간행물

한국공간구조학회지 KCI 등재 JOURNAL OF THE KOREAN ASSOCIATION FOR AND SPATIAL STRUCTURES

권호리스트/논문검색
이 간행물 논문 검색

권호

제19권 제4호 (2019년 12월) 13

기술기사

학술기사

논문

4.
2019.12 구독 인증기관 무료, 개인회원 유료
Spatial structure does not have columns and walls installed inside, so they have a large space. There are upper structure and substructure supporting them. The response of seismic loads to the upper structure may be increased or decreased due to the effects of the substructure. Therefore, in this study, the seismic response of the upper structure and the floor response spectrum of the substructure were compared and analyzed according to the height of the substructure in the spatial structure where the LRB was installed. As a result, the possibility of amplification of response was confirmed as seismic waves passed though the substructure, which is likely to increase the response of the upper structures.
4,000원
5.
2019.12 구독 인증기관 무료, 개인회원 유료
Recently, the occurrence frequency of earthquake has increased in Korea, and many cultural assets have been damaged. Cheomseongdae is a valuable cultural assets that must be preserved historically and culturally. But, the masonry structure such as Chemseongdae is vulnerable to lateral forces. Therefore, in this study, structural modeling and dynamic analysis are performed to reflect the ground state and structural form of Cheomseongdae. Also, discrete element analysis technique is applied and dynamic behavior characteristics are analyzed according to earthquake load. For this purpose, displacements and stresses according to locations are reviewed and then swelling and distortion are analyzed.
4,000원
6.
2019.12 구독 인증기관 무료, 개인회원 유료
The purpose of the paper is to introduce a system that reduces the occurrence of weak-story in the event of earthquake. Weak-story concentrates deformation on the story and causes all member to collapse before the capacity of all member is reached. This paper introduces Strong-Back system (SB) to protect weak story. SB is a hybrid of zipper frame, tied eccentrically braced frame, and elastic truss system and it is divided into elastic and inelastic areas. Elastic areas prevent the generation of weak story by distributing energy, and inelastic areas dissipate energy through buckling or yielding. In this paper, the seismic performance is evaluated by comparing the four type braced frame with SB through push-over analysis. The four criteria are compared from the base shear, the ductility capacity, the column failure order, and the quantity of brace. As a result, SB proved to have sufficient performance to protect the weak-story.
4,000원
7.
2019.12 구독 인증기관 무료, 개인회원 유료
In this study, an experimental study was carried out to evaluate the bond shear performance according to the shear connector between the glue-laminated timber and steel interface. Ten block shear specimens were fabricated according to the configuration of the adhesive surface of wood and steel. In addition, four test specimens were produced according to the main variable shape of the wood-concrete shear connector. As a result of the block shear test, the shear strength of the steel-wood adhesive is shown to have a shear performance greater than the wood-wood shear strength. As a result of the push-out test according to the shape of the shear connector, the shear strength increased linearly with the attachment area. The complete composite behavior between the glued-laminated timber and the steel can be secured.
4,000원
8.
2019.12 구독 인증기관 무료, 개인회원 유료
This paper discusses the influence of transverse reinforcement spacing and support width of concrete wide beam on shear performance. In order to evaluate the shear performance, a total of thirteen specimens were constructed and tested. The transverse reinforcement spacing, the number of legs and support width were considered as variables. From the test results, the shear strength equation of concrete wide beam is proposed for prediction of shear strength of concrete wide beam to consider the transverse reinforcement spacing and support width. It is shown that the proposed equation is able to predict shear strength reasonably well for concrete wide beam.
4,000원
9.
2019.12 구독 인증기관 무료, 개인회원 유료
A stadium roof that uses the pin-jointed spatial truss system has to be designed by taking into account the unstable phenomenon due to the geometrical non-linearity of the long span. This phenomenon is mainly studied in the single-free-node model (SFN) or double-free-node model (DFN). Unlike the simple SFN model, the more complex DFN model has a higher order of characteristic equations, making analysis of the system’s stability complicated. However, various symmetric conditions can allow limited analysis of these problems. Thus, this research looks at the stability of the DFN model which is assumed to be symmetric in shape, and its load and equilibrium state. Its governing system is expressed by nonlinear differential equations to show the double Duffing effect. To investigate the dynamic behavior and characteristics, we normalize the system of the model in terms of space and time. The equilibrium points of the system unloaded or symmetrically loaded are calculated exactly. Furthermore, the stability of these points via the roots of the characteristic equation of a Jacobian matrix are classified.
4,000원
10.
2019.12 구독 인증기관 무료, 개인회원 유료
This study introduces a newly developed PC non-bearing wall system to prevent the damage of RC wall-type apartments that have been heavily damaged by the 2017 Pohang Earthquake. In order to evaluate the performance of the developed PC non-bearing wall system, a static cyclic test is conducted. The prototype of test specimen is from the RC wall-type apartment which has been severely damaged by the 2017 Pohang Earthquake. The specimen with the conventional non-bearing wall system showed the similar damage of RC wall type apartment suffered from the Pohang Earthquake. In case of the specimen with the developed PC non-bearing wall system, cracks and damages were not transmitted between the walls due to the seismic slit and there were almost no cracks in the non-bearing walls. Therefore, the proposed non-bearing wall system, separated from the structural walls, could prevent spreading cracks to bearing walls and make it possible to effectively control damage due to earthquake loads.
4,000원
11.
2019.12 구독 인증기관 무료, 개인회원 유료
When 3D printing is used practically at construction sites, there is a serious lack of studies on the conflict with construction-related laws and expected operational problems. Accordingly, the purpose of this study is to present obstacles and directions for improvement in construction-related laws (Building Act, Construction Technology Promotion Act, Housing Act, Construction Machinery Management Act, etc.) for practical operation of 3D printing. The important results are as follows. Amending existing construction-related laws for 3D printing is irrational and inefficient in terms of structure and material. This study proposed a method of satisfying performance required by laws or standards based on the performance design method presented in existing laws and systems through structure and material performance certification procedure. In addition, inclusion of 3D printing equipment in the Construction Machinery Management Act results in various restrictions such as equipment inspection and certification of machine parts. As such restrictions can block vitalization of 3D printing, a long-term and step-wise approach was suggested.
4,000원
12.
2019.12 구독 인증기관 무료, 개인회원 유료
In this study, the reliability of the analysis is evaluated by comparing the average wind pressure coefficient, RMS wind pressure coefficient and wind pressure spectrum with same condition of wind tunnel test which are calculated in the high-Reynolds number range of 1.2 ×1.06, 2.0.×106 each for the typical curved shape dome structure. And it is examined by the reliability of analysis through Improved delayed detached Eddy Simulation(IDDES), which is one of the hybrid RANS/LES techniques that can analyze the realistic calculation range of high Reynolds number. As a result of the study, it was found that IDDES can be predicted very similar to the wind tunnel test. The distribution pattern of the wind pressure coefficient and wind pressure spectrum showed a similar compared with wind tunnel test.
4,000원
13.
2019.12 구독 인증기관 무료, 개인회원 유료
The cable-based retractable membrane roof makes it impossible to maintain its shape and stiffness during driving process, unlike the hard-type retractable roof. Consequently, monitoring using a relatively simple wireless video transmission device is required. However, since video data has a bigger transmission rating than other monitoring data in terms of the structure velocity or acceleration, there is a need to develop transmission device that is easy to install and entails low maintenance cost. This paper studies on a real-time video transmission system for monitoring the cable-based retractable membrane roof while driving. A video transfer software, using the mobile network, is designed and the embedded system is constructed. Ultimately, the data transmission server is tested. Connecting a trolley to the system allows testing of the validity and efficiency of the developed system through the video data transmitted in the driving process. Result of the test shows that the developed system enables multi-device data transfer with monitoring via the mobile network.
4,000원