA tools are two type, OADT (opposite accumulation dose tool) and 3DADT (3 dimensional accumulation dose tool). OADT is not applied to evaluation of beam path. Therefore tolerance error of beam path will establish measurement value at OADT. Plan is six beam path, five irradiation field at each beam path. And beam path error is 0 degree, 0.2 degree, 0.4 degree, 0.6 degree, 0.6 degree, 0.8 degree. Plan QA accomplishes at OADT, 3DADT. The more path error increases, the more plan QA error increases. Tolerance error of OADT path is 0.357 using tolerance error of conventional plan QA. Henceforth plan QA using OADT will include beam path error. In addition, It will increase reliability through precise and various plan technique.
        4,000원
        14.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The study enrolled 30 patients who patient with uptake in stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was 61.7±9.7 mm, horizontal length was 102.5±17.6 mm and the vertical length of the Blowing agent group was 74.1±10.7 mm, horizontal length was 101.5±14.8 mm in transverse section. Stomach extension was described as the vertical length of the Water drink group was 109.3±18.8 mm, horizontal length was 62.7±18.4 mm and the vertical length of the Blowing agent group was 123.1±23.1 mm, horizontal length was 87.6±14.9 mm in coronal section. Water drink group SUV decreased 35% and Blowing agent group SUV decreased 56%. Blowing agent group extension was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.
        4,000원
        15.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we quantitatively analyzed the data by measuring the radiation shielding rate and uniformity in order to evaluate the performance of an Apron. In addition, storage conditions were also evaluated. The uniformity measurement was performed by evaluating the Apron DICOM images using a PACS program. The experiment was intended for 51 Aprons being used in three hospitals in the Daejeon area. The radiation shielding rate and uniformity were measured per lead equivalent for 0.25 mmPb, 0.35 mmPb, and 0.5 mmPb. As a result, the higher lead equivalents were, the greater differences in the non-uniformity between the top part and the bottom part became (p=0.020). In all hospitals, regarding the non-uniformity of four places in Aprons, all showed statistically significant differences (p<0.01). The average value of the transmitted radiation dose showed less difference (p = 0.005) in the bottom right than in the upper right but was statistically significant. There have been no marks of manufacturing date or the date of purchase in the Apron.
        4,000원
        16.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ±1%, ±2% at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.
        4,000원
        17.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to monitor the current adverse reactions in administering CT contrast agents at general hospitals and also to suggest the practical guidelines to minimize the risk and to show the successful patient management. At four Dajeon city general hospitals, the contrast agents were administered in 646,828 cases and the overall prevalence of adverse reactions was 4,110 cases from January 2010 to December 2013. However, we excluded the two hospitals’ 3,658 cases because the patients’ data was inadequate. Consequently, the case surveys on the rest of 452 cases have been studied and submitted. After comparing the patients with a control group, we evaluated that the key factors of the adverse reactions were the gender and age difference of the patients, the examination period, the examination method, the quantity and administrating speed of the contrast agents. Even though the four general hospitals have their own management systems on adverse reactions, but their systems were not satisfying. To improve the quality of the management systems and to investigate further cases, some hospital administration procedures on the subject should be systemized and general hospitals should follow the recommended procedures. Moreover, the existing three-year-term evaluation should not only judge the adverse reaction management but also conclude some details on the sub criteria of the evaluation. The details on the sub criteria include the contrast agent characters, the quantity and administrating speed of the drug, the incidents’ occurred time, an anamnesis; a case history, the medical history of the patients and the reaction occurring body parts, and the examination title. The details of the medical examiners are also added to the sub criteria.
        4,000원
        18.
        2014.11 구독 인증기관 무료, 개인회원 유료
        본 연구는 조영제를 사용하는 CT검사에서 조영제 부작용이 발생한 환자에 대한 정보를 수집하고 분석하여 조영제 부작용 발생인자들을 분석하여 조영제 부작용을 미리 예측하고 예방하여 조영제 부작용 발생빈도를 최소한으로 줄이고자 하며, 병원 내 약물부작용 관리 업무에 기초자료로 활용하여 병원의 진료 서비스의 향상과 영상의학과 종사자들의 업무 효율성을 증대시키고자 한다. 연구 대상은 대전광역시에 소재하는 4개의 종합병원에서 조 영제를 사용하는 CT 검사 중 만 18세 이상 남녀를 대상으로 2010년 1월부터 2014년 7월 까지 전산으로 기록되어진 4,932명 중 변수가 부족한 데이터를 제외하고 조영제 부작용이 발생한 환자 404명(이하 환자군)과 같은 기간 조영제 부작용이 발생되지 않은 환자에서 조영제 부작용이 발생한 환자의 성별, 조영제 종류를 교차하여 무작위 추출을 한 404명 (이하 대조군)을 대상으로 분석하였다. 기존에 알려진 위험 인자에 대해서 본 연구에서는 일반적 특성에 따른 조영제 부작용은 계절에 따른 특성에서 봄에 검사한 환자보다 겨울에 검사한 환자가 조영제 부작용 발생확률이 높게 나타나는 것으로 유의한 차이가 있었고, 다른 특성에서는 유의한 차이가 없었다. 조영제 부작용검사 관련 특성에서는 일반적인 검 사보다는 Dynamic 검사 시 조영제 부작용 발생확률이 높게 나타났고, 조영제 사용량이 130ml 이상 시, 주입속도가 4F/R 이상 시 조영제 부작용 발생확률이 높게 나타나는 것으 로 모든 특성들이 유의하게 차이가 나타남을 알 수 있었다. 계절적 변화에 따라 환자의 조영제 투입 시 세심한 주의가 필요하리라 생각되며, 매년 CT검사가 증가하고 있는 만큼 조영제 사용이 증가 할 것으로 예상되기 때문에 조영제 부작용의 일반적 특성뿐만 아니라 질병, 전처치, 심리적 요인, 기타 약물 복용, 등의 다양한 원인을 근거로 한 연구가 지속적 으로 진행되어야 하며 이러한 연구들을 통해 조영제 부작용의 발생 위험을 사전에 예방할 수 있는 체계적이고 효율적인 프로그램의 개발이 필요하리라 생각된다.
        4,000원
        19.
        2014.11 구독 인증기관 무료, 개인회원 유료
        검사자 실명제를 통하여 검사의 질적 수준을 높이기 위하여 보건복지부령 제 3조 1 항 중 [1. 운용인력기준-방사선사-전속 1인]으로 되어 있으며, 보건복지부령 제 5조 제 2항<개정 2011.6.27 > 중 [다. 유방촬영용 장치-촬영표지-9.촬영자 성명(기호)]에 검사 자인 방사선사를 표시하도록 되어 있다. 이에 본 연구에서는 검사자 실명제를 효율성, 신뢰성, 편의성을 보다 높이기 위하여 EMR과 PACS를 이용하여 자동 등록 프로그램 을 개발하여 적용하였다. 2013년 3월~4월까지 특수의료장비를 운용하는 방사선사 총 55명을 대상으로 검사자의 영상 입력 방법에 대해 타당성 및만족도 조사를 시행하였 으며, 프로그램개발은 2013년 4월부터 12월까지 비쥬얼베이직 6.0 Version(VB6)을 이 용하여 의료영상정보시스템(PACS)과 병원정보시스템을 연동하는 프로그램을 구현하 였다. 프로그램 개발은 검사실 등록은 획득서버에서의 [Description Name]을 Text로 변환한 것이며, 방사선사 등록은 인사 D/B에서 ‘RT’로 등록되어 있는 사번과 한글이 름을 연동시켰으며, 검사 후 DICOM 파일을 획득 할 때 DICOM Tag 값인 [0x00081070]에 Value 값을 RIS에서 가지고 온 방사선사 사번이 입력되도록 획득서버 의 "Edit Value", Trim(Right(cmbGisa.Text, 6))]에 직접 입력시켰다. 사용 전후 만족 도를 시행한 결과 편의성, 일치성, 누락에서 모두 개발된 프로그램이 만족도가 통계적 으로 유의한 차이로 높게 나타났다. 본 연구에서 개발한 검사자 자동 등록 프로그램은 실제 검사자를 영상에 보여주게 함으로써 환자의 검사 안정성을 높일 수 있으며, 의료 의 질적 수준을 높일 수 있을 거라 기대한다.
        4,000원
        20.
        2014.11 구독 인증기관 무료, 개인회원 유료
        When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The record of 30 patients with local or total uptake of stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was 61.7±9.7 mm, horizontal length was 102.5±17.6 mm, the vertical length of the Blowing agent group was 74.1±10.7 mm, horizontal length was 101.5±14.8 mm in transverse section. Stomach extension was described as the vertical length of the Water drink group was 109.3±18.8 mm, horizontal length was 62.7±18.4 mm, the vertical length of the Blowing agent group was 123.1±23.1 mm, horizontal length was 87.6±14.9 mm in coronal section. SUV results in decrease 35% for water drink group, decrease 56% for blowing agent. When the use blowing agent group extension of stomach was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.
        4,000원