간행물

한국공간구조학회지 KCI 등재 JOURNAL OF THE KOREAN ASSOCIATION FOR AND SPATIAL STRUCTURES

권호리스트/논문검색
이 간행물 논문 검색

권호

제21권 제3호 (2021년 9월) 10

학 술 기 사

3.
2021.09 구독 인증기관 무료, 개인회원 유료
This study develops a new device system for measuring a slope of object with non-adhesive, non-contact and non-face-to-face, namely Inclinometer Slope Laser Measuring (ISLM), that is applicable in the field. This system includes cradle, laser, camera, and computer and the filming and is performed after laser projection at programmed intervals. After measuring the amount of displacement converted to numerical values, these values can then be transferred to the office using the selected data transmission method. The obtained results from the test carried out to verify the reliability of the ISLM system indicated that the ISLM system can measure with accurately level of 0.1mm/Pixel at 1m distance and when increasing the camera resolution, the precision might increase proportionally. Therefore, the proposed measure system may widely apply on-site for various constructions, especially, in the case of object with very high surface temperature where exhibits difficulty to directly measure the adjacent structures. However, due to the sensitive reaction to the illuminance, this method can be applied with caution at times of large changes in illuminance, such as at dawn and at dusk.
4,000원
4.
2021.09 구독 인증기관 무료, 개인회원 유료
An experimental study was carried out to evaluate the shear performance at the interface composed of structural laminates and concrete. The main variables are the number of CLT layers and the shape of the shear connector. The number of CLT layers consisted of 3 and 5 layers. A total of 6 test specimens for shear performance evaluation were prepared in the form of a shear connector, a direct screw type and a vertically embedded type. As a result of the experiment, similar behavior was shown in all specimens, regardless of the number of layers, including direct screw type (SC series) and vertically embedded type (VE series). The behavior at the joint surface was damaged due to the occurrence of initial shear cracks, expansion of shear groove cracks, and splaying at the interface after the maximum load.After the maximum load, the shear strength decreased gradually due to the effect of the shear connector. It can be seen that the shear strength of all specimens is determined by shear and compression stress failure of concrete at the interface of the notch joint.
4,000원
5.
2021.09 구독 인증기관 무료, 개인회원 유료
A tilted tall building is actively constructed as landmark structures around world to date. Because lateral displacement responses of a tilted tall building occurs even by its self-weight, reduction of seismic responses is very important to ensure structural safety. In this study, a smart tuned mass damper (STMD) was applied to the example tilted tall building and its seismic response control performance was investigated. The STMD was composed of magnetorheological (MR) damper and it was installed on the top floor of the example building. Control performance of the STMD mainly depends on the control algorithn. Fuzzy logic controller (FLC) was selected as a control algorithm for the STMD. Because composing fuzzy rules and tuning membership functions of FLC are difficult task, evolutionary optimization algorithm (EOA) was used to develop the FLC. After numerical simulations, it has been seen that the STMD controlled by the EOA-optimized FLC can effectively reduce seismic responses fo the tilted tall building.
4,000원
6.
2021.09 구독 인증기관 무료, 개인회원 유료
As earthquakes continue to occur in Korea in recent years, seismic evaluation and retrofit of existing school buildings have been carried out. Many domestic school buildings were built using or referring to standard drawings. Therefore, if the overall structural characteristics of a school building can be known first based on standard drawings, it can be provided as valuable data for detailed seismic evaluation. For this reason, this study investigated the weak structural components and failure modes by comparing the strength of beams, columns, and joints constituting standard school buildings constructed in the 1980s. The evaluation was performed for different types of standard drawings and different material strengths. The results showed that the joint was mainly the weakest due to the eccentricity, and the failure modes were partially changed depending on the material strength.
4,000원
7.
2021.09 구독 인증기관 무료, 개인회원 유료
In this study, a rocking behavior experiment using a guide plate and a guide channel to prevent lateral deformation of a steel damper was planned. For this purpose, strut I-type specimen I-1 and strut S-type specimen S-1 were prepared. The experimental results were compared with the existing experimental results of SI-260 and SS-260 under the same conditions without the details of lateral deformation prevention in order to evaluate the effect of preventing lateral deformation. The damper with lateral deformation prevention detail was evaluated to have superior strength capacity, deformation capacity, and energy dissipation capacity than the damper without it. Therefore, the lateral deformation prevention detail was evaluated to have a good effect in improving the design capability of the steel damper.
4,000원
8.
2021.09 구독 인증기관 무료, 개인회원 유료
Precast concrete (PC) modules have been increased its use in modular buildings due to their better seismic performance than steel modules. The main issue of the PC module is to ensure structural performance with appropriate connection methods. This study proposed a PC modular beam system for simple construction and improved structural and splicing performance. This modular system consisted of modules with steel plates inserted, and it is easy to construct by bolted connection. The steel plates play the role of tensile rebar and stirrup, which has the advantage of structural performance. The structural performance of the proposed PC modular beam system was evaluated by flexural test on one reinforced concrete (RC) beam specimen consisting of a monolithic, and two PC specimens with the proposed PC modular beam system. The results demonstrated that the proposed PC modular beam system achieved approximately 86% of the structural performance compared to the RC monolithic specimen, with similar ductility of approximately 1.06 fold greater.
4,000원
9.
2021.09 구독 인증기관 무료, 개인회원 유료
In this study, In order to apply the U-flanged truss hybrid beam to the actual construction site, the structural design of the basic module of the middle and low-rise neighborhood living facilities was performed according to the Korea Design Standard, and the construction cost and construction period were compared with the traditional reinforced concrete structure system. As a result of analyzing the construction cost for the basic module, if the U-flanged truss hybrid beam and D-Deck slab system are used, the construction cost can be reduced by 86% compared to the traditional reinforced concrete structure system. In addition, as a result of analyzing the construction period for a floor area of 1,000m2, using the U-flanged truss hybrid beam and D-Deck slab system can save 2.0days in construction period compared to the traditional reinforced concrete structure system. Therefore, the U-flange truss hybrid beam can secure sufficient economic feasibility compared to the existing reinforced concrete method in terms of cost reduction and shortening of construction period.
4,000원
10.
2021.09 구독 인증기관 무료, 개인회원 유료
The purpose of this paper is to understand the key factors for efficient maintenance of rapidly aging facilities. Therefore, the safety inspection/diagnosis reports accumulated in the unstructured data were collected and preprocessed. Then, the analysis was performed using a text mining analysis method. The derived vulnerabilities of tunnel facilities can be used as elements of inspections that take into account the characteristics of individual facilities during regular inspections and daily inspections in the short term. In addition, if detailed specification information and other inspection results(safety, durability, and ease of use) are used for analysis, it provides a stepping stone for supporting preemptive maintenance decision-making in the long term.
4,000원