Stone pagoda structures have continued to be aged due to the combination of various damage factors. However, some studies on nonstructural damage have been carried out, but assessment studies on structural damage have not been done in various ways. Therefore, in this study, structural and nonstructural influencing factors according to the damage types are classified and the damage assessment according to the structural influencing factors affecting the behavior of the stone pagoda structure is performed. In addition, the damage rating classification criteria for each type of structural damages or damage locations are presented, and the damage index is calculated by providing the criteria for the classification of damage according to the degree of damage to which the damage is caused. Therefore, this study can evaluate quantitatively the damage status of stone pagoda structures.
본 논문에서는 구조건전성모니터링(SHM)시스템이 설치된 케이블교량을 대상으로 장기적인 동적거동 특성을 분석하였다. 3차원 유한요소모델을 사용한 모드해석을 통해 모드변수를 추출하였다. 이를 교량에서 측정된 상시진동신호에 대해 주파수영역에서 분석한 고유진동수와 비교하여 정확한 기저모델이 구축되었음을 알 수 있었다. 지난 5년간의 고유진동수와 온도를 통계분석하여 고유진동수가 온도에 선형 반비례하고 있음을 확인하였고, 이러한 온도효과에 대한 평가를 수행하였다. 또한 상시진동신호를 시간영역에서 TDD기법을 적용하여 모드형상을 추출하였으며, 모드해석 결과와의 비교를 통해 케이블교량에 적용이 가능함을 검증하였다.
서해대교는 국내에 교량구조물에 관한 내진설계가 도입되기 전 설계된 교량으로서 현재 내진설계 규준에 적합하지 않은 종방향철근 및 횡방향 철근이 겹침이음된 중공육각형 단면의 철근콘크리트 기둥으로 이미 시공이 완료된 상태이다. 최근, 지진에 대한 사회적 관심이 대두됨으로서 내진 설계 규준에 적합하지 않은 철근상세를 가지 서해대교 PSM교 교각의 내진성능이 의문시되었다. 따라서, 비내진 철근상세를 가진 서해대교 PSM교 교각의내진성능 평가를 위하여 교각의 축소모형 실험을 수행하였으며, 실험결과 종방향철근 겹침이음이 교각의 전체적인 내진거동에는 큰 영향을 미치지 않으며 기대 이상의 연성을 발휘할 수 있는 것으로 나타났다. 본 논문에서는 축소모형 실험결과에 의한 시험체의 파괴양상, 유효강성, 연성, 응답수 정계수 및 등가점성감쇠비를 분석하였으며, 아울러 가속도변위 응답스펙트럼을 이용하여 서해대교 PSM교 교각의 내진성능을 평가하였다.