The objective of this study is to propose methods to design and analyze a catenary shell using a computer program without experiments and measurements. The intial idea stems from Pendergrast’s study, but his method should be improved. In this study, the process of making catenary shell using computer was reproduced by Grasshopper script. In order to enhance credibility, two models from Grasshopper script were analyzed by SAP2000; one was just a square-based catenary shell, while the other was the re-created shell originated from the Naturtheater Grötzingen. The outcome of analysis was reasonable.
Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.
It is very important to calculate natural frequency of the observatory tower correctly because it is keenly affected by wind response vibration due to its large slenderness ratio, weight and small damping ratio. Additionally, suggestion equation of natural frequency being used in the design phase has considerable difference between actual measured value thereby making it inappropriate to be used in the serviceability design of the observatory tower. Therefore, this paper conducted an ambient vibration measuring on 10 observatory towers through mobile-phone application thereby calculating the natural frequency and comparing the result with the domestic and foreign standards and that of the eigen-value analysis. This paper suggested approximate equation of the natural frequency of the observatory tower; T=0.0266H. The square of the corelation coefficient is 0.940, which is high.
The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.
Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix Ⅱ. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.
The purpose of this study is to present a method that can estimate the height of reaction facilities for large structural experiment through load flow as primary design procedure. The characteristic of the load transmission according to the type of experiment was analyzed to obtain tensile and compressive forces occurring on the reaction facilities. Strong walls that are affected by the bending moment is applied the post-tensioning method, and the strong floor under the control of the tension and compression is designed in accordance with the load flow. And the optimum cross-section of the reaction facilities was obtained by comparing the stresses of the tensile stress and crack the concrete. Through validating elastic analysis, the design results were satisfied a given design conditions.
Modular buildings are constructed by assembling modular units which are prefabricated in a factory and delivered to the site. However, due to a problem of noise between floors, concrete slab is usually poured at the top or bottom level of a modular unit in Korea. This greatly increases the weight of buildings, but designing vertical members of modular units to resist overall gravity loads is very inefficient. In this study, considering domestic building construction practices, feasible structural systems for tall modular buildings are proposed in which separate steel frames and reinforced concrete core walls are designed to resist gravity and lateral loads. To verify performance, a three-dimensional structural analysis has been performed with two types of prototype buildings, i.e., a residential building and a hotel. From the results, wind-induced lateral displacements and seismic story drifts are examined and compared with their limit values. Between the two kinds of buildings, the efficiency of the proposed system is also evaluated through a comparison of the weight of structural components. Finally, the effect of a floor diaphragm on the overall behavior is analyzed and discussed.
Cable structures are lightweight structures of flexible type, cable members have only axial stiffness related to tension, they can carry neither bending nor compression. This study is the analysis of cable truss systems are composed of upper and low cables by connecting bracing cables, the structural principle is based on a tensegrity system by using bracing tension members, discontinuous compression members and continuous tension members. A hanging roof of cable truss system is too flexible against vertical loads, most cable members are stabilized by connecting the prestressed upper and lower cable by bracing cables. A cable truss roof system is formed by adding a set of cables with reverse curvature to the suspension cables. With the sets of cables having opposite curvature to each other, cable truss is able to carry vertical load in both upward and downward direction with equal effectiveness, and then a cable truss acts as load bearing elements by the assemble of ridge cables, valley cables and bracing cables. This paper will be shown the geometric non-linear analysis result of cable truss systems with various sag ratio for deflections and tensile forces, the analytical results are compared with the results of other researchers.