        1.
        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the floor construction method of buildings is rapidly being replaced by the steel deck construction method of factory products from the past cast-in-place formwork method in order to shorten construction period, reduce labor costs, and improve constructability. In this study, the bending capacity of a newly developed lattice integrated rib-type deck plate that is economical and constructible was evaluated through a simple beam test. As a result of the experiment, the lattice integrated rib-type deck installed by adding rib to the existing flat deck had excellent initial rigidity and maximum load-bearing ability, confirming the feasibility of practical use. In addition, the test specimen in which the tensile rebar is not integrated with the lattice and deck has very low initial stiffness, which is insufficient to support the load at the construction stage, and new details need to be developed to overcome this.
        4,000원
        2.
        2024.04 구독 인증기관·개인회원 무료
        기존 교량을 일체식 교대 교량과 같이 거동할 수 있도록 교대 흉벽과 상부슬래브를 일체화하는 흉 벽 일체식 교대 교량 공법에 관한 것으로, 교대 흉벽은 뒤채움 토사의 토압을 주요 하중으로 설계되기 때문에 배면부에는 휨보강 철근이 배치되지만 흉벽 일체화에 따른 흉벽 전면부에 온도팽창에 저항하 기에 부족한 철근량을 가지게 된다. 본 실험 연구는 일체화된 흉벽 구조체의 단차부 전면에 부착-정 착방식으로 제작된 FRP 보강체를 사용하여 휨 실험을 수행하고 이를 비교 분석하였다.
        4.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A bending experiment was conducted to verify the structural performance of the U-flange truss hybrid bean using rebars or steel pipes to reinforce the upper compression zone. As a result of evaluating the bending strength of the truss hybrid beam according to the Structural Design Standard (KDS 14 2020: 2022) by introducing the lattice member as a tensile resistance element, the following conclusions were obtained. Considering the lattice element as a tensile resistance element, the nominal bending strength was increased by 38.57 to 47.90 kN.m. As a result of reviewing the experiment as to whether the flexural member has proper ductility, it was found that it is desirable to place appropriate rebars, steel quality plans, and lateral restraints on the upper and lower parts of the hybrid beam to have sufficient ductility ratio.
        4,000원
        5.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A typical low and medium-sized neighborhood living facility in reinforced concrete building secures a high floor and pursues an efficient module plan(long span). Accordingly, research on the development of new hybrid beams that can innovatively reduce labor costs such as on-site installation and assembly while securing strength and rigidity is ongoing. In order to verify the structural performance of the U-flanged truss composite beam with newly developed shape, Experiments with various variables are required. Based on the results, this study is to evaluate the strength of U-flanged truss hybrid beam through the flexural strength of the Korea Design Code and experimental values. It was evaluated that nominal flexural strength was 110% to 135% higher than the experimental value.
        4,000원
        7.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, In order to apply the U-flanged truss hybrid beam to the actual construction site, the structural design of the basic module of the middle and low-rise neighborhood living facilities was performed according to the Korea Design Standard, and the construction cost and construction period were compared with the traditional reinforced concrete structure system. As a result of analyzing the construction cost for the basic module, if the U-flanged truss hybrid beam and D-Deck slab system are used, the construction cost can be reduced by 86% compared to the traditional reinforced concrete structure system. In addition, as a result of analyzing the construction period for a floor area of 1,000m2, using the U-flanged truss hybrid beam and D-Deck slab system can save 2.0days in construction period compared to the traditional reinforced concrete structure system. Therefore, the U-flange truss hybrid beam can secure sufficient economic feasibility compared to the existing reinforced concrete method in terms of cost reduction and shortening of construction period.
        4,000원
        9.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For the practical application of U-flanged Truss Hybrid beams, the flexural capacity of hybrid beams with end reinforcement details using vertical steel plates was verified. The bending test of U-flanged Truss Hybrid beams was performed using the same top chord under the compressive force, but with the thickness of the bottom plate and the amount of tensile reinforcement. The initial stiffness and maximum load of the specimen with tensile reinforcement have a higher value than that of the specimen without tension reinforcement, but the more tensile reinforcement, the greater the load decrease after the maximum load. In the case of the specimen with tensile reinforcement, because the test result value is 76% to 88% when compared with the flexural strength according to Korea Design Code, the safety of the U-flanged Truss Hybrid beam with the same details of the specimens can’t ensure. Therefore, the development of new details is required to ensure that the bottom steel plate and the tensile reinforcement can undergo sufficient tensile deformation.
        4,000원
        11.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The U-flanged truss hybrid beam is a new composite beam made by pouring concrete into the U-flanged truss beam. In this study, an experimental study was performed to verify the shear capacity of U-flanged truss hybrid beams with the newly developed end reinforcement details. For all specimens, the maximum shear strength was determined by shear failure of concrete in the loading point The detail reinforced with stirrups at the end zone can exhibit the greatest shear strength, but the method of reinforcing the end zone using vertical steel plates, which is a relatively easy method to manufacture, is considered to be the most effective detail in terms of shear strength and ductility. Also, in the case of U-flanged truss hybrid beams reinforced with vertical steel plates at the end zone, the shear strength can be evaluated on the safety side by using the Korea Design Standard formula.
        4,000원
        13.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study, the details of delayed buckling of lattice members were developed through reinforcement of the end section, in order to improve structural capacity of U-flanged Truss Steel Beam. To verify the effects of these details, the simple beam experiment was conducted. The maximum capacity of all the specimens were determined by the buckling of the lattice. The vertical reinforced details of the ends with steel plates, rather than the details reinforced with steel bars, are confirmed to be a valid method for enhancing the structural capacity of the U-flanged Truss beam. In addition, U-flanged Truss Steel Beam with reinforced endings with steel plates can exhibit sufficient capacity of the lattice buckling by the formulae according to Korean Building Code (KBC, 2016) and Eurocode 3.
        4,000원
        14.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the continuous cap-type shear connector. Existing formulas for the elevation of shear connector capacity were investigated on the basis of test results. The shear capacities of continuous cap-type shear connectors distinctly declined as the diameters of side-hole in the shear connector increased. The rebars through side-hole for the transverse reinforcement improved the shear capacity of continuous cap-type connector by 20 to 30 percent. It was not feasible to obtain the appropriate capacity values of continuous cap-type shear connectors made of thin steel plate like those of in this study, using the existing formulas. The new formula for reflecting the shear strength of penetrative bars was proposed based on the shear equation of Eurocode 4. The slip capacities of continuous cap-type shear connectors were shown to exceed the limit value of 6mm for the sufficiently ductile behavior.
        4,000원
        15.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars welded on the upper and lower sides. The hybrid beam with U-flanged steel truss is made in the construction site through pouring the concrete, and designated as U-flanged truss hybrid beam. In this study the structural experiments on the 4 hybrid beams with the proposed basic shapes were performed, and the flexural capacities from the tests were compared with those from the theoretical approach. The failure modes of each specimen were quite similar. The peak load was reached with the ductile behavior after yielding, and the failure occurred through the concrete crushing. The considerable increasement of deformation was observed up to the concrete crushing. The composite action of concrete and steel member was considered to be reliable from the behavior of specimens. The flexural strength of hybrid beam has been evaluated exactly using the calculation method applied in the boubly reinforced concrete beam. The placement of additional rebars in the bottom instead of upper side is proposed for the efficient design of U-flanged truss hybrid beam.
        4,000원
        16.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study the structural experiments on the U-flanged truss beams with various shapes of upper flange were performed, and the flexural and shear capacities of U-flanged truss beam in the construction stage were evaluated. The principal test parameters were the shape of upper flange and the alignment space of diagonal lattice bars. In all the test specimens, the peak loads were determined by the buckling of lattice bar regardless of the upper flange shape. The test results have shown that the buckling of lattice bar is very important design factor and there is no need to reinforce the basic u-shaped upper flange. However, the early lattice buckling occurred in the truss beam with upper steel bars because of the insufficient strength and stiffness of upper chord, and the reinforcement in the upper chord is necessary. The formulae of Eurocode 3 (2005) have presented more exact evaluations of lattice buckling load than those of KBC 2016.
        4,000원
        17.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공작물 주차장은 제한된 높이를 갖는 시설물로써, 제한된 층고 내에 합리적 구조가 되도록 계획하는 것이 중요하다. 공작물 주차장은 제한된 층고 내에 주차 통로부(6m)와 주차공간부(5m)를 고려한 11m 전후의 장스팬이 대부분이다. 기존의 합성보는 제한된 층고내에서 충분한 보춤을 확보할 수 없기 때문에, 처짐과 같은 사용성에 대한 문제가 발생한다. 본 연구에서는 박스형 강재보의 상부플랜지를 콘크리트 슬래브의 마감면까지 노출시킨 형상의 합성보를 개발하였다. H형 합성보, U형 합성보, Box형 합성보를 대상으로 2점가력 휨실험을 수행하여, 구조특성을 비교하였다. 그리고 주차장 모듈에 대해 대안설계를 수행하여 경제성과 효율성을 비교평가하였다.
        4,000원
        18.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the cap-type shear connectors with constant intervals. Existing equations for the evaluation of shear connector strength have been investigated on the basis of test results. The reinforcing bars for longitudinal reinforcement and the penetrative bars for transverse reinforcement didn’t have much effect on the shear capacity of the cap-type shear connector. The larger the width of cap-type shear connector was profiled, the greater the shear strength turned. The shear capacities of cap-type shear connectors with constant intervals were evaluated on the basis of push-out test results, and those were possible to be determined with proper safety margin using the Eurocode 4. The slip capacity of cap-type shear connector was shown to exceed the limit value of 6mm for sufficiently ductile behavior.
        4,000원
        19.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The SLIM AU composite beam consists of U-shaped steel plate, A-shaped steel cap and infilled concrete. The bottom steel plate acts as tension bars, and the top steel cap takes roles of shear connector and compression bars in the conventional reinforced concrete section. In this paper the shear strength of this composite beam with closed steel section has been evaluated through the concentrated loading shear experiments. Test results under the symmetrical and asymmetrical loading conditions were compared with the predicted values based on the KBC 2016. The composite beam showed the greater shear strength capacities than those of the theoretical evaluation.
        4,000원
        20.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        SLIM AU(A plus U-shaped) composite beam had been developed for not only reducing the story height in residential and commercial building, but also saving the cost of floor construction. The structural performance and economic feasibility was sufficiently approved by means of structural experiments and analytical studies. Even though fire resistance of the SLIM AU composite beam was evaluated throughout furnace fire test, the fire performance of the composite beam using finite element analysis is not analysed yet. Therefore the predictions of fire resistance simulations with loading as well as temperature distribution of the composite beam are summarized in this paper.
        4,000원