        1.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Micro-climate measurements and computational fluid analysis were conducted to use it as basic data for the preservation and management of the old house of Kim Myung-kwan, a traditional building that is National Folk Cultural Property No. 26. As a result of the actual measurement, the temperature and humidity are relatively evenly distributed indoors unlike outdoors, but the temperature and humidity vary depending on the time change and the installation location in the outdoors. It was found that the temperature increases after dawn and the temperature varies depending on the installation position around 14:00–15:00, when the temperature becomes the highest. In particular, the temperature was high at the outdoor measurement point adjacent to the building and the fence. As a result of the computational fluid analysis, the temperature was high in the buildings and fences in the old house or in the area adjacent to the building, and it was about 1℃ higher than the surrounding area. In this area, it is judged that the thickening of wood will occur more severely than in other locations, and special preservation management is required.
        4,000원
        2.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5–15 story buildings in a city center. The minimum peak wind pressure coefficient was –3.0 at the bottom edges of the front and back of the rooftop signboards and –2.0 along the entire length of the sides . As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.
        4,000원
        3.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from –2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from – 1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.
        4,000원
        4.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, various building integrated wind power (BIWP) approaches have been used to produce energy by installing wind power generators in high-rise buildings constructed in urban areas. BIWP has advantages in that it does not require support to position the turbine up to the installation height, and the energy produced by the wind turbine can be applied directly to the building. The accurate evaluation of wind speed is important in urban wind power generation. In this study, a wind tunnel test and computational fluid dynamics (CFD) analysis were conducted to evaluate the wind speed for installing wind turbines between buildings. The analysis results showed that the longer the length of the buildings, which had the same height, the larger the wind speed between the two buildings. Furthermore, the narrower the building’s width, the higher the wind velocity; these outcomes are due to the increase in the Venturi effect. In addition, the correlation coefficient between the results of the wind tunnel test and the CFD analysis was higher than 0.8, which is a very high value.
        4,000원
        5.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Meteorological observatories use measuring boards on even ground in open areas to measure the amount of snowfall. However, it is very difficult to evaluate the accurate amount of snowfall because of the effects of the wind. Therefore, this study tried to determine the internal wind flow inside a windbreak fence to identify an area that was not affected by wind in order to measure the snowfall. We performed a computational fluid dynamics analysis, wind tunnel test of the type and height of the windbreak fence, and analyzed the wind flow inside the fence. The results showed that a double windbreak fence was better than a single windbreak fence for reducing the wind velocity. The reduction of the wind velocity was highest in the middle of a windbreak fence with a width of 4 m and a height of 60cm, where the windbreak fences were fixed to the ground.
        4,000원
        6.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper attempted to bridge this gap by identifying the number of flat-plate solar collectors. The characteristics of wind pressure coefficients acting on flat-plate solar collectors which are most widely used were investigated for various wind direction. Findings from this study found that the location where the maximum wind pressure coefficient occurred in the solar collector was the edge of the collector. Regarding the characteristics according to the number of collectors, the paper found that downward wind pressure coefficient of the lower edge of the collector was higher than the upward wind pressure coefficient of the upper edge of the collector in the basic module (1 piece). However, as the number of collectors increases, the upward wind pressure coefficient of the upper edge become higher than the downward wind pressure coefficient of the lower edge. Finally yet important, it was found that the location of the maximum wind pressure coefficient was changed according to the number of solar collectors.
        4,000원
        7.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        There can be diverse causes in the destruction of a large space structure by strong wind such as characteristics of construction materials and changes in internal and external wind pressure of the structure. To evaluate the wind pressure of roof against the large space structure, wind pressure experiment is performed. However, in this wind pressure experiment, peak internal pressure coefficient is set according to the opening of the roof in Korea wind code. In this article, it was tried to identify the change of internal pressure coefficient and the characteristics of wind pressure coefficient acting on the roof by two kinds of opening on the side of the structure with Hyperbolic Paraboloid Spatial Structures roof. When analyzing internal pressure coefficient according to roof shape, it was found that minimum (52%) and maximum (30%~80%) overestimation was made comparing to partial opening type proposed in the current wind load. It is judged that evaluation according to the opening rate of the structure should be made to evaluate the internal pressure coefficient according to load.
        4,000원
        8.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대공간 건축물의 특징 중 경량화 된 지붕 구조 및 재료의 사용으로 인해 지붕면의 손상이나 파괴 등의 피해가 많다. 대규모 경기장의 경우에는 지붕의 구조가 철골 트러스와 인장케이블을 기반으로 테프론이라는 막재료를 사용하여 구조체를 감싸거나 덮는 형태로 많이 설계가 되는데, 특히 이 막재료의 피해가 많으며 심각한 상황이다. 이러한 사례를 통해 대공간 건축물의 지붕에 대한 내풍설계 연구는 아직 미흡한 상태임을 알 수 있다. 본 논문은 쌍곡포물선 대공간구조물의 지붕의 형태에 대한 공기역학적인 특성을 알아보기 위하여 풍압실험과 유체해석을 실시하였다. 실험결과 바람이 불어오는 방향의 지붕 모서리에서 가장 큰 최소피크외압계수가 나타나지만 지붕의 길이방향으로 갈수록 최소피크풍압계수는 감소하고 있었다.
        4,000원
        9.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        축사는 비닐하우스 다음으로 자연재해에 취약한 농촌시설물이다. 축사의 경우 측벽 없이 지붕만 있는 형태가 가장 많이 사용되고 있는데, 태풍이 불면 지붕 전제가 날아가 많은 피해가 발생하는 실정이다. 그래서 농가에서는 태풍피해예방을 위한 측벽에 윈치 커튼설치하여 피해를 예방하고 있는 실정이다. 본 논문에서는 측벽 개방에 따른 축사지붕에 위치별 풍압 계수 분포특성에 대해서 알아보고자 한다. 측벽유무에 관계없이 축사지붕면의 피크외압계수분포에서 풍향각 0˚로 불어오는 방향에 대해서 불리하게 작용하고 있는 것을 알 수 있다. 그러나 측벽의 유무에 따라 피크외압계수가 풍향각과 처마의 길이에 영향을 받는 것을 확인할 수 있었다.
        4,000원
        10.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내 전체 시설원예에서 파이프 골조로 시공된 비닐하우스가 99.2%이며 구조적으로 취약한 단동형 유리온실이 대부분이다. 이에 현재 국내에서 사용하고 있는 단동형 연통형 단동형 3개로 구성된 배치형 비닐하우스의 지붕면에 대한 피크외압계수에 대해서 알아보고자 한다. 실험결과 단동형이 연동형보다 30%정도 큰 피크외압계수로 분포하고 있었다. 배치형 비닐하우스의 지붕면 피크외압계수도 3개동 모두에서 단동형보다 크게 20-30%정도 크게 분포하고 있었다.
        4,000원
        12.
        2007.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        곡선보의 고유진동수를 측정하기 우하여 이론적인 해석과 실험 및 유한요소법해석을 실시하였다. 본 논문에서는 모우드해석을 위한 실험에서 얻어지는 결과로부터 곡선보의 동특성의 하나인 고유진동수를 구하였다 먼저, 이론식을 통해 구조물의 동특성을 파악하고, 유한요소해석과 실험에 의한 결과를 비교 검토하여 구조물의 동적해석에 있어서 모우드해석법의 적용성을 보였다.
        4,000원
        13.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        방풍팬스의 설치에 의한 저층건물 주변의 풍압특성을 분석하기 위하여 풍압실험을 실시하였다. 방풍팬스의 다공율은 0%와 20%을 중심으로 하였다. 방풍팬스와 저층건물의 거리는 1H-9H까지 범위안에서 측정을 하였다. 사용된 풍속은 6m/s로 일정하게 하였다. 저층건물의 측압공 위치는 정면과 측면 후면을 중심으로 총 54개를 측정하였다. 분석결과 다공률 20%일때는 측정거리 1H-3H일 때 다공률 40%일 때는 측정거리 4H-6H일 때 가장 효과적이었다.
        4,000원
        14.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고층건물의 진동응답을 저감시키기 위한 다양한 방법들이 연구되고 있다. 이들 진동응답의 저감 연구는 건물의 외관을 병화 시키는 방법과 건물에 부가감쇠장치를 설치하는 방법들이 있는데 본 논문에서는 고층 건물의 형태의 변화에 다른 진동변위응답의 특성을 파악하고자 한다. 고층건물의 형태변화 중에서도 외관에 테이퍼를 수는 방법을 사용하였다. 기류의 특성은 도심 및 교외지역을 중심으로 풍동실험을 실시하였다.
        4,000원
        15.
        2005.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Serviceability of buildings is affect by excessive acceleration experienced at the top floors in wind storms that may cause discomfort to the occupants. Tuned liquid damper(TLD) and multiple tuned liquid damper(MTLD) are passive control devices that consists of rigid tank filled with liquid to suppress the vibration of structures. This TLD and MTLD are attributable to several potential advantages - low costs; easy to install in existing structures; effective even for small-amplitude vibrations. In this paper, the behavior of TLD and MTLD are investigated analytically and wind tunnel test of high-frequency force balance.
        4,000원
        16.
        2002.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Measurement of fluctuating pressure by tube system is carefully designed due to the organ-pipe resonance. It is necessary to correct the pressure before analysis. The three method for correction the distortion fluctuation pressure short tube length and the frequency response functions and insert a restrictor in the tube to increase the damping. The first method is useful when the tube length is short. In second method, the distorted signal through the tubing transformed into the frequency domain, dividing by transfer function and inverse fourier transforming back into the time domain gives the required pressure signal. In this paper three types of tubing which have different length of 100cm, 150cm, 200cm were experimented the distorted signal and correct the distortion signal