This paper provides the flexural test results of steel fiber reinforced concrete (SFRC) prisms with different aspect ratios of steel fibers (60 and 67). All mixtures have specific compressive strength of 40 MPa and steel fiber volume fraction of 0.75%. According to ASTM C 1609 and EN-14651, SFRC prisms with 150×150×550 mm were made and tested under bending loading. Test results indicated that the aspect ratio of hooked-end steel fibers has insignificant effect on the first-cracking strength and flexural behavior of SFRC prisms.