논문 상세보기

지하철 터널 미세먼지 제거용 1단 전기집진기의 성능특성 KCI 등재

Performance characteristics of a single-stage electrostatic precipitator for removal of dust in subway tunnels

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/320165
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
실내환경 및 냄새 학회지 (Journal of Odor and Indoor Environment)
한국냄새환경학회 (Korean Society Of Odor Research And Engineering)
초록

A single-stage electrostatic precipitator (ESP) was evaluated in terms of its performance in removing dust in subway tunnels. A wire-to-plate type ESP was tested in a small-scale wind tunnel. The effects of wire-to-wire spacing (2040 mm) and the material connecting wire-to-wire on the performance of ESP were investigated, with varying applied voltage and airflow velocity. A narrower wire-to-wire spacing showed higher collection efficiency at the same applied voltage. Lower electrical resistivity of material connecting wire to wire was more effective. Ozone generation in subway tunnel applications was insignificant.

목차
1. 서 론
 2. 실험 방법
 3. 집진효율 예측
 4. 결과 및 고찰
  4.1 전압-전류 특성 곡선
  4.2 방전선 간격의 영향
  4.3 방전선간 연결 재질의 영향
  4.4 집진성능의 예측값과 측정값의 비교
  4.5 오존 발생
 5. 결 론
 References
저자
  • 김민락(한국과학기술연구원 환경복지연구단, 한양대학교 기계공학부) | Minrak Kim
  • 우상희(한국과학기술연구원 환경복지연구단, 한양대학교 대학원 기계공학부) | Sanghee Woo
  • 김종범(한국과학기술연구원 환경복지연구단, 고려대학교 그린스쿨) | Jong Bum Kim
  • 배귀남(한국과학기술연구원 환경복지연구단, 고려대학교 그린스쿨) | Gwi-Nam Bae Corresponding author