Between the RC and SC structures, the connection method, such as baseplate type(mechanical splice) & noncontact lap splices, was suggested in KEPIC SNG. In previous research, baseplate type using #14bar were developed and their structural integrity was confirmed by the actual bending test. However, the structural integrity of noncontact lap splices using #14bar has not been yet confirmed through experiment. In this study, load-displacement curve of noncontact lap splices FEM model is compared with baseplate type analytical results. This research suggests the possibility of the noncontact lap splice for connection design in case of #14 dowel bar of RC Structure.