검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13

        1.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        National concerns about air pollution are growing. The importance of indoor air quality is emerging because people live in an indoor environment more than 90% of the day. In particular, the indoor air quality of schools needs to be managed as teenagers are vulnerable to environmental pollution. The government has designated the School Health Act in order to manage indoor air quality in schools. Air purifiers have been operated to improve indoor air quality in the classroom since 2018. In this study, we performed on-site evaluations in some classrooms, and then we proposed a plan for improving the air quality in the classroom. In this study, PM10, PM2.5, and CO2 in classrooms in Chungnam were measured to analyze the effect of air cleaner supply. A portable aerosol spectrometer (PAS, model 1.109, Grimm) and CO2 meter (TES 1370, TES) were used as measuring instruments. Schools A and B exceeded the recommended standards, while school C met the standards. The ratio of PM10, PM2.5 in classrooms A and B was 0.58 and 0.5, respectively. Correlation analysis was performed between indoor and outdoor pollutants to analyze the effects of particulate pollutants present in each classroom. First, the measured concentration of fine particles was classified according to/on the basis of factors that affect/influence the internal environment of the classroom. Then, fine dust concentrations measured at the same time as AQMS were classified with regard to the external factors. The gradients for each classroom were 1.57, 1.63, and 1.54, although there were differences in concentration, but they were relatively similar. It is necessary to develop and disseminate customized air purifiers considering the activity of the occupants of classrooms. It is important to consider the areas in which s tudents breathe when installing air purifiers in the classroom. In addition, follow-up management of air purifiers is an essential element. For efficient operation and management of indoor air quality, it is necessary to develop and disseminate standard manuals for air purifiers. It is proposed that an environmental manager should be deployed in schools to manage environmental issues. Standardization of air purifiers, management guidelines for standard manuals, and field support for environmental sheriffs should be established on a legal basis.
        4,300원
        2.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서 흰목이버섯의 추출조건별 추출수율과 기능성 성분의 함량을 비교하여 최적 추출조건을 분석하였으며, 모든 분석에서 R²이 0.9331~0.9462로 유의성을 보이는 것을 확인하였다. 각 독립변수에 따른 추출수율과 ergothioneine, β-glucan 성분을 분석한 결과 추출수율은 추출온도와 추출시료농도에 반비례했으며, 추출시간에는 큰 영향이 없었다. Ergothioneine 성분은 온도가 증가할수록 증가하며, 추출시간은 4.33 h가 가장 높았고 시료량에 큰 영향이 없었다. β-glucan 성분은 온도가 증가할수록 감소했으며, 추출시간에 큰 영향이 없었고 시료량이 21.2 mg/mL에서 가장 높았다. 모든 종속변수의 최대 독립변수는 온도 60 o C, 추출시간 4.33 h, 추출시료농도 16.6 mg/mL에서 추출수율 24.9%, ergothioneine 성분함량 66.8 ug/g, β-glucan 성분함량 34.9 g/100 g으로 나타났다.
        4,000원
        3.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전 세계 90 %의 인구가 WHO의 연평균 미세먼지 노출 기준(10 ㎍/㎥)을 초과한 공기를 흡입하고 있다. 전 세계적으로 육상뿐 만 아니라 해양에서 발생하는 질소산화물에 대한 규제를 통해 2차 오염물질, 초미세먼지 저감에 대해 노력하고 있으며 국내에서는 선박에서 미세먼지 발생의 주요한 원인인 황 함유량 저감과 환경친화적 선박의 개발 및 보급 등을 통해 깨끗한 해양환경 조성을 위한 노력을 하고 있다. 디젤엔진 유해 배출가스 저감을 위한 기술 중 압력 손실이 적고 높은 집진 효율 및 NOx의 제거와 유지 관리의 장점이 많은 전기 집진기의 수요와 중요성이 증가하고 있다. 본 연구는 총톤수 999톤급 선박의 2,427 kW 선박용 디젤엔진의 미세먼지 저감을 목적으로 개발된 전기 집진기를 예지보전단계에서 고장모드영향분석을 통해 장비 품질을 높여 선박 내에서의 내구연한을 높이고자 위험 우선순위 도출하였다. 위험 우선순위는 고장모드 241(poor dust capture efficiency)이 RPN 180으로 가장 높았다. Collecting electrode 에서 가장 많은 고위험 고장모드를 검출하여 집중관리 부품으로 관리해야 할 필요가 있었으며 원인으로 진동과 핀 풀림으로 인한 유 격 불량이 가장 많이 검출되었다. 핀 풀림 역시 근본적으로는 선체 또는 장비에서 발생하는 진동이 원인이 되어 발생할 수 있는 사항이기 때문에 핀 풀림이 발생하는 개소에 보완이 필요하겠다.
        4,000원
        4.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since 1974, the urban subway has been used as a major form of public transportation in Seoul, Korea. The air quality in the subway environment depends on the introduction of air pollutants from roadway air and its generation is caused by subway operation in the tunnel. In the subway tunnel, PM10 concentration was monitored from March 8 to 15, 2018 and from March 26 to 28, 2018, and compared with concentrations that are routinely monitored at the subway concourse and the nearest roadside air quality monitoring station (RAQMS). Overall PM10 concentration at the concourse was similar to that of the RAQMS. However, PM10 concentration in the tunnel was significantly higher than those of the subway concourse and RAQMS, and showed distinct diurnal variation caused by train operation. The dominant peak concentrations were highly correlated with the number of train operations per hour. The minimum PM10 concentration was observed between 2 am to 5 am when the train was not operated. This was similar to that of the RAQMS. Although the diurnal variation of the PM10 concentration at the concourse is not significant, the overall trend is similar to that in the tunnel.
        4,000원
        5.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was designed to evaluate the improvement in exercise endurance by Hovenia dulcis fruit hot water extract (HDWE) for the potential application as a functional food material. The effect was based on the evaluation of the forced-swimming capacity and changes in biochemical parameters in mice. Six-week-old mice were classified into four groups based on a randomized block design: the negative control group, the HDWE 50 mg/kg body weight group, the HDWE 200 mg/kg body weight group, and the 1-octacosanol 50 mg/kg body weight group (n=8 mice per group). The swimming exercise time in the HDWE-50 group was increased at 545±43 sec compared to the control group at 263±28 sec. The HDWE-200 fatigue indicators, lactate acid and ammonia content, decreased to 4.99±0.33 mg/mL and 0.63±0.05 mg/mL, respectively. In addition, the content of glycogen in the liver and muscle tended to increase in the group administered HDWE but was not significant. Likewise, the LDH and glucose contents were increased compared to the control group. The muscle damage indicators ALT (52.7±2.6 U/L) and AST (42.5±5.2 U/L) tended to decrease compared to the control group (76.4±10.2 U/L).
        4,000원
        6.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the antioxidant properties of the Radix isatidis extract and the effect of substituting it with sodium nitrite (SN) in a pork patty. The antioxidant activity of the Radix isatidis water extract (RIWE) was compared to those of the methanol and chloroform extracts (RIME and RICE, respectively). Patties were prepared with five different treatments: (1) a control with no RIWE and SN, (2) T1 with 150 ppm SN, (3) T2 with 100 ppm SN + 0.1% RIWE, (4) T3 with 50 ppm SN + 0.3% RIWE, and (5) T4 with 0.5% RIWE. They were used to compare the oxidation stability for 12 days at 4℃. The extraction yield of RIWE was 3.2 and 18.7 times higher (p<0.05) than those of RIME and RICE, respectively, but RIWE had the lowest (p<0.05) 1,1`-diphenyl-2-picrylhydrazyl radical scavenging activity, superoxide dismutase-like activity, and total reducing ability. Patties with RIWE and SN exhibited lower (p<0.05) pH values after 12 days, compared to the control. After 4 days, the 2-thiobarbituric acid reactive substances content was lower (p<0.05) in T1, T2, T3, and T4 than in the control. The oxidation-reduction potential value was the lowest (p<0.05) in T3 and T4 after 4 days (p<0.05). T1, T2, T3, and T4 had a lower (p<0.05) volatile basic nitrogen content after 12 days, compared to the control. These findings suggest that RIWE has an antioxidant effect similar to that of SN, but further research on its antimicrobial effect may be required to determine if it is a good substitute for SN.
        4,200원
        8.
        2015.07 KCI 등재 서비스 종료(열람 제한)
        In 2013, International Agency for Research on Cancer (IARC) concluded that outdoor air pollution is carcinogenic to humans, with the particulate matter component of air pollution most closely associated with sufficient evidence of increased cancer incidence by exposure to particulate matter component of air pollution. Motor vehicles are one of a major emission sources of fine particle (PM2.5) in urban areas. A large number of epidemiological studies have reported a positive association of morbidity or mortality with distance from the roadside. We conducted this study to assess the association of PM2.5 concentrations measured at roadside hotspots with those at adjacent residential sites using real-time PM2.5 monitors. We conducted real-time PM2.5 measurements for rush hour periods (08:00∼10:00 and 18:00∼20:00) at 9 roadside air monitoring Hotspot sites in metropolitan Seoul over 3 weeks from October 1 to 21, 2013. Simultaneous measurements were conducted in residential sites within a 100 m radius from each roadside air monitoring site. A SidePak AM510 was used for the real-time PM2.5 measurements. Medians of roadside PM2.5 concentrations ranged from 9.8 μg/m3 to 38.3 μg/m3, while corresponding median values at adjacent residential sites ranged from 4.4 μg/m3 to 37.3 μg/m3. PM2.5 concentrations of residential sites were 0.97 times of hotspot roadside sites. Distributions of PM2.5 concentrations in roadside and residential areas were also very similar. Real-time PM2.5 concentrations at residential sites, (100 m adjacent), showed similar levels to those at roadside sites. Increasing the distance between roadside and residential sites, if needed, should be considered to protect urban resident populations from PM2.5 emitted by traffic related sources.
        9.
        2014.08 KCI 등재 서비스 종료(열람 제한)
        본 연구에서 Phantom에 고 밀도 물질이 삽입 된 CT 영상을 재구성 하여 방사선 치료 계획 시 선량 분포에 대한 평가를 하고자 하였다. Gammex 467 Tissue Characterization Phantom을 사용하여 인체 조직과 유사한 영상을 획득하였고 Titanium을 삽입하여 금속물로 인한 인공허상을 발생시켜 영상을 획득하였다. 획득한 영상은 Metal Artifact Reduction for Orthopedic Implants (O-MAR)를 이용하여 영상을 재구성 하였고 전산화 치료계획 시스템을 이용하여 체적을 분석 하고 선량 분포를 추출하였다. MapCHECK™을 이용하여 선형가속기의 광자선 선량 분포를 측정하여 계획한 선량 분포와 비교 분석 하였다. 비교 분석 결과 Titanium으로 인한 인공허상이 발생 되었을 때 O-MAR를 적용한 체적은 BR-12 Breast는 16.8 % 그리고 LV 1 Liver는 40.2 % 증가하였고 선량 분포는 O-MAR를 적용하기 전의 선량 분포 보다 1.4 에서 1.6 % 높게 나타났다. 결론적으로 금속물로 발생된 인공허상 O-MAR를 적용하여 가능한 제거하고 치료계획에 이용해야 오류를 줄일 수 있을 것으로 사료된다.
        10.
        2014.06 KCI 등재 서비스 종료(열람 제한)
        본 연구는 양성자 치료를 시행하고 있는 수모세포종 환자의 양성자 치료 시 환자들의 Skin에서 홍반이나 피부염이 발생하는 경우가 빈번하여 Phantom에서 실제 환자와 동일한 치료계획 후 생체 내 선량측정 검출기(In-vivo dosimetry)로 사용되는 열 형광선량계(Thermo-luminescence Dosimeter, TLD)와 EBT3 Film으로 실제선량을 조사측정한다. 측정된 선량값을 치료계획 된 피부선량과 비교 분석하여 양성자 치료 시 임상적으로 피부선량 측정 사용에 유용성이 있는지 알아보고자 한다. Phantom을 수모세포종의 전뇌척수치료(Cranio-spinal irradiation, CSI) Set-up position으로 위치하여 Brain에서부터 Pelvis까지 CT촬영하고 양성자 치료계획 후 치료실에서 디지털 영상 포지셔닝 시스템(Digital Imaging Positioning System, DIPS)을 이용하여 정확하게 치료 Isocenter지점을 맞춘다. 양성자 빔이 들어가는 5부위의 치료 Isocenter 지점과 CT촬영 시 Phantom에 표시한 Marker 2부위, 모두 7지점에 미리 교정을 마친 열 형광선량계와 EBT3 Film을 교차해가면서 위치하여 붙이고 치료 계획된 양성자 빔을 각각 10회씩 조사한다. 10회 반복 측정하여 얻은 값을 평균산출하여 치료계획 시스템 에서 측정된 Skin Dose와 비교 분석한 결과, 측정위치의 어려움이 있는 정확한 측정이 결여된 한 지점을 제외한 나머지 6지점의 측정 선량값은 열 형광선량계와 EBT3 Film 모두 절대 선량값과 ±2%이내의 분포를 보였다. 결론적으로, 본 연구에서는 국내 최초의 양성자 치료에서 Enterance skin dose 측정을 위한 In-vivo dosimetry로 열 형광선량계와 EBT3 Film의 임상적인 유용성을 확인하였다.
        11.
        2011.06 KCI 등재 서비스 종료(열람 제한)
        담낭 결석 환자 중 MRCP를 시행한 환자를 대상으로 SPIO 제제의 조영제를 경구 주입 전, 후를 정량적으로 비교 분석하여 그 유용성을 알아보고자 하였다. 2009년 01월부터 2010년 02월까지 담석증을 보이는 환자 36명을 대상으로 SPIO를 경구 투입한 그룹과 투입하지 않은 그룹으로 나누어 1.5T MR scanner를 사용하여 호흡 정지 기법과 호흡 유 발 기법을 이용한 T2강조 영상을 획득 하였다. 측정 부위는 호흡 정지 기법을 이용한 T2강조 영상에서는 담낭의 중앙 부위와 주위 조직의 측정을 위해 담낭 중앙을 기준으로 전, 후로 각각 15mm 떨어진 부위에 위치시켰으며 호흡 유발 기법을 이용한 T2강조 영상에서는 담낭의 중앙 부위와 간의 5,6 구역에 위치시켰다. 실험에 대한 정량적 분석방법으 로 두 그룹에서 관심영역의 신호대 잡음비를 구하고 평균화 하였으며 담낭의 신호대 잡음비를 기준으로 각각 관심영역 의 대조도대 잡음비를 구하고 평균화 하여 두 그룹 간에 수치를 비교 분석하였다. 두 그룹에서의 대조도대 잡음비는 투입한 그룹에서 높은 대조도대 잡음비를 보였다.
        12.
        2011.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 LVEF값이 40% 미만인 환자와 정상인 환자의 심장 박동 수를 비교 분석하여 CCTA 검사 프로토콜의 최 적화를 통한 양질의 영상, 환자피폭과 재 검률을 최소화시키기 위함이다. 각 심장박동수와 LVEF에 관계에서 LVEF가 40%이하가 될 때 true 100HU에 도달하는 시간이 오래 걸림을 알 수 있다. 그러므로, 40% 미만인 환자들에서 Premonitoring deay를 설정 할 때 5초정도 더 주어도 됨을 알 수 있었다. 조 영제는 Scan time x 4cc + 30cc의 용량을 4cc/sec속도로 주입한 후 이어서 Saline은 모든 환자에게 40cc를 4cc/sec속 도로 추가 주입하였으며, 40% 미만에서는 HR이 80이상을 제외하고는 큰 차이를 보이는 것 을 알 수 있다. 또한, 40% 미만에서는 조영제가 true 100HU에 도달하여 Scan을 시작 할 때 시간 차이가 커 조영제가 이미 Left ventricle에서 Wash-out 됐음을 예측 할 수 있었다. 40%이상의 LVEF와 정상 이하의 LVEF는 검사 도중 많은 차이를 가지고 있다. 낮은 LVEF 환자에게서 검사를 시작 할 경우. 따라서, 조영제 주입 프로토콜은 LVEF에 따라서 CCTA에 결정되어져야 한다. 그리고 우리가 낮은 LVEF에 따라 검사 실패를 감소시켜야 하기 때문에 낮은 LVEF의 경우에는 일반적 Pitch 보다 낮은 Pitch가 사용되어져야 한다.
        13.
        2011.02 KCI 등재 서비스 종료(열람 제한)
        전이성 척추암 환자를 대상으로 1.5 T MR 기기에서 조영제 주입 전⦁후 확산강조영상에서 전이가 된 요추의 신호 대 잡음비, 대조도대 잡음비, 현성 확산 계수가 어떤 변화를 나타내는지 알아보고자 하였다. 영상의 정량적 분석에서는 전이성 척추암 그룹의 경우 조영제 주입 전 확산강조영상에서 전이성 척추암이 있는 부 위와 척추암이 있는 부위의 위, 아래 척추등 세 부위의 신호대 잡음비는 척추암이 있는 부위에서 낮게 나타났으며 조 영제 주입 후 확산강조영상에서는 조영제 주입 전보다 세 부위 모두 신호대 잡음비가 상대적으로 증가하였으며 척추암 이 있는 부위의 위, 아래 척추등 두 부위 에서는 대조도대 잡음비가 상대적으로 증가했다. ADC map영상에서는 조영제 주입 전에서 신호대 잡음비는 척추암이 있는 부위에서 높게 나타났으며 조영제 주입 후에서는 조영제 주입 전보다 전 이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추등 세 부위 모두 신호대 잡음비가 상대적으로 감소했 다. ADC map영상에서의 현성 확산 계수는 조영제 주입 전에서 현성 확산 계수는 척추암이 있는 부위에서 낮게 나타 났으며 조영제 주입 후에서는 주입 전보다 세 부위 모두 현성 확산 계수가 상대적으로 감소했다. 정상 그룹의 경우 확 산강조영상에서 요추체 3, 4, 5번 세 부위 모두 신호대 잡음비가 상대적으로 증가했고 ADC map영상에서는 조영제 주입 후 확산강조영상에서 세 부위 모두 신호대 잡음비가 상대적으로 감소했다. ADC map영상에서의 현성 확산 계수 는 세 부위 모두 현성 확산 계수가 상대적으로 감소했다. 영상의 정성적 분석에서 조영제 주입 후 확산강조영상에서 전이성 척추암이 있는 부위의 신호강도가 증가하였고 ADC map영상에서는 신호강도가 감소하였다. 조영제 주입 후 확산강조영상에서 전이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추 등 세 부위 모두 신호대 잡음비와 대조도대 잡음비가 증가하고 현성확산계수가 감소하는 결과를 얻었고 조영제 주입 후 확산강조영 상이 여러 가지 척추질환으로의 적용에 도움을 줄 것이라 사료된다.