The evolution of the electro-mechanical impedance (EMI) of piezoelectricity (PZT) sensor was investigated to determine the setting times of fiber reinforced cementitious materials in this study. Penetration resistance test was also conducted to validate the EMI sensing technique. As a result, the setting times of fiber reinforced cementitious materials can be effectively monitored through the EMI sensing technique using an embedded PZT sensor.