        1.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Beam hardening artifact can be caused by metal material when performing PET exam. Therefore, we studied a solution decreasing artifact caused by metallic dental implant. The higher voltage, the lesser artifact in CT exam. But Higher voltage dosen't affect PET exam. The thicker silicon the lesser artifact in CT and PET exam. Both methods make less artifact in CT and PET exam. But considering safety of patient, the way of using silicon is better.
        4,000원
        2.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Generally a patient who was injected radiopharmaceuticals for nuclear medicine examination is not an object of isolation. Therefore, when the patient uses toilet, we expect surface contamination of a toilet by radioisotope. The measured value is 25.69Bq/cm2(a restroom near admission and administration), 19.39Bq/cm2(a toilet near department of radiology). The study shows that 9 of 24 locations in controlled area exceed over surface contamination limit. From now on, we should find source of contamination through measurement radioactive nuclide to apply radiation safety management.
        4,000원
        3.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When performing Chest x-ray examination to pregnant woman, normally we shield back side of abdomen. In this situation, scattered rays made by equipment and surrounding structure can enter front side of abdomen. Therefore, in this study, we evaluate suitability of abdomen shield especially to pregnant woman. In case of One shielding material placed back of abdomen, the measured value is 0.676±0.19 uSv/hr. Two shielding material is 0.764±0.04 uSv/hr. Three is 0.685±0.16 uSv/hr. The exposure dose inferred in this study does not excess annual effective dose limit. But It is not mean absolute safety. So we have to minimize occurrence of stochastic effect of radiosensitivity by shielding front side of abdomen of pregnant woman in clinic.
        4,000원
        4.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        According as radiation therapy technique develops, standardization of radiation therapy has been complicated by the plan QA(Quality Assurance). However, plan QA tools are two type, OADT (opposite accumulation dose tool) and 3DADT (3 dimensional accumulation dose tool). OADT is not applied to evaluation of beam path. Therefore tolerance error of beam path will establish measurement value at OADT. Plan is six beam path, five irradiation field at each beam path. And beam path error is 0 degree, 0.2 degree, 0.4 degree, 0.6 degree, 0.6 degree, 0.8 degree. Plan QA accomplishes at OADT, 3DADT. The more path error increases, the more plan QA error increases. Tolerance error of OADT path is 0.357 using tolerance error of conventional plan QA. Henceforth plan QA using OADT will include beam path error. In addition, It will increase reliability through precise and various plan technique.
        4,000원