This study was performed in the 175 selected child-care facilities in the urban area (Seoul, Suwon, Daejeon, and Busan) and the industrial complex area (Sihwa and Yeosu) to measure of the characteristics of VOCs in the indoor air from August, 2007 to April, 2008. All samples were collected at the indoor and outdoor places to the child-care facilities in spring, summer, and winter seasons using the Tenex absorption trap and were analyzed through the GC/MSD. The mean concentration of VOCs in the 175 child-card facilities showed the highest levels of 73.68 ㎍/m3in the toluene and the lowest levels of 0.28 ㎍/m3in the chlorobenzene. In the concentration of the TVOC, it exceeded 2.5 times more as the indoor air quality guideline in Korea. The result of this study was found that the concentration of VOCs in the child-care facilities in Korea may influenced from the some factors such as the constructional period, traffic density, and ventilation rate. These findings may expected to imply that effective risk management strategies should be applied to minimize the public health effects for children in the child-care facilities in Korea.