초록

The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

목차
1. 서론
 2. 막재료의 구분현재 국내에서 막구조용
 3. 난연 및 방염성능 기준
  3.1 건축물의 내화구조
  3.2 난연 및 방염성능 실험 및 기준
 4. 막재의 난연 및 방염성능 실험
  4.1 막재의 화재 성상
  4.2 막재의 난연 및 방염성능 실험결과
 5. 결론
 감사의 글
 References
저자
  • 김기철(서일대학교 건축과, 부교수) | Kim Gee-Cheol
  • 최광호(남서울대학교 건축공학과, 교수) | Choi Kwang-Ho