검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 68

        2.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Coffee is the most popular beverage in the world and various pollutants, including volatile organic compounds (VOCs), are emitted from the coffee manufacturing workplace (roasting process). In this study, we analyzed the characteristics of VOCs emissions from roasted Arabica coffee bean powder using a VOCs emission chamber with a PTR-ToF-MS. The emission test was maintained under constant temperature (20 ± 2oC) and humidity (50 ± 5%) conditions. As a result of the emission test, most of the target compounds had a high concentration in the initial period, and decreased emissions as time lapsed. Acetaldehyde showed the highest concentration and was initially 78 ppm during the test period. Acetaldehyde was followed by propionic acid at 61 ppm, propanal at 51 ppm, and isobutanal at 50 ppm. As a result of comparing the occupational exposure limits (OELs) of individual VOC emitted during the coffee roasting process, the OELs of four substances, including acetaldehyde, propionic acid, acetic acid, and pyridine were identified. Of all four substances, only pyridine exceeded the OELs, and the other compounds had levels of 10% to 30% of the OELs.
        4,000원
        5.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        National concerns about air pollution are growing. The importance of indoor air quality is emerging because people live in an indoor environment more than 90% of the day. In particular, the indoor air quality of schools needs to be managed as teenagers are vulnerable to environmental pollution. The government has designated the School Health Act in order to manage indoor air quality in schools. Air purifiers have been operated to improve indoor air quality in the classroom since 2018. In this study, we performed on-site evaluations in some classrooms, and then we proposed a plan for improving the air quality in the classroom. In this study, PM10, PM2.5, and CO2 in classrooms in Chungnam were measured to analyze the effect of air cleaner supply. A portable aerosol spectrometer (PAS, model 1.109, Grimm) and CO2 meter (TES 1370, TES) were used as measuring instruments. Schools A and B exceeded the recommended standards, while school C met the standards. The ratio of PM10, PM2.5 in classrooms A and B was 0.58 and 0.5, respectively. Correlation analysis was performed between indoor and outdoor pollutants to analyze the effects of particulate pollutants present in each classroom. First, the measured concentration of fine particles was classified according to/on the basis of factors that affect/influence the internal environment of the classroom. Then, fine dust concentrations measured at the same time as AQMS were classified with regard to the external factors. The gradients for each classroom were 1.57, 1.63, and 1.54, although there were differences in concentration, but they were relatively similar. It is necessary to develop and disseminate customized air purifiers considering the activity of the occupants of classrooms. It is important to consider the areas in which s tudents breathe when installing air purifiers in the classroom. In addition, follow-up management of air purifiers is an essential element. For efficient operation and management of indoor air quality, it is necessary to develop and disseminate standard manuals for air purifiers. It is proposed that an environmental manager should be deployed in schools to manage environmental issues. Standardization of air purifiers, management guidelines for standard manuals, and field support for environmental sheriffs should be established on a legal basis.
        4,300원
        7.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 해운대 해수욕장의 내습파랑특성과 해빈면적 변화와의 상관성을 파악하였으며, 파랑특성요소를 독립변수로 설정하고 해빈면적 일변화량을 종속변수로 하는 회귀분석을 수행하여 전체 및 세부구간(서측, 중앙, 동측)에 대한 해빈면적 변화량 산출식을 도 출하였다. 도출된 해빈면적 변화량 산출식에 약 10개월의 파랑관측자료를 대입하여 계산된 해빈면적과 실제 관측면적과의 비교를 통해 해빈면적 변화량 산출식의 정확도를 평가하고 해빈면적 변동특성을 분석하였다. 분석 결과, 해빈면적 변화량 산출식의 정확도는 평균 해빈폭 기준 1.5 ~ 2.7 m의 오차를 나타내었으며, 실제 관측면적과의 상관계수는 0.91 ~ 0.94의 분포를 보이며 매우 유사한 해빈면적 변화양상을 나타내었다. 또한, 세부구간별로 해빈면적 변화에 영향을 크게 미치는 파랑특성요소가 서측구간은 파향, 중앙구간은 파고, 동측구간은 파고와 주기인 것을 알 수 있었다. 이를 통해 연안정비사업이 해운대 해수욕장의 해빈면적 변동특성에 미치는 영향 및 연안정비사업의 효과를 파악할 수 있었다. 본 연구에서 도출된 해빈면적 변화량 산출식은 정도 높은 파랑예측자료가 확보될 경우 유의미한 장기간 해빈면적 변화 예측이 가능하므로 연안침식에 대한 선제적 대응 대책 수립 시 의사결정의 근거가 될 수 있는 기초자료 확보에 기여할 수 있을 것으로 기대 된다.
        4,900원
        9.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since 1974, the urban subway has been used as a major form of public transportation in Seoul, Korea. The air quality in the subway environment depends on the introduction of air pollutants from roadway air and its generation is caused by subway operation in the tunnel. In the subway tunnel, PM10 concentration was monitored from March 8 to 15, 2018 and from March 26 to 28, 2018, and compared with concentrations that are routinely monitored at the subway concourse and the nearest roadside air quality monitoring station (RAQMS). Overall PM10 concentration at the concourse was similar to that of the RAQMS. However, PM10 concentration in the tunnel was significantly higher than those of the subway concourse and RAQMS, and showed distinct diurnal variation caused by train operation. The dominant peak concentrations were highly correlated with the number of train operations per hour. The minimum PM10 concentration was observed between 2 am to 5 am when the train was not operated. This was similar to that of the RAQMS. Although the diurnal variation of the PM10 concentration at the concourse is not significant, the overall trend is similar to that in the tunnel.
        4,000원
        11.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The urban expressway is widely used to avoid traffic jams in highly-populated urban areas. However, vehicle exhaust can be easily transported to the neighboring area including residential buildings. In this study, we investigated the transport and penetration of vehicle exhaust into the nearby high-story residential building. Black carbon (BC) and lung deposited surface area (LDSA) concentrations were monitored every 1 min using an aethalometer (AE51, Magee) and a nanoparticle aerosol monitor (AeroTrak 9000, TSI), respectively. For comparison, the measurement was carried out in both the living room and balcony of the apartment from January 18 to January 25, 2016. The CO2 concentration indicated the presence of residents in the living room and transport of vehicle exhaust from the roadway in the balcony. Its diurnal variation showed a significant difference between weekdays and the weekend, implying the different time activity of residents and traffic volume. BC and LDSA concentrations were 1.4±1.5 μg/m3 and 53.9±45.0 μm2/cm3 indoors, and 1.9±1.0 μg/m3, 76.2±34.5 μm2/cm3 outdoors, respectively. The indoor to outdoor concentration ratios range from 0.6 to 0.8, indicating the significant influence of outdoor vehicle exhaust. The highest concentrations of BC and LDSA were observed in the morning rush hours, except for those indoors during the weekend. In particular, the outdoor effect is significant during the morning rush hours. Indoor air quality management is urgently needed for residents living near the urban expressway.
        4,000원
        12.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 해양수산부 연안침식 실태조사에서 운영 중인 해운대 해수욕장 비디오 모니터링 시스템을 이용하여 연안정비 사업 실시 이후의 백사장 면적변화를 분석하였다. 해운대 해수욕장은 연안정비사업을 통한 대규모 양빈이후 계절변동 특성과 함께 해빈 안정화 과정을 거치면서 잘 유지되었으나, 최근 2년간 복수의 태풍 내습에 의하여 해운대 해수욕장의 계절변동특성 및 해빈안정화 양상은 균형을 상실하였으며, 급격한 침식이 발생하였다. 특히, 2018년 태풍 솔릭, 콩레이에 의해 침식된 백사장은 계절변동에 의한 겨울철 해빈면적을 회복하지 못하였으며, 2019년에 내습한 다수의 태풍들로 인하여 해빈면적이 전년 대비 9.5 %(12,607 m2) 감소하였다. 해운대 해빈 전면에서 관측된 파랑자료와 해빈면적자료를 분석한 결과, 계절에 따른 입사파향에 따라 백사장의 서측, 중앙부, 동측의 침퇴적 경 향이 뚜렷이 나타났다. 향후에는 계절변동특성의 둔화와 지속적인 침식경향이 나타나는 원인을 파악하기 위해 잠제 시설물의 마루높이, 기능유지 여부 및 잠제 외부로의 모래유출추적 등 보다 정밀한 모니터링이 필요하다.
        4,000원
        13.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As a series of fundamental researches on the development of an automatic identification monitoring system for fishing gear. Firstly, the study on the installation method of automated identification buoy for the coastal improvement net fishing net with many loss problems on the west coast was carried out. Secondly, the study was conducted find out how to install an automatic identification buoy for coastal gill net which has the highest loss rate among the fisheries. GPS for fishing was used six times in the coastal waters around Seogwipo city in Jeju Island to determine the developmental status and underwater behavior to conduct a field survey. Next, a questionnaire was administered in parallel on the type of loss and the quantity and location of fishing gear to be developed and the water transmitter. In the field experiment, the data collection was possible from a minimum of 13 hours, ten minutes to a maximum of 20 hours and ten minutes using GPS, identifying the development status and underwater behavior of the coastal gillnet fishing gear. The result of the survey showed that the loss of coastal net fishing gear was in the following order: net (27.3%), full fishing gear (24.2%), buoys, and anchors (18.2%). The causes were active algae (50.0%), fish catches (33.3%) and natural disasters (12.5%). To solve this problem, the installation method is to attach one and two electronic buoys to top of each end of the fishing gear, and one underwater transmitter at both ends of the float line connected to the anchor. By identifying and managing abnormal conditions such as damage or loss of fishing gear due to external factors such as potent algae and cutting of fishing gear, loss of fishing gear can be reduced. If the lost fishing gear is found, it will be efficiently collected.
        4,000원
        14.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Many air purifiers have been developed and released with increasing PM. In generally, the performance of air purifiers has been evaluated in the environment chamber by relevant standards. However, as there is a lack of information about air cleaning performance of air purifier in the living area, consumers have difficulty with product selection. In this study, five air purifiers were tested in apartments with different structures. In order to examine the effect of air purifiers, we assumed 3 cases such as inflow of pollutants from outdoors by ventilation, smoking patterns of residents, and cooking methods (e.g., frying fish). The evaluation results showed that the efficiency of air purifier products D and B of the 3-stage configuration (pre-filter + HEPA filter + activity carbon) was the best in most experiments. In the case of the ionizer type E product, the efficiency was very low and, at times, had increased the particulate matter indoors. Considering the cost-performance ratio, it is most reasonable to use an air purifier comprising a pre-filter and a HEPA filter without an additional configuration.
        4,200원
        17.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The urban railway system is a convenient public transportation system, as it carries many people without increasing traffic congestion. However, air quality in urban railway environments is worse than ambient air quality due to the internal location of the source of air pollutants and the isolated space. In this paper, characteristics of particulate matter (PM) pollution in urban railway environments are described from the perspective of diurnal variation, chemical composition and source apportionment of PM. PM concentrations in concourse, platform, passenger cabin, and tunnel are summarized through an analysis of 34 journal articles published in Korea and overseas. This information will be helpful in developing effective policies to reduce PM pollution in urban railway environments.
        4,300원
        1 2 3 4