This study investigated a bio-tensegrity structural system that combines the characteristics of a general tensegrity structural system with a biological system. The final research objective is to accomplish a changeability for the structural system as like the movement of the natural bio-system. In the study, we present a shape finding procedure for the two stage bio-tensegrity system model inspired by the movement pattern of animal backbone. The proposed system is allowing a dynamic movement by introducing the concept of “saddle” for the variable bio-tensegrity structure. Several shape finding analysis example and results are presented and shows a efficient validation and suitability.
The outrigger damper system is a structural system with excellent lateral resistance when a wind load occurs. However, research on outrigger dampers is still in its infancy. In this study, dynamic response control performance of damper is analyzed according to change of stiffness value and damping value of damper. To do this, a real-scale 3D model of 50 stories has been developed and the artificial wind load has been entered for dynamic analysis. Generally, the larger the damping value, the smaller the stiffness value is, the more effective it is to reduce the maximum displacement and acceleration response. However, the larger the attenuation value as the cost of construction increases, it is necessary to select appropriate stiffness and damping value when applying an outrigger damper.
In this study, TMD(Tuned Mass Damper) is installed in a retractable-roof spatial structure in order to investigate dynamic response characteristics according to mass ratio and installed position of TMD on large spatial structures. The example analytical model is generated based on the Singapore sports hub stadium. Twenty eight analytical models are used to investigate optimal installation position of TMD for the example retractable-roof spatial structure using 4 to 16 TMDs. The mass of one TMD is set up 1% of total mass at the example analytical model. Displacement response ratio of model with TMD is compared with that of base model without TMD. It has been found from numerical simulation that it is more effective to install TMD at the edge of the spatial structure rather than to concentrate the TMD at the center of the spatial structure.
Recently, measuring instruments for SHM of structures had being developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to its absence of triboelectric noise and elimination of the requirement for cumbersome cable. However, the research on the tall buildings with relatively small vibration levels is insufficient. Therefore, in this paper, we used the wireless MEMS sensor and iPad to compare and analyze the vibration measurements of three tall buildings and two towers.
Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from –2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from – 1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.
In current research, it was attempted a preliminary design and evaluation of non-uniform ultra high-strength concrete (UHSC) truss members. UHSC used here has the compressive strength of 180 MPa, the tensile strength of 8 to 20 MPa, and the tensile strain after cracks up to 2%. By the three-dimensional finite element stress analysis as well as strut-tie approach on concrete solid beams, the non-uniform truss shape of UHSC truss was designed with the architectural esthetic concept. In a series of examples, to compare with conventional concrete members, the proposed UHSC truss members have advantages in capabilities of the slender design with minimum weight with high performances under transverse loadings as well as the aesthetically non-uniform design for spatial structures.
Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5–15 story buildings in a city center. The minimum peak wind pressure coefficient was –3.0 at the bottom edges of the front and back of the rooftop signboards and –2.0 along the entire length of the sides . As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.
Stone pagoda structures have continued to be aged due to the combination of various damage factors. However, some studies on nonstructural damage have been carried out, but assessment studies on structural damage have not been done in various ways. Therefore, in this study, structural and nonstructural influencing factors according to the damage types are classified and the damage assessment according to the structural influencing factors affecting the behavior of the stone pagoda structure is performed. In addition, the damage rating classification criteria for each type of structural damages or damage locations are presented, and the damage index is calculated by providing the criteria for the classification of damage according to the degree of damage to which the damage is caused. Therefore, this study can evaluate quantitatively the damage status of stone pagoda structures.
This paper presents the design, analysis, and experimental evaluations of precast reinforced UHPC (ultra high-performance concrete) beams with a new design concept of non-uniform flexural members. With outstanding mechanical properties of UHPC which can develop the compressive strength up to 200MPa, the tensile strengths up to 8~20MPa and the tensile strain up to 1~5%, a non-uniform structural shape of UHPC flexural beams were optimally designed using three-dimensional finite element analysis. The experiments were carried out and compared with the design strength in order to verify the performance of them. Proposed non-uniform UHPC beams were evaluated by a series of three-point beam loading test as well as estimated by design bending and shear strength of members. The newly designed UHPC beams show excellent performances not only in transverse load capacities but also in deformation capacities.
In this paper a systematic numerical analysis is performed to obtain the energy dissipation and re-centering capacities of diagonal steel braced frames subjected to cyclic loading. This diagonal steel bracing systems are fabricated with super-elastic SMA (Shape Memory Alloy) braces in order to develop a recentering seismic resistance system without residual deformation. The three-dimensional nonlinear finite element models are constructed to investigate the horizontal stiffness, drifts and failure modes of the re-centering bracing systems.
The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the cap-type shear connectors with constant intervals. Existing equations for the evaluation of shear connector strength have been investigated on the basis of test results. The reinforcing bars for longitudinal reinforcement and the penetrative bars for transverse reinforcement didn’t have much effect on the shear capacity of the cap-type shear connector. The larger the width of cap-type shear connector was profiled, the greater the shear strength turned. The shear capacities of cap-type shear connectors with constant intervals were evaluated on the basis of push-out test results, and those were possible to be determined with proper safety margin using the Eurocode 4. The slip capacity of cap-type shear connector was shown to exceed the limit value of 6mm for sufficiently ductile behavior.
Following a 5.8 magnitude earthquake on September 12, 2016 in Gyeongju Province, a magnitude 5.4 earthquake occurred in the northern region of Pohang City on November 15, 2017 in South Korea. Only 7.9 % of the building structures are earthquake-resistant, according to the recent survey conducted by the government agencies in October 2017. In this paper, the linear analysis seismic performance evaluation procedure of the existing school structures presented in the revised methodology(Seismic Performance Evaluation Procedure and Rehabilitation Manual for School Facilities) was introduced. In this paper, the linear analysis evaluation procedure presented in the revised methodology was introduced and the seismic performance index of the example structure was evaluated using the linear analysis evaluation procedure. The seismic retrofit was verified by the linear and nonlinear dynamic analyses using Perform 3D. The analysis results show that the dissipated inelastic energy is concentrated on the retrofitted shear wall and the maximum inter-story drift of the stadium model structure with damping system satisfies the requirement of the current code.